Experimental Study of the Transfer Function of Replicas of Pinnae of Individuals Manufactured with Alginate

2020 ◽  
Vol 18 (01) ◽  
pp. 16-23
Author(s):  
Sebastian Fingerhuth ◽  
Jose Luis Bravo ◽  
Marcelo Bustamante ◽  
Francisco Pizarro
2015 ◽  
Vol 2015.90 (0) ◽  
pp. 37
Author(s):  
Masayuki ICHIMONJI ◽  
Yuki MIMURA ◽  
Kazunori IKEDA ◽  
Toshio HIRANO

2012 ◽  
Vol 433-440 ◽  
pp. 6077-6083
Author(s):  
Xu Yan ◽  
Tie Ying Li

In order to have a better understanding of the vibration characteristics, micro tremor measurements are carried out on Yingxian Wooden pagoda. Horizontal vibration modes of the tower and the torsional vibration modes on each floor are attained by analysis of the test results. Based on transfer function method, elastic displacements of the tower under the different seismic waves are derived. Trough theoretical analysis, the significative conclusions are received as a basis for researching and protecting the ancient building.


Author(s):  
H.A. Cohen ◽  
W. Chiu

The goal of imaging the finest detail possible in biological specimens leads to contradictory requirements for the choice of an electron dose. The dose should be as low as possible to minimize object damage, yet as high as possible to optimize image statistics. For specimens that are protected by low temperatures or for which the low resolution associated with negative stain is acceptable, the first condition may be partially relaxed, allowing the use of (for example) 6 to 10 e/Å2. However, this medium dose is marginal for obtaining the contrast transfer function (CTF) of the microscope, which is necessary to allow phase corrections to the image. We have explored two parameters that affect the CTF under medium dose conditions.Figure 1 displays the CTF for carbon (C, row 1) and triafol plus carbon (T+C, row 2). For any column, the images to which the CTF correspond were from a carbon covered hole (C) and the adjacent triafol plus carbon support film (T+C), both recorded on the same micrograph; therefore the imaging parameters of defocus, illumination angle, and electron statistics were identical.


Author(s):  
N. Bonnet ◽  
M. Troyon ◽  
P. Gallion

Two main problems in high resolution electron microscopy are first, the existence of gaps in the transfer function, and then the difficulty to find complex amplitude of the diffracted wawe from registered intensity. The solution of this second problem is in most cases only intended by the realization of several micrographs in different conditions (defocusing distance, illuminating angle, complementary objective apertures…) which can lead to severe problems of contamination or radiation damage for certain specimens.Fraunhofer holography can in principle solve both problems stated above (1,2). The microscope objective is strongly defocused (far-field region) so that the two diffracted beams do not interfere. The ideal transfer function after reconstruction is then unity and the twin image do not overlap on the reconstructed one.We show some applications of the method and results of preliminary tests.Possible application to the study of cavitiesSmall voids (or gas-filled bubbles) created by irradiation in crystalline materials can be observed near the Scherzer focus, but it is then difficult to extract other informations than the approximated size.


Sign in / Sign up

Export Citation Format

Share Document