scholarly journals Safe magnetic resonance scanning of patients with metallic middle ear implants

2006 ◽  
Vol 31 (6) ◽  
pp. 508-510 ◽  
Author(s):  
D.C. Wild ◽  
K. Head ◽  
D.A. Hall
Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 946
Author(s):  
Dong Ho Shin

This report describes the design of a new piezoelectric transducer for round window (RW)-driven middle ear implants. The transducer consists of a piezoelectric element, gold-coated copper bellows, silicone elastomer (polydimethylsiloxane, PDMS), metal cylinder (tungsten), and titanium housing. The piezoelectric element is fixed to the titanium housing and mechanical resonance is generated by the interaction of the bellows, PDMS, and tungsten cylinder. The dimensions of PDMS and the tungsten cylinder with output characteristics suitable for compensation of sensorineural hearing loss were derived by mechanical vibrational analysis (equivalent mechanical model and finite element analysis (FEA)). Based on the results of FEA, the RW piezoelectric transducer was implemented, and bench tests were performed under no-load conditions to confirm the output characteristics. The transducer generates an average displacement of 219.6 nm in the flat band (0.1–1 kHz); the resonance frequency is 2.3 kHz. To evaluate the output characteristics, the response was compared to that of an earlier transducer. When driven by the same voltage (6 Vp), the flat band displacement averaged 30 nm larger than that of the other transducer, and no anti-resonance was noted. Therefore, we expect that the new transducer can serve as an output device for hearing aids, and that it will improve speech recognition and treat high-frequency sensorineural hearing loss more effectively.


2016 ◽  
Vol 37 (7) ◽  
pp. e222-e227 ◽  
Author(s):  
Johannes Schnabl ◽  
Astrid Wolf-Magele ◽  
Stefan Marcel Pok ◽  
Lena Hirtler ◽  
Gertraud Heinz ◽  
...  

1986 ◽  
Vol 112 (6) ◽  
pp. 635-641 ◽  
Author(s):  
M. D. McGinn ◽  
R. A. Chole ◽  
S. P. Tinling

1997 ◽  
Vol 111 (3) ◽  
pp. 218-222 ◽  
Author(s):  
William W. Qiu ◽  
Shengguang S. Yin ◽  
Fred J. Stucker ◽  
Mardjohan Hardjasudarma

AbstractGlomus tumours involving the middle ear and the cerebellopontine angle are reported with emphasis on audiological findings. Magnetic resonance imaging (MRI), angiographic and pathological results are presented. Audiological tests, including impedance audiometry, evoked otoacoustic emissions and auditory brainstem responses, are valuable in evaluation of the effect of glomus tumours on the auditory system as well as their pathological extent.


1992 ◽  
Vol 106 (3) ◽  
pp. 261-269 ◽  
Author(s):  
Robert A. Goldenberg

Between 1987 and 1991, I have used 215 hydroxylapatite middle ear implants, in various styles, for hearing reconstruction. The first such implants were composed entirely of hydroxylapatite. Because of intraoperative difficulties in shaping and trimming these prostheses, hybrid prostheses using Plasti-Pore were developed. For each of four implant designs (incus, incus-stapes, PORP, and TORP), the head is constructed from hydroxylapatite and the shaft from Plasti-Pore. Extrusion rate for the hybrid prostheses is low (4.3%). Hearing results from 47 patients with the hybrid hydroxylapatite prostheses, 140 patients with total hydroxylapatite prostheses, and 75 control group patients with homograft bone or Plasti-Pore prostheses were compared. A “successful” hearing result was achieved in 51.1%, 51.4%, and 60.0% of the three groups, respectively. Surgical technique for use of the new hybrid hydroxylapatite prostheses is described.


1994 ◽  
pp. 680-680 ◽  
Author(s):  
N. P. Cohen ◽  
H. N. Whitfield ◽  
G. Dolke ◽  
Y. Y. Ng ◽  
P. Armstrong