Statistical analysis of frequency response of island power system under increasing wind penetration

Author(s):  
I M Dudurych
Electricity ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 143-157
Author(s):  
Jovi Atkinson ◽  
Ibrahim M. Albayati

The operation and the development of power system networks introduce new types of stability problems. The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting from a sudden increase/decrease in the demand and/or generation. This paper investigates the impact of a loss of generation on the transient behaviour of the power grid frequency. A simplified power system model is proposed to examine the impact of change of the main generation system parameters (system inertia, governor droop setting, load damping constant, and the high-pressure steam turbine power fraction), on the primary frequency response in responding to the disturbance of a 1.32 GW generation loss on the UK power grid. Various rates of primary frequency responses are simulated via adjusting system parameters of the synchronous generators to enable the controlled generators providing a fast-reliable primary frequency response within 10 s after a loss of generation. It is concluded that a generation system inertia and a governor droop setting are the most dominant parameters that effect the system frequency response after a loss of generation. Therefore, for different levels of generation loss, the recovery rate will be dependent on the changes of the governor droop setting values. The proposed model offers a fundamental basis for a further investigation to be carried on how a power system will react during a secondary frequency response.


Energies ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 6483
Author(s):  
Vincenzo Trovato ◽  
Antonio De Paola ◽  
Goran Strbac

Thermostatically controlled loads (TCLs) can effectively support network operation through their intrinsic flexibility and play a pivotal role in delivering cost effective decarbonization. This paper proposes a scalable distributed solution for the operation of large populations of TCLs providing frequency response and performing energy arbitrage. Each TCL is described as a price-responsive rational agent that participates in an integrated energy/frequency response market and schedules its operation in order to minimize its energy costs and maximize the revenues from frequency response provision. A mean field game formulation is used to implement a compact description of the interactions between typical power system characteristics and TCLs flexibility properties. In order to accommodate the heterogeneity of the thermostatic loads into the mean field equations, the whole population of TCLs is clustered into smaller subsets of devices with similar properties, using k-means clustering techniques. This framework is applied to a multi-area power system to study the impact of network congestions and of spatial variation of flexible resources in grids with large penetration of renewable generation sources. Numerical simulations on relevant case studies allow to explicitly quantify the effect of these factors on the value of TCLs flexibility and on the overall efficiency of the power system.


Sign in / Sign up

Export Citation Format

Share Document