A Study on the Effects of Release Area on the Quality Factor of Contour-Mode Resonators by Laser Doppler Vibrometry

Author(s):  
Brian Gibson ◽  
Kamala Qalandar ◽  
Cristian Cassella ◽  
Gianluca Piazza ◽  
Kimberly L. Foster
Author(s):  
Cheng Tu ◽  
Joshua E.-Y. Lee ◽  
Astrid Frank ◽  
Christoph Schaffel ◽  
Uwe Stehr ◽  
...  

2017 ◽  
Vol 263 ◽  
pp. 188-197 ◽  
Author(s):  
C. Tu ◽  
A. Frank ◽  
S. Michael ◽  
J. Stegner ◽  
U. Stehr ◽  
...  

2021 ◽  
Vol 70 ◽  
pp. 1-10
Author(s):  
Sara Casaccia ◽  
Erik J. Sirevaag ◽  
Mark G. Frank ◽  
Joseph A. O'Sullivan ◽  
Lorenzo Scalise ◽  
...  

2015 ◽  
Vol 24 (4) ◽  
pp. 1038-1042 ◽  
Author(s):  
Celso Accoto ◽  
Antonio Qualtieri ◽  
Ferruccio Pisanello ◽  
Carlo Ricciardi ◽  
Candido Fabrizio Pirri ◽  
...  

Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 143
Author(s):  
Sitao Fei ◽  
Hao Ren

As a result of their IC compatibility, high acoustic velocity, and high thermal conductivity, aluminum nitride (AlN) resonators have been studied extensively over the past two decades, and widely implemented for radio frequency (RF) and sensing applications. However, the temperature coefficient of frequency (TCF) of AlN is −25 ppm/°C, which is high and limits its RF and sensing application. In contrast, the TCF of heavily doped silicon is significantly lower than the TCF of AlN. As a result, this study uses an AlN contour mode ring type resonator with heavily doped silicon as its bottom electrode in order to reduce the TCF of an AlN resonator. A simple microfabrication process based on Silicon-on-Insulator (SOI) is presented. A thickness ratio of 20:1 was chosen for the silicon bottom electrode to the AlN layer in order to make the TCF of the resonator mainly dependent upon heavily doped silicon. A cryogenic cooling test down to 77 K and heating test up to 400 K showed that the resonant frequency of the AlN resonator changed linearly with temperature change; the TCF was shown to be −9.1 ppm/°C. The temperature hysteresis characteristic of the resonator was also measured, and the AlN resonator showed excellent temperature stability. The quality factor versus temperature characteristic was also studied between 77 K and 400 K. It was found that lower temperature resulted in a higher quality factor, and the quality factor increased by 56.43%, from 1291.4 at 300 K to 2020.2 at 77 K.


2021 ◽  
Vol 48 (7) ◽  
pp. 0704003
Author(s):  
席崇宾 Xi Chongbin ◽  
黄荣 Huang Rong ◽  
周健 Zhou Jian ◽  
聂晓明 Nie Xiaoming

2021 ◽  
Author(s):  
Sejong Chun ◽  
Sibok Lee ◽  
Hyewon Yoon

Abstract Thermowells with helical strakes are becoming promising to prevent them from fatigue fracture by Kármán vortex street. Many studies suggest various kinds of measurement techniques, including strain rate measurement, acceleration measurement, and high-speed visualization to evaluate the role of Kármán vortex street to the flow-induced vibration. Nevertheless, use of laser Doppler vibrometry has not yet been reported in the literature. This study compared the tip deflection of a thermowell due to the flow-induced vibration by using the laser Doppler vibrometry and the strain rate measurement. The laser Doppler vibrometry could measure the tip deflection directly. On the other hand, the strain rate measurement had to convert the strain rate into the tip deflection through the Euler-Bernoulli beam theory. Measurement equivalence between the laser Doppler vibrometry and the strain rate measurement was discussed with the results of tip deflections of the thermowell.


2018 ◽  
Vol 184 ◽  
pp. 1030-1039 ◽  
Author(s):  
L. Maio ◽  
F. Ricci ◽  
V. Memmolo ◽  
E. Monaco ◽  
N.D. Boffa

Sign in / Sign up

Export Citation Format

Share Document