A new video differential phase-and-gain equalizer

Author(s):  
J. H. Clark
Keyword(s):  
Author(s):  
E.M. Waddell ◽  
J.N. Chapman ◽  
R.P. Ferrier

Dekkers and de Lang (1977) have discussed a practical method of realising differential phase contrast in a STEM. The method involves taking the difference signal from two semi-circular detectors placed symmetrically about the optic axis and subtending the same angle (2α) at the specimen as that of the cone of illumination. Such a system, or an obvious generalisation of it, namely a quadrant detector, has the characteristic of responding to the gradient of the phase of the specimen transmittance. In this paper we shall compare the performance of this type of system with that of a first moment detector (Waddell et al.1977).For a first moment detector the response function R(k) is of the form R(k) = ck where c is a constant, k is a position vector in the detector plane and the vector nature of R(k)indicates that two signals are produced. This type of system would produce an image signal given bywhere the specimen transmittance is given by a (r) exp (iϕ (r), r is a position vector in object space, ro the position of the probe, ⊛ represents a convolution integral and it has been assumed that we have a coherent probe, with a complex disturbance of the form b(r-ro) exp (iζ (r-ro)). Thus the image signal for a pure phase object imaged in a STEM using a first moment detector is b2 ⊛ ▽ø. Note that this puts no restrictions on the magnitude of the variation of the phase function, but does assume an infinite detector.


Author(s):  
M. Unser ◽  
B.L. Trus ◽  
A.C. Steven

Since the resolution-limiting factor in electron microscopy of biological macromolecules is not instrumental, but is rather the preservation of structure, operational definitions of resolution have to be based on the mutual consistency of a set of like images. The traditional measure of resolution for crystalline specimens in terms of the extent of periodic reflections in their diffraction patterns is such a criterion. With the advent of correlation averaging techniques for lattice rectification and the analysis of non-crystalline specimens, a more general - and desirably, closely compatible - resolution criterion is needed. Two measures of resolution for correlation-averaged images have been described, namely the differential phase residual (DPR) and the Fourier ring correlation (FRC). However, the values that they give for resolution often differ substantially. Furthermore, neither method relates in a straightforward way to the long-standing resolution criterion for crystalline specimens.


Author(s):  
F. Paonessa ◽  
G. Virone ◽  
S. Matteoli ◽  
P. Bolli ◽  
G. Pupillo ◽  
...  
Keyword(s):  

2019 ◽  
Vol 20 (5) ◽  
pp. 999-1014 ◽  
Author(s):  
Stephen B. Cocks ◽  
Lin Tang ◽  
Pengfei Zhang ◽  
Alexander Ryzhkov ◽  
Brian Kaney ◽  
...  

Abstract The quantitative precipitation estimate (QPE) algorithm developed and described in Part I was validated using data collected from 33 Weather Surveillance Radar 1988-Doppler (WSR-88D) radars on 37 calendar days east of the Rocky Mountains. A key physical parameter to the algorithm is the parameter alpha α, defined as the ratio of specific attenuation A to specific differential phase KDP. Examination of a significant sample of tropical and continental precipitation events indicated that α was sensitive to changes in drop size distribution and exhibited lower (higher) values when there were lower (higher) concentrations of larger (smaller) rain drops. As part of the performance assessment, the prototype algorithm generated QPEs utilizing a real-time estimated and a fixed α were created and evaluated. The results clearly indicated ~26% lower errors and a 26% better bias ratio with the QPE utilizing a real-time estimated α as opposed to using a fixed value as was done in previous studies. Comparisons between the QPE utilizing a real-time estimated α and the operational dual-polarization (dual-pol) QPE used on the WSR-88D radar network showed the former exhibited ~22% lower errors, 7% less bias, and 5% higher correlation coefficient when compared to quality controlled gauge totals. The new QPE also provided much better estimates for moderate to heavy precipitation events and performed better in regions of partial beam blockage than the operational dual-pol QPE.


2021 ◽  
Vol 118 (12) ◽  
pp. 124103
Author(s):  
Timothy D. Weber ◽  
Nikunj Khetan ◽  
Ruohui Yang ◽  
Jerome Mertz

Crystals ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 63
Author(s):  
Henning Tesmer ◽  
Rani Razzouk ◽  
Ersin Polat ◽  
Dongwei Wang ◽  
Rolf Jakoby ◽  
...  

In this paper we investigate the temperature dependent behavior of a liquid crystal (LC) loaded tunable dielectric image guide (DIG) phase shifter at millimeter-wave frequencies from 80 GHz to 110 GHz for future high data rate communications. The adhesive, necessary for precise fabrication, is analyzed before temperature dependent behavior of the component is shown, using the nematic LC-mixture GT7-29001. The temperature characterization is conducted by changing the temperature of the LC DIG’s ground plane between −10∘C and 80 ∘C. The orientation of the LC molecules, and therefore the effective macroscopic relative permittivity of the DIG, is changed by inserting the temperature setup in a fixture with rotatable magnets. Temperature independent matching can be observed, while the insertion loss gradually increases with temperature for both highest and lowest permittivity of the LC. At 80 ∘C the insertion loss is up to 1.3dB higher and at −10∘C it is 0.6dB lower than the insertion loss present at 20 ∘C. In addition, the achievable differential phase is reduced with increasing temperature. The impact of molecule alignment to this reduction is shown for the phase shifter and an estimated 85% of the anisotropy is still usable with an LC DIG phase shifter when increasing the temperature from 20 ∘C to 80 ∘C. Higher reduction of differential phase is present at higher frequencies as the electrical length of the phase shifter increases. A maximum difference in differential phase of 72∘ is present at 110 GHz, when increasing the temperature from 20 ∘C to 80 ∘C. Nevertheless, a well predictable, quasi-linear behavior can be observed at the covered temperature range, highlighting the potential of LC-based dielectric components at millimeter wave frequencies.


Sign in / Sign up

Export Citation Format

Share Document