False negative for anti‐BP180 antibody by chemiluminescent enzyme immunoassay: Dissociation from enzyme‐linked immunosorbent assay and extended antigen‐antibody reaction time

Author(s):  
Taketoshi Futatsuya ◽  
Toshiki Fujii ◽  
Akiko Nishibu ◽  
Takashi Mochizuki ◽  
Yosuke Mai ◽  
...  
2000 ◽  
Vol 12 (2) ◽  
pp. 136-141 ◽  
Author(s):  
Ashok K. Singh

Serum samples from cats and pigs were analyzed by the solid-phase chemiluminescent enzyme immunoassay (SPCEI), enzyme-linked immunosorbent assay (ELISA), and indirect latex agglutination (ILA) methods. The SPCEI and ILA methods accurately analyzed Toxoplasma IgG (T-IgG) in both clinical and spiked samples from pigs and cats. The ELISA method accurately analyzed T-IgG in spiked samples from cats and pigs or clinical samples from pigs, but it did not accurately analyze T-IgG in clinical samples from cats. The antibody used in the ELISA kit did not cross-react with cat T-IgG. The SPCEI method that uses a stand-alone automated analyzer provided quantitative analysis, whereas the ELISA and ILA methods provided qualitative or, at best, semiquantitative analysis of T-IgG. The SPCEI and ELISA methods were rapid (60–90 minutes for 30 samples), whereas the ILA method required 13–15 hours for 30 samples. Although the three methods accurately distinguished positive from negative samples, the ILA method yielded many weakly positive results that were not confirmed by either the ELISA or SPCEI method. Thus, the indirect agglutination tests may give nonspecific responses at lower T-IgG concentrations.


1999 ◽  
Vol 37 (12) ◽  
pp. 4150-4152 ◽  
Author(s):  
A. van der Ende ◽  
R. W. M. van der Hulst ◽  
P. Roorda ◽  
G. N. J. Tytgat ◽  
J. Dankert

The sera of 142 Helicobacter pylori-positive and 32H. pylori-negative patients were assessed by a desktop test (QuickVue), an enzyme-linked immunosorbent assay (ELISA) (HM-CAP), and a solid-phase, two-step chemiluminescent enzyme immunoassay (Immulite). These tests yielded sensitivities of 97, 97, and 91% and specificities of 97, 94, and 100%, respectively. In conclusion, the desktop test and the ELISA are more sensitive than the chemiluminescent enzyme immunoassay (P < 0.05). The chemiluminescent enzyme immunoassay has the advantage that it is fully automated.


2003 ◽  
Vol 69 (6) ◽  
pp. 3492-3499 ◽  
Author(s):  
Yang Hong ◽  
Mark E. Berrang ◽  
Tongrui Liu ◽  
Charles L. Hofacre ◽  
Susan Sanchez ◽  
...  

ABSTRACT Contamination of retail poultry by Campylobacter spp. and Salmonella enterica is a significant source of human diarrheal disease. Isolation and identification of these microorganisms require a series of biochemical and serological tests. In this study, Campylobacter ceuE and Salmonella invA genes were used to design probes in PCR-enzyme-linked immunosorbent assay (ELISA), as an alternative to conventional bacteriological methodology, for the rapid detection of Campylobacter jejuni, Campylobacter coli, and S. enterica from poultry samples. With PCR-ELISA (40 cycles), the detection limits for Salmonella and Campylobacter were 2 � 102 and 4 � 101 CFU/ml, respectively. ELISA increased the sensitivity of the conventional PCR method by 100- to 1,000-fold. DNA was extracted from carcass rinses and tetrathionate enrichments and used in PCR-ELISA for the detection of Campylobacter and S. enterica, respectively. With PCR-ELISA, Salmonella was detected in 20 of 120 (17%) chicken carcass rinses examined, without the inclusion of an enrichment step. Significant correlation was observed between PCR-ELISA and cultural methods (kappa = 0.83; chi-square test, P < 0.001) with only one false negative (1.67%) and four false positives (6.67%) when PCR-ELISA was used to screen 60 tetrathionate enrichment cultures for Salmonella. With PCR-ELISA, we observed a positive correlation between the ELISA absorbance (optical density at 405 nm) and the campylobacter cell number in carcass rinse, as determined by standard culture methods. Overall, PCR-ELISA is a rapid and cost-effective approach for the detection and enumeration of Salmonella and Campylobacter bacteria on poultry.


