Morphologic and cytogenetic variables affect the flow cytometric recovery of plasma cell myeloma cells in bone marrow aspirates

2015 ◽  
Vol 37 (6) ◽  
pp. 797-808 ◽  
Author(s):  
C. H. Cogbill ◽  
M. D. Spears ◽  
P. Vantuinen ◽  
A. M. Harrington ◽  
H. Olteanu ◽  
...  
Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 5036-5036
Author(s):  
Tove Isaacson ◽  
Andrzej Jakubowiak ◽  
Lloyd Stoolman ◽  
Usha Kota ◽  
William Finn ◽  
...  

Abstract Multiparameter flow cytometry is a useful tool for comprehensive immunophenotyping of plasma cell myeloma, and has been proposed as a sensitive method for the evaluation of minimal residual disease in patients following treatment. This study aimed to assess the value of flow cytometry in quantitation of residual disease, in comparison to routine morphologic examination of first-pull bone marrow aspirate smears, in myeloma patients post-therapy. Heparinized bone marrow aspirates were obtained from 27 treated patients with plasma cell myeloma. Cells were prepared for 5-color flow cytometric analysis within 24-hours of specimen draw. Surface membrane staining with anti-CD19, CD20, CD38, CD45, CD56, and CD138 was followed by ammonium chloride lysis of red cells. Fixed and permeabilized cells were analyzed for cytoplasmic light chains to confirm clonality. Data were acquired using an FC500 flow cytometer (Beckman-Coulter), analyzed with CXP software with plasma cells isolated based on bright CD38+ or CD138+ expression. A median of 97,639 cellular events (range 14,279 to 262,508) were collected per analysis. Flow cytometric enumeration of plasma cells was compared to 500-cell differential counts of Wright-Giemsa-stained first-pull aspirate smears from the same cases. The median plasma cell count as determined by flow cytometry was 0.5% (range 0–7.9%). The median plasma cell count estimated by morphologic review was 8.0% (range 0–84.4%). Flow cytometry underestimated the plasma cell content in all but one case. Clonal plasma cells expressed CD38 and CD138 in all cases; 87.5% (21/24) coexpressed CD56, 25% (6/24) coexpressed CD45, and 4.2% (1/24) coexpressed CD19. None was positive for CD20. Although detection of minimal residual disease after therapy for acute leukemia is routinely achieved by flow cytometric analysis, successful quantitation of minimal residual disease in treated myeloma patients using flow cytometry remains limited as it usually underestimates the plasma cell content of bone marrow samples compared to routine morphology of first-pull aspirates. We have observed that this holds true for both pre-treatment and post-treatment specimens. Causes for the discrepancy may include hemodilution of second-pull aspirates used for flow cytometry, fragility and loss of plasma cells during preparation for flow cytometry, and incomplete disaggregation of plasma cells from bone marrow spicules. With improved outcome of treatments, better and more reliable methods of detection of minimal residual disease are needed for optimal prognostic stratification. We are currently validating alternative methods, which may offer more sensitivity while at the same time allow more objectivity, for assessing the amount of minimal residual disease in myeloma patients.


2019 ◽  
Vol 5 (4) ◽  
pp. 20190025
Author(s):  
Margaret Mwania ◽  
Naushad Karim ◽  
Sarah Wambui ◽  
Shamshudin Mohammedali ◽  
Allan Njau

Plasma cell myeloma is a bone marrow disorder characterized by neoplastic proliferation of plasma cells within the bone marrow replacing normal cells. We present a case report of a 25-year-old female with bilateral lower and upper limb pains. She had been seen in various health facilities for the past 2 years with progressively worsening disability. Skeletal survey revealed multiple osteolytic lesions in the appendicular skeleton resembling vanishing bone syndrome. Ultrasound-guided biopsy was done with histological diagnosis of plasma cell myeloma. This case is unique because of the young age at presentation, HIV seropositive status and atypical appearance of the lesions.


