Ex vivo comparison of digital images with conventional radiographs for detection of simulated voids in root canal filling material

2006 ◽  
Vol 39 (4) ◽  
pp. 287-292 ◽  
Author(s):  
S. Kositbowornchai ◽  
D. Hanwachirapong ◽  
R. Somsopon ◽  
S. Pirmsinthavee ◽  
N. Sooksuntisakoonchai
2017 ◽  
Vol 74 (4) ◽  
pp. 309
Author(s):  
Cristiane Ferreira Alfenas ◽  
Inês de Fátima De Azevedo Jacinto Inojosa ◽  
Júlio César De Azevedo Carvalhal ◽  
Mariana Teixeira Maneschy Faria ◽  
Fernanda Freitas Lins ◽  
...  

Objective: the aim of this study was to compare the amount of apically extruded debris during the removal of root canal filling material using nickel-titanium rotary retreatment instruments and Hedström files. Material and Methods: sixty mandibular incisors with a single canal were instrumented and obturated by cold lateral compaction. For retreatment, specimens were randomly divided into four groups (n = 15): Hedström files with or without solvent; D-RaCe system and Mtwo retreatment system. Debris extruded apically during the removal of canal filling material was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the preretreatment and postretreatment weight of the Eppendorf tubes for each group. The mean weights of extruded material were analyzed by one-way ANOVA. Results: the results showed that all retreatment techniques caused apical extrusion of debris, but no statistically significant difference was observed between groups (p>0.05). Conclusion: under the conditions of this study, all retreatment techniques caused apical debris extrusion.


2012 ◽  
Vol 45 (10) ◽  
pp. 927-932 ◽  
Author(s):  
B. Marques da Silva ◽  
F. Baratto-Filho ◽  
D. P. Leonardi ◽  
A. Henrique Borges ◽  
L. Volpato ◽  
...  

2012 ◽  
Vol 26 (0) ◽  
pp. 33-38
Author(s):  
Yuki Imamura ◽  
Miho Nakamura ◽  
Akiko Nagai ◽  
Yuzo Takagi ◽  
Kimihiro Yamashita

2021 ◽  
Vol 15 (1) ◽  
pp. 19-26
Author(s):  
Hala B. Kaka ◽  
Raid F. Salman

Abstract Background Three-dimensional obturation of the root canal system is mandatory for a successful root canal treatment. Using a filling material with optimal properties may enable the root canal to be sealed well and therefore obtain the desired obturation. Objective To develop a new injectable paste endodontic filling material using calcium phosphate powder and a styrene–butadiene emulsion polymer. Methods The powder phase comprised an equivalent molar ratio of tetracalcium phosphate, anhydrous dicalcium phosphate, bismuth oxide, and calcium chloride. The liquid phase comprised a styrene–butadiene rubber emulsion in distilled water. The powder and the liquid were mixed to achieve a paste consistency. The paste was subjected to various tests including flow, setting time, dimensional change, solubility, and radiopacity to indicate its suitability as a root canal filling material. All these tests were conducted according to the American National Standards Institute–American Dental Association for endodontic sealing materials. After passing these tests, the paste was submitted to an injectability test. Results The material showed acceptable flowability with 19.1 ± 1.3 min setting time and 0.61 ± 0.16% shrinkage after 30 days of storage. We found the highest solubility at 24 h (6.62 ± 0.58%), then the solubility decreased to 1.09 ± 0.08% within 3 days. The material was more radiopaque than a 3 mm step on an aluminum wedge. Furthermore, the material showed good injectability of 93.67 ± 1.80%. Conclusions The calcium phosphate powder in styrene–butadiene emulsion met basic requirements for a root canal filling material with promising properties.


2012 ◽  
Vol 23 (5) ◽  
pp. 608-611
Author(s):  
Ronaldo Araújo Souza ◽  
Yara T. Corrêa Silva-Sousa ◽  
Suely Colombo ◽  
Maurício Lago ◽  
Marco Antonio Hungaro Duarte ◽  
...  

Besides the risk of filling material extrusion throughout the apex, a satisfactory apical seal can be difficult to achieve in canals with open apices or iatrogenic enlargements of the apical constriction. These situations pose a challenge to root canal filling. This paper describes the root canal filling of a maxillary right canine with an overinstrumented apex, complete loss of the apical stop, extensive canal transportation and apical periodontitis. A 5 mm calcium hydroxide apical plug was placed before root canal filling. The plug was made by soaking paper points with saline, dipping the points in calcium hydroxide powder and then applying it to the apex several times, until a consistent apical plug was obtained. The canal was then irrigated with saline in order to remove any residual calcium hydroxide from the root canal walls, dried with paper points and obturated with an inverted #80 gutta-percha cone and zinc oxide-eugenol based sealer by the lateral condensation technique. An 8-year radiographic follow-up showed formation of mineralized tissue sealing the apical foramen, apical remodeling and no signs of apical periodontitis.


2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Soo-Hyuk Lee ◽  
Soram Oh ◽  
Adel Saeed Al-Ghamdi ◽  
Ayman Omar Mandorah ◽  
Kee-Yeon Kum ◽  
...  

The objective of root canal obturation is to achieve a fluid-tight seal. Recently, GuttaFlow bioseal (GB), a root canal sealer composed of polydimethylsiloxane, gutta-percha particles, and bioactive glass ceramics, has been developed, to enhance the sealing ability of root canal filling material. The objective of this study was to assess the sealing ability of GB using a subnanoliter-scaled fluid-flow measuring device and to compare with that of AH Plus (AH). The fluid flow in root canal-filled teeth using either gutta-percha cone (GP) with AH (GAR; n = 10) or GP with GB (GBR; n = 10) and in GP inserted in AH blocks (GA; n = 10) or GP inserted in GB blocks (GB; n = 10) was measured. In addition, fluid flow in sealer blocks of AH (A; n = 10) and GB (B; n = 10), which served as negative controls, was measured. Root canal-filled teeth using GP without any sealer (GR) acted as positive controls (n = 10). The leakage was obtained by calculating the volume of moved water by time (s), after stabilization of the fluid flow was achieved. Statistical analysis was performed using the Kruskal–Wallis test and Mann–Whitney U-test with Bonferroni correction. A p value less than 0.00238 (0.05/21) was considered significantly different. The mean leakages (nL/s) in the groups are as follows: GAR, 0.0958 ± 0.0543; GBR, 0.0223 ± 0.0246; GA, 0.0644 ± 0.0803; GB, 0.0267 ± 0.0182; A, 0.0055 ± 0.0057; B, 0.0052 ± 0.005; and GR, 0.2892 ± 0.3018. The mean leakage in the GBR group was lower than that in the GAR group (p = 0.001), while the mean leakages in the GA and GB groups were not significantly different. GuttaFlow bioseal can be useful in single-cone obturation technique.


1998 ◽  
Vol 14 (5) ◽  
pp. 199-205 ◽  
Author(s):  
R. Holland ◽  
J. A. Otoboni Filho ◽  
P. F. E. Bernabé ◽  
V. Souza ◽  
M. J. Nery ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document