Cost-efficient in-situ end-of-life prognostics of power dies and LEDs by junction temperature measurement

Author(s):  
Sergey Sheva ◽  
Raul Mrossko ◽  
Jens Heilmann ◽  
Bernhard Wunderle ◽  
Gusztav Hantos ◽  
...  
2021 ◽  
Author(s):  
Adrian Ringenbach ◽  
Peter Bebi ◽  
Perry Bartelt ◽  
Andrin Caviezel

<p>Forests with a high density and basal area of living trees are known for their function as natural and cost-efficient protection against rockfall. The role of deadwood, however, is less understood. We address this knowledge gap in this contribution as we present the results of repeated real-scale experiments in a) a montane beech-spruce forest with and without deadwood and b) in a subalpine scrub mountain pine-spruce forest with deadwood. We used artificial rocks with either an equant or platy shape, masses between 45 kg and 800 kg (≈ 0.3 m3), and equipped with in-situ sensors to gain insights into rotational velocities and impact-accelerations. Clusters of deadwood and erected root plates reduced the mean runout distance at both study sites. For site a), we found that more rocks were stopped behind lying than living trees and that the stopping effect of deadwood was greater for equant compared to platy rock shapes. Site b) revealed a braking effect of scrub mountain pines for relatively small (45 kg), but also a visible reduction in rotational velocities for the 800 kg rocks sensor stream. We conclude that deadwood must be taken into account in rockfall modeling and the management of rockfall protection forests.</p>


2022 ◽  
Vol 43 (3) ◽  
Author(s):  
Jonathan Pearce ◽  
Declan Tucker ◽  
Carmen García Izquierdo ◽  
Raul Caballero ◽  
Trevor Ford ◽  
...  

AbstractMineral insulated, metal sheathed (MI) Type K and Type N thermocouples are widely used in industry for process monitoring and control. One factor that limits their accuracy is the dramatic decrease in the insulation resistance at temperatures above about 600 °C which results in temperature measurement errors due to electrical shunting. In this work the insulation resistance of a cohort of representative MI thermocouples was characterised at temperatures up to 1160 °C, with simultaneous measurements of the error in indicated temperature by in situ comparison with a reference Type R thermocouple. Intriguingly, there appears to be a systematic relationship between the insulation resistance and the error in the indicated temperature. At a given temperature, as the insulation resistance decreases, there is a corresponding increasingly negative error in the temperature measurement. Although the measurements have a relatively large uncertainty (up to about 1 °C in temperature error and up to about 10 % in insulation resistance measurement), the trend is apparent at all temperatures above 600 °C, which suggests that it is real. Furthermore, the correlation disappears at temperatures below about 600 °C, which is consistent with the well-established diminution of insulation resistance breakdown effects below that temperature. This raises the intriguing possibility of using the as-new MI thermocouple calibration as an indicator of insulation resistance breakdown: large deviations of the electromotive force (emf) in the negative direction could indicate a correspondingly low insulation resistance.


CLEO: 2013 ◽  
2013 ◽  
Author(s):  
Jonathan Mueller ◽  
Joachim Fischer ◽  
Yatin Jadavji Mange ◽  
Thomas Nann ◽  
Martin Wegener