Recent Advancements in the Development of Sensors for the Structural Health Monitoring (SHM) at High-Temperature Environment: A Review

2021 ◽  
pp. 1-1
Author(s):  
Chandan Dutta ◽  
Jayendra Kumar ◽  
Tarun Kumar Das ◽  
Sarmishtha Palit Sagar
2007 ◽  
Author(s):  
Richard J. Black ◽  
Kelvin Chau ◽  
George Chen ◽  
Behzad Moslehi ◽  
Levy Oblea ◽  
...  

Author(s):  
Mohsen Ghabdian ◽  
Seyed BB Aval ◽  
Mohammad Noori ◽  
Wael A Altabey

An important and critical area within the broad domain of structural health monitoring, as related to reinforced civil and mechanical structures, is the assessment of creep, shrinkage, and high-temperature effects on reliability and serviceability. Unfortunately, the monitoring and impact of these inherent mechanical characteristics and behaviors, and subsequent impact on serviceability, have rarely been considered in the literature in structural health monitoring. In this paper, the microprestress-solidification creep theory for beams is generalized for the simultaneous effect of linear/nonlinear creep, shrinkage, and high temperature in a reliability framework. This study conducts a systematic time-dependent procedure for the reliability analysis of structures using a powerful nanoscale method. It must be noted that this paper aims to extend the previously developed microprestress-solidification method in a health monitoring reliability-based framework with a close look at a nonlinear creep, parameters affecting creep, and long-time high temperature. A finite element approach is proposed where creep, shrinkage, temperature, and cracking are considered using strain splitting theory. First, the model performance was evaluated by comparing the results with the experimental test available in the literature in the case of creep and shrinkage. Then, the simultaneous effect of creep, shrinkage, and temperature was compared with experimental results obtained by the authors. Reliability analysis was applied to reinforced concrete beams subjected to sustained gravity loading and uniform temperature history in order to calculate exceedance probability in the serviceability limit state. It was found that the exceedance probability of reinforced concrete beams was dependent on the shear span-to-depth ratio. In the serviceability limit state, exceedance probabilities of 0.012 and 0.157 were calculated for the span-to-depth ratios of 1 and 5, respectively. In addition, it was shown that temperature plays an important role in the reliability of reinforced concrete beams. A 4.27-fold increase was observed in the case of moderate to high temperature. Finally, for three different load levels of 40%, 70%, and 80%, the exceedance probabilities were 0.156, 0.328, and 0.527, respectively, suggesting that load level is another key parameter affecting the reliability of reinforced concrete beams. It is thus concluded these fundamental phenomenological studies should be further considered as part of the broad field of structural health monitoring.


2011 ◽  
Author(s):  
A. Baba ◽  
C. T. Searfass ◽  
B. R. Tittmann ◽  
Donald O. Thompson ◽  
Dale E. Chimenti

Sensors ◽  
2020 ◽  
Vol 20 (15) ◽  
pp. 4328
Author(s):  
Minsu Kim ◽  
Insol Hwang ◽  
Minho Seong ◽  
Jaemook Choi ◽  
Myunggun Kim ◽  
...  

A variety of sensor systems have been developed to monitor the structural health status of buildings and infrastructures. However, most sensor systems for structural health monitoring (SHM) are difficult to use in extreme conditions, such as a fire situation, because of their vulnerability to high temperature and physical shocks, as well as time-consuming installation process. Here, we present a smart ball sensor (SBS) that can be immediately installed on surfaces of structures, stably measure vital SHM data in real time and wirelessly transmit the data in a high-temperature fire situation. The smart ball sensor mainly consists of sensor and data transmission module, heat insulator and adhesive module. With the integrated device configuration, the SBS can be strongly attached to the target surface with maximum adhesion force of 233.7-N and stably detect acceleration and temperature of the structure without damaging the key modules of the systems even at high temperatures of up to 500 °C while ensuring wireless transmission of the data. Field tests for a model pre-engineered building (PEB) structure demonstrate the validity of the smart ball sensor as an instantly deployable, high-temperature SHM system. This SBS can be used for SHM of a wider variety of structures and buildings beyond PEB structures.


Sign in / Sign up

Export Citation Format

Share Document