Measurement and Correction of Conducted Electrical Noise in Distributed Power Supplies (1kW) with Power Factor Corrector

Author(s):  
F.P. Ridao ◽  
J.M. Carrasco ◽  
L.G. Franquelo
Author(s):  
Xin Shen ◽  
Hongchun Shu ◽  
Min Cao ◽  
Nan Pan ◽  
Junbin Qian

In distribution networks with distributed power supplies, distributed power supplies can also be used as backup power sources to support the grid. If a distribution network contains multiple distributed power sources, the distribution network becomes a complex power grid with multiple power supplies. When a short-circuit fault occurs at a certain point on the power distribution network, the size, direction and duration of the short-circuit current are no longer single due to the existence of distributed power, and will vary with the location and capacity of the distributed power supply system. The change, in turn, affects the current in the grid, resulting in the generation and propagation of additional current. This power grid of power electronics will cause problems such as excessive standard mis-operation, abnormal heating of the converter and component burnout, and communication system failure. It is of great and practical significance to study the influence of distributed power in distributed power distribution networks.


Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5523
Author(s):  
Rodrigo De A. Teixeira ◽  
Werbet L. A. Silva ◽  
Guilherme A. P. De C. A. Pessoa ◽  
Joao T. Carvalho Neto ◽  
Elmer R. L. Villarreal ◽  
...  

This paper analyzes a Digital Signal Processor (DSP) based One Cycle Control (OCC) strategy for a Power Factor Corrector (PFC) rectifier with Common-mode Voltage (CMV) immunity. It is proposed a strategy that utilizes an emulated-resistance-controller in closed-loop configuration to set the dc-link voltage to achieve unity power factor (UPF). It is shown that if the PFC can achieve UPF condition and if the phase voltage is only affected by CMV, then phase current is free from CMV, as well as a lead-lag compensator (LLC) to average phase current.


2021 ◽  
Vol 2 (2) ◽  
pp. 29-35
Author(s):  
Dmitry A. Sorokin ◽  
◽  
Sergey I. Volskiy ◽  
Jaroslav Dragoun ◽  
◽  
...  

The paper suggests a control system of a three-phase power factor corrector. The study of the control system operation is carried out and the expressions for calculating the permissible values of error amplifier factors are obtained. The influence of the error amplifier parameters on phase current quality is investigated. The dependence of total harmonic distortion input current on a combination of error amplifier parameters is obtained at a given value of power factor. The conditions under which the total harmonic distortion input current has the minimum value are found out. This article is of interest to power electronics engineers, who are aimed at developing a three-phase power factor corrector.