scholarly journals A noval dynamic calibration approach for current-steering DACs

Author(s):  
Chao Su ◽  
Xin Dai ◽  
R.L. Geiger
Sensors ◽  
2022 ◽  
Vol 22 (1) ◽  
pp. 369
Author(s):  
Shih-Hong Chio

A plane-based dynamic calibration method had been proposed by the previous study for the GeoSLAM ZEB Horizon handheld LiDAR scanner. Only one preliminary test was presented. Therefore, three datasets in a calibration field were collected in this study on different dates and at different times on the same date to investigate the efficiency of the proposed calibration approach and calibration results. The calibration results for these three datasets showed that all average residuals were closer to 0, and all a posterior unit weight standard deviations of the adjustment were also significantly reduced after calibration. Moreover, the RMSE (root mean square error) of the check planes was improved by about an average of 32.61%, 28.44%, and 14.7%, respectively, for the three datasets. The improvement was highly correlated with the quality of the calibration data. The RMSE differences of all check planes using calibration data collected on different dates and at different times on the same date for calibration was about 1–2 cm and less than 1 mm, respectively. There was no difference in the calibration results, demonstrating the efficiency of the proposed calibration approach and the calibration results during the two different dates.


2020 ◽  
Vol 2020 (1) ◽  
pp. 100-104
Author(s):  
Hakki Can Karaimer ◽  
Rang Nguyen

Colorimetric calibration computes the necessary color space transformation to map a camera's device-specific color space to a device-independent perceptual color space. Color calibration is most commonly performed by imaging a color rendition chart with a fixed number of color patches with known colorimetric values (e. g., CIE XYZ values). The color space transformation is estimated based on the correspondences between the camera's image and the chart's colors. We present a new approach to colorimetric calibration that does not require explicit color correspondences. Our approach computes a color space transformation by aligning the color distributions of the captured image to the known distribution of a calibration chart containing thousands of colors. We show that a histogram-based colorimetric calibration approach provides results that are onpar with the traditional patch-based method without the need to establish correspondences.


Author(s):  
Jorge Pérez Bailón ◽  
Jaime Ramírez-Angulo ◽  
Belén Calvo ◽  
Nicolás Medrano

This paper presents a Variable Gain Amplifier (VGA) designed in a 0.18 μm CMOS process to operate in an impedance sensing interface. Based on a transconductance-transimpedance (TC-TI) approach with intermediate analog-controlled current steering, it exhibits a gain ranging from 5 dB to 38 dB with a constant bandwidth around 318 kHz, a power consumption of 15.5 μW at a 1.8 V supply and an active area of 0.021 mm2.


Sign in / Sign up

Export Citation Format

Share Document