scholarly journals Intranasal Fentanyl and High-concentration Inhaled Nitrous Oxide for Procedural Sedation: A Prospective Observational Pilot Study of Adverse Events and Depth of Sedation

2012 ◽  
Vol 19 (1) ◽  
pp. 31-36 ◽  
Author(s):  
Robert W. Seith ◽  
Theane Theophilos ◽  
Franz E. Babl
PEDIATRICS ◽  
2008 ◽  
Vol 121 (3) ◽  
pp. e528-e532 ◽  
Author(s):  
F. E. Babl ◽  
E. Oakley ◽  
C. Seaman ◽  
P. Barnett ◽  
L. N. Sharwood

The Lancet ◽  
2001 ◽  
Vol 358 (9292) ◽  
pp. 1514-1515 ◽  
Author(s):  
Olivier Gall ◽  
Daniel Annequin ◽  
Guy Benoit ◽  
Emmanuel Van Glabeke ◽  
Françoise Vrancea ◽  
...  

2019 ◽  
Vol 14 (1) ◽  
pp. 31-36
Author(s):  
Raafat Abdel-Malek ◽  
Kyrillus S. Shohdy ◽  
Noha Abbas ◽  
Mohamed Ismail ◽  
Emad Hamada ◽  
...  

Background: Several single chemotherapeutic agents have been evaluated as the second-line treatment of advanced urothelial carcinoma. Despite encouraging efficacy outcomes, toxicity has often led to dose modifications or discontinuation. We aimed to assess the safety of vinflunine in a particular population of advanced transitional cell carcinoma of urothelium (TCCU), that were exposed to the previous toxicity of chemotherapy. Methods: This is an open-label, prospective, single-center pilot study to evaluate the response rate and safety profile of vinflunine in patients with advanced TCCU. It was planned to enroll 25 evaluable patients. Eligible patients are those with progressive disease after first-line platinum-based regimen for advanced or metastatic disease. Results: The study was prematurely closed due to two sudden deaths that were judged by the review board as treatment-related. Only ten patients were evaluated and received at least one cycle of vinflunine. All but one were male and seven underwent radical surgery. Eight had a distant metastasis (mainly lung and/or liver). Disease control rate was 40%, four patients had a partial response with median duration of response of 3.5 months. The median overall survival was 3.2 months (95% CI:1.67- 4.73). There were three serious adverse events namely two sudden deaths and one grade 4 thrombocytopenia. Nine grade 3/4 adverse events occurred. The most common all-grade adverse events were fatigue (50%), constipation (40%) and vomiting (40%). Moreover, grade 3 fatigue occurred in 30% of patients. Only one patient, who achieved PR for 5 months, was fit to receive further cytotoxic chemotherapy. Conclusion: The activity of vinflunine in advanced urothelial carcinoma came at the expense of its safety. The use of vinflunine has to be limited to the selected group of patients. However, this is a single institute experience in a limited number of patients.


2020 ◽  
Vol 61 (6) ◽  
pp. 153-162
Author(s):  
Julia H.E. Houtzager ◽  
Sebastiaan David Hemelrijk ◽  
Ivo C.J.H. Post ◽  
Mirza M Idu ◽  
Frederike J. Bemelman ◽  
...  

Background: The shortage of donor kidneys has led to the use of marginal donors, e.g., those whose kidneys are donated after circulatory death. Preservation of the graft by hypothermic machine perfusion (HMP) provides a viable solution to reduce warm ischemic damage. This pilot study was undertaken to assess the feasibility and patient safety of the AirdriveTM HMP system in clinical kidney transplantation. Methods: Five deceased-donor kidneys were preserved using the oxygenated Airdrive HMP system between arrival at the recipient center (Amsterdam UMC) and implantation in the patient. The main study end-points were adverse effects due to the use of Airdrive HMP. Secondary end-points were clinical outcomes and perfusion parameters. All events occurring during the transplantation procedure or within 1 month of follow-up were monitored. Results: Five patients were included in this pilot study. No technical failures were observed during the preservation period using the Airdrive HMP. Mean perfusion parameters were: duration 8.5 h (3–15 h), pressure 25 mm Hg (18–25 mm Hg), flow 49.77 mL/min (19–58 mL/min), resistance 0.57 mm Hg/min/mL (0.34–1.3 mm Hg/min/mL), and temperature 8.2 °C (2–13°C). Mean cold ischemia time (CIT) was 20.2 h (11–29.5 h). No adverse events or technical failures were observed during preservation and transplantation or during the 1-month follow-up. Conclusions: This pilot study showed the feasibility of the use of the Airdrive HMP system with no adverse events in clinical kidney transplantation.


Sign in / Sign up

Export Citation Format

Share Document