2015 ◽  
Vol 5 (9) ◽  
pp. 739-746
Author(s):  
S Upadhyaya Baskota ◽  
AR Joshi ◽  
SK Singh

Background: Morphological examination of the marrow requires a combination of a properly prepared bone marrow aspirate smear, a trephine biopsy section and an imprint of core biopsy. Some conditions often result in a dry tap and are best studied by marrow biopsy.The major drawbacks of biopsy sections are their thickness, precludingfine morphologic detail.The objective of this study was to compare the diagnostic accuracy, cellularity and cytomorphology from bone marrow biopsy core imprint smears with bone marrow aspiration smears.Materials and Methods: Imprint smears were prepared from 138 cases subjected to bone marrow examination. The bone marrow aspiration, imprint smears andbone marrow biopsy sections were examined and were categorized into five different groups on cytomorphological basis: Non-malignant alterations and normal marrow, Myeloid neoplasms, Plasma cell myeloma, myelo-infiltrative disease and absence of residual disease and further delineated into specific entities wherever necessary.Results: Out of 138 cases, non-malignant alterations and normal marrow was the largest subgroup (N=87, 63%), followed by myeloid neoplasms (N=26, 18.5%), Plasma cell myeloma (N=13, 9.4%), myelo-infiltrative disease (N=9, 6.5%) and absence of residual disease (N=3, 2.2%). The diagnostic accuracy of imprint smears was highest (92%) followed by biopsy sections (89.9%) and aspiration smears (87%). Kappa analysis showed strong agreement (>0.8) and p-value was statistically significant (<0.001) while correlating the final diagnosis.Conclusion: Imprint smear technique is a simple, rapid, inexpensive and reliable procedure. The routine use of imprint smear in the bone marrow examination will serve as an invaluable adjunct to bone marrow aspiration and biopsy.Journal of Pathology of Nepal (2015) Vol. 5, 739-746


2019 ◽  
Vol 33 (2) ◽  
pp. 188-195
Author(s):  
Yansheng Hao ◽  
Daniel Khaykin ◽  
Levi Machado ◽  
Tayler van den Akker ◽  
Jane Houldsworth ◽  
...  

Blood ◽  
1994 ◽  
Vol 84 (7) ◽  
pp. 2269-2277 ◽  
Author(s):  
HM Lokhorst ◽  
T Lamme ◽  
M de Smet ◽  
S Klein ◽  
RA de Weger ◽  
...  

Abstract Long-term bone marrow cultures (LTBMC) from patients with multiple myeloma (MM) and normal donors were analyzed for immunophenotype and cytokine production. Both LTBMC adherent cells from myeloma and normal donor origin expressed CD10, CD13, the adhesion molecules CD44, CD54, vascular cell adhesion molecule 1, very late antigen 2 (VLA-2), and VLA- 5, and were positive for extracellular matrix components fibronectin, laminin, and collagen types 3 and 4. LTBMC from myeloma patients and normal donors spontaneously secreted interleukin-6 (IL-6). However, levels of IL-6 correlated with the stage of disease; highest levels of IL-6 were found in LTBMC from patients with active myeloma. To identify the origin of IL-6 production, LTBMC from MM patients and normal donors were cocultured with BM-derived myeloma cells and cells from myeloma cell lines. IL-6 was induced by plasma cell lines that adhered to LTBMC such as ARH-77 and RPMI-8226, but not by nonadhering cell lines U266 and FRAVEL. Myeloma cells strongly stimulated IL-6 secretion in cocultures with LTBMC adherent cells from normal donors and myeloma patients. When direct cellular contact between LTBMC and plasma cells was prevented by tissue-culture inserts, no IL-6 production was induced. This implies that intimate cell-cell contact is a prerequisite for IL-6 induction. Binding of purified myeloma cells to LTBMC adherent cells was partly inhibited by monoclonal antibodies against adhesion molecules VLA-4, CD44, and lymphocyte function-associated antigen 1 (LFA-1) present on the plasma cell. Antibodies against VLA-4, CD29, and LFA-1 also inhibited the induced IL-6 secretion in plasma cell-LTBMC cocultures. In situ hybridization studies performed before and after coculture with plasma cells indicated that LTBMC adherent cells produce the IL-6. These results suggest that the high levels of IL-6 found in LTBMC of MM patients with active disease are a reflection of their previous contact with tumor cells in vivo. These results provide a new perspective on tumor growth in MM and emphasize the importance of plasma cell-LTBMC interaction in the pathophysiology of MM.


