Automatic Reclosing High-Speed Circuit Breaker Feeder Equipment for D-C. Railway Service

Author(s):  
A. E. Anderson
2021 ◽  
Vol 80 (5) ◽  
pp. 269-275
Author(s):  
L. A. German ◽  
E. A. Donskoy ◽  
S. A. Kapustin

Operation of sectioning posts of the AC catenary at the disconnectors on the Gorkovskaya railway for a period of more than 60 years has shown its reliable operation, and the maintenance was reduced to a minimum. However, due to the growth of heavy haul and high-speed traffic on a number of sections, their reconstruction was required. In accordance with the current regulatory documents, such a reconstruction provides for the transfer of the operation of sectioning posts from disconnectors to circuit breakers. In connection with the reliable operation of the sectioning posts on disconnectors and the simplicity of their maintenance, it is proposed to expand the options for the reconstruction of the sectioning posts on the disconnectors and to introduce three reconstruction options into the regulatory documents. The first option provides for the reconstruction of the sectioning post with disconnectors by transferring it to the classic scheme with four switches, as indicated in the current regulatory documents. The second option provides for leaving the sectioning post at the disconnectors, but adding a fast-acting automatic reclosing device in the inter-substation zone in case of passing short circuits. The third option provides for the reconstruction of the sectioning post on disconnectors with the introduction of a vacuum circuit breaker into the bus of the post and a device for high-speed automatic reclosing and opening of the disconnector, in the zone of which a short circuit has occurred. The schemes of automatic devices for determining a stable (passing) short circuit in a traction network and a device for determining the location of damage are considered. The operation of the sectioning posts, reconstructed according to the indicated options, has been tested practically at the existing sections of the power supply of the traction network of the Gorkovskaya railway. All of them have shown high reliability.


2014 ◽  
Vol 687-691 ◽  
pp. 934-937
Author(s):  
Shu Tao Zhao ◽  
Yu Tao Xu ◽  
Zhi Wan Cheng ◽  
Jian Feng Ren ◽  
Dan Jiang

Aim at the disadvantages of traditional circuit breaker mechanical characteristic parameters test. Get the motion pictures of insulation connecting rod through high-speed camera, using the finite difference method to quickly screen out the motion pictures, and selecting punctuation area as a template for learning, using non-uniform sampling have a template matching, obtain the center coordinates of matching results, time interval is known every frame. Through coordinate changes over time we can obtain mechanical parameters of the circuit breaker accurately, fast, conveniently. Lab VIEW programs achieve the above process automatically.


2017 ◽  
Vol 4 (3) ◽  
pp. 234-240 ◽  
Author(s):  
Y. Guo ◽  
H. Zhang ◽  
Y. Yao ◽  
Q. Zhang ◽  
J. D. Yan

A high voltage gas blast circuit breaker relies on the high speed gas flow in a nozzle to remove the energy due to Ohmic heating at high current and to provide strong arc cooling during the current zero period to interrupt a fault current. The physical mechanisms that are responsible for the hugely different arc cooling capabilities of two gases (SF<sub>6</sub> and air) are studied in the present work and important gas material properties controlling the cooling strength identified.


2015 ◽  
Vol 86 (2) ◽  
pp. 024704 ◽  
Author(s):  
Yifei Wu ◽  
Mingzhe Rong ◽  
Yi Wu ◽  
Fei Yang ◽  
Mei Li ◽  
...  

2019 ◽  
Vol 6 (3) ◽  
pp. 235-238
Author(s):  
I. Murashov ◽  
V. Frolov ◽  
A. Kvashnin ◽  
J. Valenta ◽  
D. Simek ◽  
...  

The article is devoted to the study of the high-current AC circuit breaker. The results of the study are presented for various configurations of the arc divider. The study includes methods of spectral diagnostics and high-speed camera shooting synchronized with the electrical characteristics of the circuit breaker (current, voltage) in time. The obtained results allow to determine the composition of the plasma and dynamics of changes in the composition of the discharge in time. Calculation of the plasma composition and properties is made according to the obtained data, which makes it possible to take into account the products of circuit breaker materials ablation in numerical simulation. Non-stationary two-dimensional mathematical model with a moving mesh is developed. The obtained results allow to correct and verify the developed mathematical model of the circuit breaker operation. The evaluation of the arc divider influence is presented in the article.