Reducing the Sampling Rate of Biochemical Measurements Using Fast-Scan Cyclic Voltammetry for In Vivo Applications

2014 ◽  
Vol 14 (9) ◽  
pp. 2975-2980 ◽  
Author(s):  
Alison N. Amos ◽  
James G. Roberts ◽  
Lingjiao Qi ◽  
Leslie A. Sombers ◽  
Gregory S. McCarty
Author(s):  
Monica M. Arnold ◽  
Lauren M. Burgeno ◽  
Paul E. M. Phillips

Gaining insight into the mechanisms by which neural transmission governs behavior remains a central goal of behavioral neuroscience. Multiple applications exist for monitoring neurotransmission during behavior, including fast-scan cyclic voltammetry (FSCV). This technique is an electrochemical detection method that can be used to monitor subsecond changes in concentrations of electroactive molecules such as neurotransmitters. In this technique, a triangular waveform voltage is applied to a carbon fiber electrode implanted into a selected brain region. During each waveform application, specific molecules in the vicinity of the electrode will undergo electrolysis and produce a current, which can be detected by the electrode. In order to monitor subsecond changes in neurotransmitter release, waveform application is repeated every 100 ms, yielding a 10 Hz sampling rate. This chapter describes the fundamental principles behind FSCV and the basic instrumentation required, using as an example system the detection of in vivo phasic dopamine changes in freely-moving animals over the course of long-term experiments. We explain step-by-step, how to construct and surgically implant a carbon fiber electrode that can readily detect phasic neurotransmitter fluctuations and that remains sensitive over multiple recordings across months. Also included are the basic steps for recording FSCV during behavioral experiments and how to process voltammetric data in which signaling is time-locked to behavioral events of interest. Together, information in this chapter provides a foundation of FSCV theory and practice that can be applied to the assembly of an FSCV system and execution of in vivo experiments.


2019 ◽  
Vol 13 ◽  
Author(s):  
Rachel A. Saylor ◽  
Melinda Hersey ◽  
Alyssa West ◽  
Anna Marie Buchanan ◽  
Shane N. Berger ◽  
...  

2020 ◽  
Author(s):  
Elizabeth N. Holly ◽  
M. Felicia Davatolhagh ◽  
Rodrigo A. España ◽  
Marc V. Fuccillo

Low-threshold spiking interneurons (LTSIs) in the dorsomedial striatum are potent modulators of goal-directed learning. Here, we uncover a novel function for LTSIs in locally and directly gating striatal dopamine, using in vitro fast scan cyclic voltammetry as well as in vivo GRAB-DA sensor imaging and pharmacology during operant learning. We demonstrate that LTSIs, acting via GABAB signaling, attenuate dopamine release, thereby serving as local coordinators of striatal plasticity.


2019 ◽  
Vol 13 ◽  
Author(s):  
Rachel A. Saylor ◽  
Melinda Hersey ◽  
Alyssa West ◽  
Anna Marie Buchanan ◽  
Shane N. Berger ◽  
...  

Micromachines ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 494 ◽  
Author(s):  
Evan Nicolai ◽  
Nicholas Michelson ◽  
Megan Settell ◽  
Seth Hara ◽  
James Trevathan ◽  
...  

Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.


2009 ◽  
Vol 111 (4) ◽  
pp. 712-723 ◽  
Author(s):  
Jonathan M. Bledsoe ◽  
Christopher J. Kimble ◽  
Daniel P. Covey ◽  
Charles D. Blaha ◽  
Filippo Agnesi ◽  
...  

Object Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. Methods The FSCV study consisted of a triangle wave scanned between −0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 μm) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by ~ 100 μm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. Results The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus–connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. Conclusions Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.


2016 ◽  
Vol 136 (6) ◽  
pp. 1270-1283 ◽  
Author(s):  
Rashed Harun ◽  
Kristin M. Hare ◽  
Elizabeth M. Brough ◽  
Miranda J. Munoz ◽  
Christine M. Grassi ◽  
...  

2017 ◽  
Vol 8 (2) ◽  
pp. 221-234 ◽  
Author(s):  
Nathan T. Rodeberg ◽  
Stefan G. Sandberg ◽  
Justin A. Johnson ◽  
Paul E. M. Phillips ◽  
R. Mark Wightman