Blood ◽  
2004 ◽  
Vol 104 (11) ◽  
pp. 3361-3361
Author(s):  
Teresa K. Kimlinger ◽  
Thomas E. Witzig ◽  
S. Vincent Rajkumar

Abstract Background: In previous studies quantitating VEGF receptors we have found no significant differences in expression between plasma cells from normal controls, multiple myeloma (MM), monoclonal gammopathy of undetermined significance (MGUS), or smoldering myeloma (SMM). (Kumar S, Blood, May 2004; 10.1182/blood-2003-11-3811 ePub). These studies were done using immunohistochemistry or Western Blotting (on CD138+ plasma cells) and may have been limited by low levels of receptor expression and by heterogeneity of expression. We measured expression of VEGF receptors (VEGFR1, VEGFR2 and VEGFR3) on the surface of plasma cells and in plasma cell subsets using direct and indirect flow cytometric assays to determine if significant differences in VEGF receptor expression existed between MGUS, SMM and MM. Methods: In the indirect flow cytometric assay, 32 bone marrow samples (3 amyloid, 9 MGUS, 12 MM, 8 SMM) were ACK lysed and tested using the FLUOROKINE TM rhVEGF biotin kit (R and D Systems, Minneapolis, MN) according to manufacturer’s instructions. In brief, in one tube (tube 1) cells were incubated with VEGF biotin. In tube 2, VEGF biotin preincubated with a blocking antibody was added to the cells (specificity control), while in a third tube a non-specific biotinylated protein (negative control) was added. After incubation, FITC-avidin, CD38 APC and CD45 Percp was added to each tube. Gates were drawn around the cells of interest and fitc staining was evaluated for the % positive cells. The % of signal blocked was calculated by comparing the fitc intensity (channel number) of the blocked VEGF peak (tube 2) to FITC intensity of tube 1. This system does not determine the identity of the receptor, but indicates the presence of VEGF receptors. In the direct flow cytometric assay, bone marrow from 25 individuals (2 amyloid, 5 MGUS, 7 MM, 7 SMM, and 4 normals) were lysed and blocked with mouse Ig and stained with CD38/CD45. In individual tubes, PE labeled VEGF R1, R2, R3 antibodies (R and D Systems, Minneapolis, MN) or isotype control were added. Plasma cells were identified, divided according to CD45 expression, and analyzed for % and intensity of receptor staining. Results: In the indirect assay, plasma cells in all groups bound VEGF ( 96% positive) at high intensity. There was also no difference in VEGF binding between CD45+ and CD45- plasma cell fractions (93 and 98% respectively).The specificity of VEGF binding (to one of the VEGF specific receptors) was confirmed by a significant drop in peak channel numbers of FITC intensity in the presence of blocking antibody. Specific VEGF binding at a similar intensity was seen in monocytes (95%) and at a lower intensity in lymphocytes (66%) and granulocytes (28%). Staining for VEGFR1, 2, and 3 in plasma cells using the direct assay revealed that except for 2 patients (1 amyloid and 1 SMM) none had >20% cells staining for any of the 3 receptors. The same results were seen in the CD45− fraction as well. In contrast, the CD45+ plasma cell fraction was highly positive for all 3 of the receptors in nearly all cases, with no significant differences between MGUS, SMM, amyloid, or MM. Conclusions: Plasma cells in MM and related disorders have specific VEGF receptors on the cell surface. The expression of VEGFR1, 2, and 3 seems to be primarily restricted to the CD 45+ subset of plasma cells. The finding of specific VEGF binding in CD45− plasma cells seen in the indirect assay may reflect the higher sensitivity of this assay due to the inbuilt amplification process or the presence of additional VEGF receptors such as neuropilin 1.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Zhongchuan W. Chen ◽  
Ioanna Kotsikogianni ◽  
Jay S. Raval ◽  
Christine G. Roth ◽  
Marian A. Rollins-Raval

Biclonal plasma cell myelomas producing two different isotypes of immunoglobulins are extremely rare entities; to date, the combination of IgD and IgM secretion by a biclonal plasma cell myeloma has not been reported. Bone marrow biopsy immunohistochemical studies in two cases revealed neoplastic plasma cells coexpressing IgD and IgM, but serum protein electrophoresis identified only the IgM monoclonal paraprotein in both cases. Biclonal plasma cell myelomas, while currently not well characterized in terms of their clinical behavior, should be distinguished from B-cell lymphoma with plasmacytic differentiation, given the different therapeutic implications. Both cases reported herein demonstrated chemotherapy-resistant clinical courses.


Sign in / Sign up

Export Citation Format

Share Document