ESTABLISHMENT OF REFERENCE INTERVALS OF PLATELET FUNCTION ANALYZER-100 CLOSURE TIMES IN HEALTHY KOREAN ADULTS

2007 ◽  
Vol 5 ◽  
pp. P-S-307-P-S-307
Author(s):  
H. Chung ◽  
Y. Cho ◽  
H. Chi ◽  
S. Jang ◽  
C. Park
PLoS ONE ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. e0249402
Author(s):  
Malika Belkacemi ◽  
Yassine Merad ◽  
Mohamed Amine Merbouh

Introduction The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simulates plug formation under high shear flow. The PFA-100 measures the time required to occlude the aperture in a biochemically active cartridge and is expressed in a term of closure time (CT). In Algeria, the reference values used in clinical laboratories are of Western origin. However, ethnic, genetic, dietary environmental, and diet differences between populations may affect reference intervals. We established the reference intervals of PFA-100 closure times in healthy Algerian adults according to the International Federation of Clinical Chemistry method, and we compared them with those of Western and Asian countries. Material and methods We enrolled 303 healthy blood donors in the study. 218 subjects met inclusion criteria. We analyzed the blood sample on the PFA-100 for CT with both the collagen epinephrine and collagen ADP cartridges. Results The reference intervals of PFA-100 collagen epinephrine CT and PFA-100 collagen ADP CT were 91–207 seconds and 71–144 seconds, respectively. Compared to Western and Asian populations, there were significant differences. The upper limits of CTs were higher for Algerians in this study. Our findings show that many healthy Algerians would be incorrectly identified as having a primary hemostasis abnormality according to the reference intervals of the manufacturer and scientific literature. Conclusion This report provides the first reference intervals for PFA-100 CTs in healthy Algerian adults. These results improve the accuracy of diagnosis and patient care in Algeria.


2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
Lulu Zhang ◽  
Xiaowei Hu ◽  
Juehua Zhu ◽  
Xiuying Cai ◽  
Yan Kong ◽  
...  

Background. The correlation between platelet function and recurrent ischemic stroke or TIA remains uncertain. Objective. To investigate two inductive agents to detect platelet functions and assess associations with recurrent ischemic stroke/TIA. Method. The study included 738 ischemic stroke/TIA patients. On days 0, 3, and 9 after antiplatelet therapy, platelet function tests were determined by maximum aggregation rate (MAR) using a PL-11 platelet function analyzer and phase matching reagents. Two induction agents were used: arachidonic acid (AA) and adenosine diphosphate (ADP). At 3-month follow-up, recurrence of stroke/TIA was recorded. Result. Cut-off values of adequate platelet function inhibition were MARADP < 35% and MARAA < 35%. Data showed that antiplatelet therapy could reduce the maximum aggregation rate. More importantly, adequate platelet function inhibition of either MARADP or MARAA was not associated with the recurrence of stroke/TIA, but adequate platelet function inhibition of not only MARADP but also MARAA predicts lower recurrence (0/121 (0.00%) versus 18/459 (3.92%), P = 0.0188). Conclusion. The platelet function tested by PL-11 demonstrated that adequate inhibition of both MARADP and MARAA could predict lower risk of ischemic stroke/TIA recurrence.


2005 ◽  
Vol 31 (04) ◽  
pp. 411-415 ◽  
Author(s):  
Martin Feuring ◽  
Armin Schultz ◽  
Ralf Losel ◽  
Martin Wehling

2005 ◽  
Vol 130 (5) ◽  
pp. 759-767 ◽  
Author(s):  
Hannelore Haubelt ◽  
Christof Anders ◽  
Anette Vogt ◽  
Petra Hoerdt ◽  
Ulrich Theo Seyfert ◽  
...  

2017 ◽  
Vol 44 (2) ◽  
pp. 106-113 ◽  
Author(s):  
Dejana Bogdanic ◽  
Nenad Karanovic ◽  
Jela Mratinovic-Mikulandra ◽  
Branka Paukovic-Sekulic ◽  
Dijana Brnic ◽  
...  

2005 ◽  
Vol 94 (12) ◽  
pp. 1213-1218 ◽  
Author(s):  
Marco Eugster ◽  
Walter H. Reinhart

SummaryPrimary haemostasis consists of platelet adhesion to subendothelial collagen, their activation and aggregation and finally the formation of a platelet plug. Erythrocytes are involved in this process because they flow in the center of the vessel and push platelets towards the site of action on the vessel wall and enhance shear forces, which activate platelets. In the platelet function analyzer PFA-100® (Dade Behring, Düdingen, Switzerland), the in vivo situation is simulated in vitro with blood being aspirated at high shear rates (5000s-1) through a capillary into a membrane pore with a diameter of 150 μm coated with type I collagen and either epinephrine or adenosine diphosphate. Aggregating platelets plug the pore and stop the flow, which is measured as the closure time. We analysed the influence of erythrocytes on platelet function analyzer measurements by systematic variation of the haematocrit (20,30,40,and 50%) at constant platelet counts of 289±61 ×103/μl plasma, or 152±30 ×103/μl blood, 96±9 ×103/μl blood and 54±5 ×103/μl blood, respectively. An inverse correlation was found between haematocrit and closure time under all circumstances. A decrease of the platelet count by 50 ×103 /μl could be compensated for by a 10% increase in haematocrit. The haematocrit must, therefore, be taken into consideration for the correct interpretation of PFA-100® measurements. Our data also provide a pathophysiological rationale to reduce the risk of bleeding in patients with thrombocytopenia and anaemia by normalizing the haematocrit with erythrocyte transfusions.