Performance at Cryogenic Temperatures of an Ultra Low Noise CMOS Front-end for Fano-limited X-ray Spectroscopy

Author(s):  
C. Liu ◽  
A. Castoldi ◽  
G. Bertuccio ◽  
M. Gandola ◽  
M. Sammartini ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2662
Author(s):  
José A. López-Pérez ◽  
Félix Tercero-Martínez ◽  
José M. Serna-Puente ◽  
Beatriz Vaquero-Jiménez ◽  
María Patino-Esteban ◽  
...  

This paper shows a simultaneous tri-band (S: 2.2–2.7 GHz, X: 7.5–9 GHz and Ka: 28–33 GHz) low-noise cryogenic receiver for geodetic Very Long Baseline Interferometry (geo-VLBI) which has been developed at Yebes Observatory laboratories in Spain. A special feature is that the whole receiver front-end is fully coolable down to cryogenic temperatures to minimize receiver noise. It was installed in the first radio telescope of the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE) project, which is located in Yebes Observatory, in the frame of the VLBI Global Observing System (VGOS). After this, the receiver was borrowed by the Norwegian Mapping Autorithy (NMA) for the commissioning of two VGOS radiotelescopes in Svalbard (Norway). A second identical receiver was built for the Ishioka VGOS station of the Geospatial Information Authority (GSI) of Japan, and a third one for the second RAEGE VGOS station, located in Santa María (Açores Archipelago, Portugal). The average receiver noise temperatures are 21, 23, and 25 Kelvin and the measured antenna efficiencies are 70%, 75%, and 60% in S-band, X-band, and Ka-band, respectively.


2003 ◽  
Vol 50 (3) ◽  
pp. 723-728 ◽  
Author(s):  
G. Bertuccio ◽  
R. Casiraghi ◽  
D. Maiocchi ◽  
A. Owens ◽  
M. Bavdaz ◽  
...  

1993 ◽  
Vol 302 ◽  
Author(s):  
G. Bertuccio ◽  
P. Rehak ◽  
D.M. Xi

ABSTRACTA new circuital configuration for the charge amplifier is presented. By means of a double feedback loop, the input field-effect transistor can operate with its gate junction sligtly forward biased, collecting the detector current and discharging the feedback capacitor. The feedback resistor is so avoided and no resetting device or circuit is required for the preamplifier operation. The noise is limited by the input transistor, an equivalent noise charge of 19.5 r.m.s. electrons has been measured at room temperature by employing a commercial JFET.


2016 ◽  
Vol 62 (3) ◽  
pp. 395-400
Author(s):  
Paweł Grochulski ◽  
Mirosław Cygler ◽  
Brian Yates

After a successful 10 years of operation, the Canadian Macromolecular Crystallography Facility 08ID-1 beamline will undergo an upgrade to establish micro-beam capability. This paper is mostly focussed on optics and computer simulations for ray tracing of the beamline. After completion, the focussed beam at the sample will have a much smaller size of 50 × 5 μm2 (H x V), allowing measurement of X-ray diffraction patterns from much smaller crystals than possible presently. The beamline will be equipped with a fast sample changer and an ultra-low noise photon counting detector, allowing shutter-less operation of the beamline. Additionally, it will be possible to perform in-situ room-temperature experiments.


Sign in / Sign up

Export Citation Format

Share Document