Analysis and Design of Feedforward Linearity-Improved Mixer Using Inductive Source Degeneration

2014 ◽  
Vol 62 (2) ◽  
pp. 323-331 ◽  
Author(s):  
Myoung-Gyun Kim ◽  
Tae-Yeoul Yun
Electronics ◽  
2020 ◽  
Vol 9 (4) ◽  
pp. 596
Author(s):  
Raymond Gyaang ◽  
Dong-Ho Lee ◽  
Jusung Kim

This paper presents the analysis and design of the harmonic rejection (HR) low-noise amplifier (LNA) with the fully passive source degeneration notch filter. The proposed HR LNA provides the rejection for the strong harmonics ( 3 r d ) of the local oscillator (LO) frequencies, where the HR mixer does not provide sufficient HR performance. The proposed 3 r d harmonic notch filter modulates the source degeneration factor and the impedance matching performance thereafter. This effect further helps the blocking of the harmonic signal. The proposed LNA provides 11 dB gain at the fundamental frequency (2.1 GHz) while rejecting the 3rd harmonic component by 37 dBc. Compared to the conventional LNA, the 3rd harmonic notch performance is improved by 23 dB. Additionally, the LNA achieves a minimum noise figure of 3.1 dB, third order input intercept point ( I I P 3 ) of 0.5 dBm, input reflection (S 11 ) below −10 dB from 1.8 GHz–2.3 GHz operational frequency range, and consumed 19 mW of power from a 1.2 V supply.


1996 ◽  
Vol 35 (01) ◽  
pp. 52-58 ◽  
Author(s):  
A. Mavromatis ◽  
N. Maglaveras ◽  
A. Tsikotis ◽  
G. Pangalos ◽  
V. Ambrosiadou ◽  
...  

AbstractAn object-oriented medical database management system is presented for a typical cardiologic center, facilitating epidemiological trials. Object-oriented analysis and design were used for the system design, offering advantages for the integrity and extendibility of medical information systems. The system was developed using object-oriented design and programming methodology, the C++ language and the Borland Paradox Relational Data Base Management System on an MS-Windows NT environment. Particular attention was paid to system compatibility, portability, the ease of use, and the suitable design of the patient record so as to support the decisions of medical personnel in cardiovascular centers. The system was designed to accept complex, heterogeneous, distributed data in various formats and from different kinds of examinations such as Holter, Doppler and electrocardiography.


KURVATEK ◽  
2018 ◽  
Vol 3 (1) ◽  
pp. 21-34
Author(s):  
Untung Wahyudi ◽  
Excelsior T P ◽  
Luthfi Wahyudi

PT. Putera Bara Mitra used open mining system for mining operation, Yet the completion of study on the end wall slope stability that  undertaken by geotechnical PT. Putera Bara Mitra in Northwest Pit and the occured a failure in the low wall on the 1st June 2012 led to the need for analysis and design the overall slope at the mine site. To analyze and design the overall slope, used value of the recommended minimum safety. The value was based on company for single slope SF ≥ 1.2 and SF ≥ 1.3 for overall slope. The calculation used Bichop method with the help of software slide v 5.0. Geometry improvements was done at the low slopes that originally single wall with a 30 m bench height and a slope 70° with SF = 0.781, into 4 levels with SF = 1.305. The analysis explained the factors that affect the stability of the low wall included the mining slope geometry, unfavorable drainase system, material stockpiles and seismicity factors. It was necessary to do prevention efforts to maintain the stability of the slope included the redesign to slope geometry, handling surface and subsurface water in a way to control slopes draining groundwater, vegetation stabilization using and monitoring slope using Total Station with Prism and Crackmeter to determine the movement of cracks visible on the surface. 


2007 ◽  
Author(s):  
N. E. Shanmugam ◽  
C. M. Wang
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document