A Modular Scintillation Camera for Use in Nuclear Medicine

1984 ◽  
Vol 31 (1) ◽  
pp. 578-580 ◽  
Author(s):  
T. D. Milster ◽  
L. A. Selberg ◽  
H. H. Barrett ◽  
R. L. Easton ◽  
G. R. Rossi ◽  
...  
1975 ◽  
Vol 14 (04) ◽  
pp. 330-338
Author(s):  
L. G. Colombetti ◽  
J. S. Arnold ◽  
W. E. Barnes

SummaryTc-99m pyridoxylidene glutamate has proven to be an excellent biliary scanning agent, far superior in many respect to the commonly used 1-131 rose bengal. The preparation of the compound as previously reported by Baker et al is too time consuming and requires the use of an autoclave which is not available in most nuclear medicine departments. In our facility, we have been preparing similar compounds using several aldehydes and monosodium glutamate to make labeled complexes having the same pharmacological characteristics. The mixture of monosodium glutamate, aldehyde, and Tc-99m pertechnetate is made slightly alkaline, purged with helium, and placed in a sealed vial. The vial, which is protected by a wire basket, is then heated in a laboratory oven at 130° C for a period of 15 to 20 minutes. During this time, the technetium is reduced to a lower valence state and bound to the complex formed. Chromatographic data show that these compounds are chemically similar to that previously reported. The compounds prepared concentrate in the gall bladder of the rabbit in less than 10 minutes. Kinetic studies have been performed on dogs with a scintillation camera and small digital computer to measure rates of blood clearance, liver and gall bladder uptake, and excretion into the intestine. The aldehyde — glutamate complex promises to be a useful scanning agent for the diagnosis of biliary and hepatocellular diseases.


Radiology ◽  
1971 ◽  
Vol 101 (3) ◽  
pp. 643-649 ◽  
Author(s):  
Max C. Downham ◽  
Ronald G. Evens

1993 ◽  
Vol 11 (1) ◽  
pp. 22-28 ◽  
Author(s):  
J-C Darras ◽  
P Albarède ◽  
P de Vernejoul

The aim of this study is to investigate the pathways of acupuncture meridians in the human body through the injection of radioactive tracers at acupuncture points. Technetium 99m (99mTc) as sodium pertechnetate, the most common radioactive tracer in nuclear medicine, has been used. The migration patterns were recorded with a scintillation camera associated with computer imaging capabilities. Our findings show that the preferential pathways taken by the radiotracer coincide with acupuncture meridians as described in Chinese traditional medicine. More, it has been established that these pathways are distinguishable from either lymphatic or vascular routes.


2002 ◽  
Vol 120 (2) ◽  
pp. 45-48 ◽  
Author(s):  
Celso Darío Ramos ◽  
Denise Engelbrecht Zantut Wittmann ◽  
Elba Cristina Sá de Camargo Etchebehere ◽  
Marcos Antonio Tambascia ◽  
Cleide Aparecida Moreira Silva ◽  
...  

CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc- pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.


1990 ◽  
Vol 137 (3) ◽  
pp. 163 ◽  
Author(s):  
V.A. Oliveira ◽  
J.M. Nightingale

2020 ◽  
Vol 59 (04) ◽  
pp. 294-299 ◽  
Author(s):  
Lutz S. Freudenberg ◽  
Ulf Dittmer ◽  
Ken Herrmann

Abstract Introduction Preparations of health systems to accommodate large number of severely ill COVID-19 patients in March/April 2020 has a significant impact on nuclear medicine departments. Materials and Methods A web-based questionnaire was designed to differentiate the impact of the pandemic on inpatient and outpatient nuclear medicine operations and on public versus private health systems, respectively. Questions were addressing the following issues: impact on nuclear medicine diagnostics and therapy, use of recommendations, personal protective equipment, and organizational adaptations. The survey was available for 6 days and closed on April 20, 2020. Results 113 complete responses were recorded. Nearly all participants (97 %) report a decline of nuclear medicine diagnostic procedures. The mean reduction in the last three weeks for PET/CT, scintigraphies of bone, myocardium, lung thyroid, sentinel lymph-node are –14.4 %, –47.2 %, –47.5 %, –40.7 %, –58.4 %, and –25.2 % respectively. Furthermore, 76 % of the participants report a reduction in therapies especially for benign thyroid disease (-41.8 %) and radiosynoviorthesis (–53.8 %) while tumor therapies remained mainly stable. 48 % of the participants report a shortage of personal protective equipment. Conclusions Nuclear medicine services are notably reduced 3 weeks after the SARS-CoV-2 pandemic reached Germany, Austria and Switzerland on a large scale. We must be aware that the current crisis will also have a significant economic impact on the healthcare system. As the survey cannot adapt to daily dynamic changes in priorities, it serves as a first snapshot requiring follow-up studies and comparisons with other countries and regions.


1978 ◽  
Vol 17 (03) ◽  
pp. 110-125 ◽  
Author(s):  
O.P.D Noronha

A review is made of some of the factors affecting bioavailability of diagnostic 99mTc-radiopharmaceuticals currently used in the practice of nuclear medicine.


2007 ◽  
Vol 46 (02) ◽  
pp. 49-55 ◽  
Author(s):  
W. Burchert ◽  
F. M. Bengel ◽  
R. Zimmermann ◽  
J. vom Dahl ◽  
W. Schäfer ◽  
...  

SummaryThe working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: A questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (>75%) was performed with 99mTc-MIBI or tetrofosmin. 201Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: In Germany, MPS is predominantly performed with 99mTc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization.


Sign in / Sign up

Export Citation Format

Share Document