Efficient HVRT Scheme of DFIG Using a SSFCL-Chopper Considering Grid Voltage Recovery

Author(s):  
Zhi-Ce Zou ◽  
Jun Yao
2012 ◽  
Vol 608-609 ◽  
pp. 687-691
Author(s):  
Ze Xin Zhang ◽  
Guang Qing Bao

According to the provisions of low voltage ride through capability of wind turbines in the “large-scale design and technical specifications for wind farm to grid” of china, proposed a method to simulate this low voltage ride through grid voltage by computer simulation software. The simulation method is mainly used to simulate whether the wind turbines grid can meet the low voltage ride through requirements. In order to obtain the required grid voltage, the fault simulation circuit is divided into voltage dip part and voltage recovery part, which were used to simulated 20% & 90% voltage dip and the 20% grid voltage gradually recovered to 90% grid voltage. Three-phase fault modules for the voltage dip part, Three-phase programmable voltage source module for the voltage recovery part. The simulation results show that simulation system we build can simulate the required grid voltage.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2262 ◽  
Author(s):  
Hua Han ◽  
Chao Luo ◽  
Xiaochao Hou ◽  
Mei Su ◽  
Wenbin Yuan ◽  
...  

For an AC-stacked photovoltaic (PV) inverter system with N cascaded inverters, existing control methods require at least N communication links to acquire the grid synchronization signal. In this paper, a novel decentralized control is proposed. For N inverters, only one inverter nearest the point of common coupling (PCC) needs a communication link to acquire the grid voltage phase and all other N − 1 inverters use only local measured information to achieved fully decentralized local control. Specifically, one inverter with a communication link utilizes the grid voltage phase and adopts current control mode to achieve a required power factor (PF). All other inverters need only local information without communication links and adopt voltage control mode to achieve maximum power point tracking (MPPT) and self-synchronization with grid voltage. Compared with existing methods, the communication link and complexity is greatly reduced, thus improved reliability and reduced communication costs are achieved. The effectiveness of the proposed control is verified by simulation tests.


Author(s):  
Sharmin Rahman ◽  
Sajeeb Saha ◽  
Shama Naz Islam ◽  
M Arif ◽  
Mehdi Mosadeghy ◽  
...  

Author(s):  
Jun Jiang ◽  
Chengsheng Wang ◽  
Xiang Zhao ◽  
Wei Duan ◽  
Zhiming Lan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document