Rotor Loss and Thermal Analysis of Synchronous Condenser Under Single-Phase Short-Circuit Fault in the Transmission Line

Author(s):  
Guorui Xu ◽  
Zhenzhen Wang ◽  
Jingdi Zhou ◽  
Zhiqiang Li ◽  
Yang Zhan ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 934
Author(s):  
Yanwen Wang ◽  
Le Wang ◽  
Sven G. Bilén ◽  
Yan Gao

Due to the working condition of low-voltage cabling from the mining flameproof movable substation to the loads of the mining face being poor, it is easy to cause various external mechanical damages to the cable sheaths. Furthermore, a single-phase earth leakage fault or short-circuit fault can occur when the low-voltage cable sheaths are damaged, and electric sparks caused by these faults can lead to a gas explosion. As the gas detonation time caused by the above faults is usually more than 5 ms, the high-speed interruption solid-state switch which controls the cables must cut off the current within 3 ms. This requires the action time of the solid-state switch to be less than 1 ms, and at the same time, the sampling and calculation time of the relay protection must be less than 2 ms. Based on these problems, this paper proposes the use of a high-speed solid-state circuit breaker (SSCB) topology at the neutral point of transformer, and analyzes the conduction mechanism and shut-off mechanism of the current of the SSCB. It presents an ultra-high-speed algorithm based on pattern recognition of single-phase earth leakage fault protection, and an ultra-high-speed algorithm of short-circuit fault which is based on the rate-of-change of the current. Finally, through computer simulation experiments and semi-physical simulation experiments, the feasibility of the above three technologies is verified to ensure that when a single-phase earth leakage fault or short-circuit fault occurs in the low-voltage cable, the solid-state switch which is installed in the mining flameproof movable substation will cut off the current within 3 ms.


2014 ◽  
Vol 521 ◽  
pp. 288-291
Author(s):  
Yu Sheng Quan ◽  
Xin Zhao ◽  
Hua Gui Chen ◽  
En Ze Zhou

Based on the method of symmetrical components of D, 11 and Y, o distribution transformer coupling two different effects of different magnetic circuit coupled to the three-phase system with a system-generated analysis and comparison. Analysis of the difference between the two groups of different connections on the transformer structure. Described in the single-phase short circuit fault clearing, 3n harmonic current suppression and affordability aspects of single-phase unbalanced load, D, ll coupling transformers are significantly better than Y,0 coupling transformer. This has necessarily important for the study of energy loss reduction.


2021 ◽  
Author(s):  
Md. Sihab Uddin ◽  
Erphan Bhuiyan ◽  
Subrata Sarker ◽  
Sajal Das ◽  
Niloy Sarker ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document