1992 ◽  
Vol 38 (10) ◽  
pp. 1954-1958 ◽  
Author(s):  
S Ogiwara ◽  
K Kiuchi ◽  
T Nagatsu ◽  
R Teradaira ◽  
I Nagatsu ◽  
...  

Abstract An enzyme immunosorbent assay of neopterin and biopterin on a polystyrene microtiter plate has been developed. A conjugate of neopterin or biopterin to bovine serum albumin was used to raise a specific antiserum against neopterin or biopterin in rabbits. An incubation mixture of the antiserum and samples prepared from human serum underwent another antigen-antibody reaction with the hapten fixed on the microtiter plate. The amount of antibody bound to the fixed hapten, which is inverse to the amount of hapten in the sample, was determined by using anti-rabbit IgG-horseradish peroxidase conjugate in a usual manner by measuring absorbance at 490 nm after reaction with o-phenylenediamine and hydrogen peroxide. The minimal detectable amounts of neopterin and biopterin were approximately 0.1 pmol. The specificity of the assay was so high that the assay system for neopterin completely distinguished it from biopterin, as judged from the cross-reaction of 0.002%, and vice versa. The amounts of neopterin and biopterin in human serum determined by the present method agreed well with those determined by high-performance liquid chromatography. We used the present method to determine the concentrations of neopterin in serum from healthy control subjects and patients with cancers and systemic lupus erythematosus; the results were consistent with literature data.


1997 ◽  
Vol 13 (13) ◽  
pp. 1141-1146 ◽  
Author(s):  
GIANGUGLIELMO ZEHENDER ◽  
CHIARA DE MADDALENA ◽  
MONICA GIANOTTO ◽  
BARBARA CAVALLI ◽  
SARA SANTAMBROGIO ◽  
...  

2021 ◽  
Vol 5 (5) ◽  
pp. 447-453
Author(s):  
Rachmat Hidayat ◽  
Patricia Wulandari

ELISA (Enzyme-linked immunosorbent assay) is a technique used to assess the quantification of peptide, protein, antibody and hormone levels, based on the principle of antigen-antibody binding. In the ELISA technique, antigen immobilization will be carried out on a solid surface, then bound with antibodies to form an antigen-antibody bond complex, where the antigen-antibody complex is bound to the enzyme. The detection signal in the form of a color change will be formed due to the reaction between the enzyme and the substrate.


2005 ◽  
Vol 12 (11) ◽  
pp. 1322-1327 ◽  
Author(s):  
Jennifer M. Scotter ◽  
Stephen T. Chambers

ABSTRACT The performance of different in vitro diagnostic tests for the diagnosis of invasive aspergillosis (IA) was investigated in a transiently neutropenic rat model. Rats were immunosuppressed with cyclophosphamide and then inoculated intravenously with 1.5 × 104 CFU Aspergillus fumigatus spores. Animals were then either treated with caspofungin acetate, 1 mg/kg/day for 7 days, or not treated. PCR-enzyme-linked immunosorbent assay (ELISA), real-time PCR, and galactomannan (GM) detection were performed on postmortem blood samples, along with culture of liver, lung, and kidney homogenate. Caspofungin-treated animals showed a decrease in residual tissue burden of  A. fumigatus from organ homogenate compared to untreated animals (P < 0.002). PCR-ELISA returned positive results for 11/17 animals treated with antifungal agents and for 10/17 untreated animals. Galactomannan was positive in 8/17 caspofungin-treated animals and 4/17 untreated animals. Real-time PCR was positive in 2/17 treated and 3/17 untreated animals. This study demonstrates that PCR-ELISA is a more sensitive test than either GM detection (P = 0.052) or real-time PCR (P < 0.01) for diagnosis of IA but that any of the three tests may return false-negative results in cases of histologically proven disease. Galactomannan indices from animals treated with antifungal agents showed a trend (P = 0.1) towards higher levels than those of untreated animals, but no effect was observed with PCR-ELISA indices (P = 0.29). GM detection, as previously described, may be enhanced by the administration of caspofungin, but PCR-ELISA appears not to be affected in the same way. We conclude that PCR-ELISA is a more sensitive and reliable method for laboratory diagnosis of IA.


Sign in / Sign up

Export Citation Format

Share Document