Quantification of stratum corneum removal by adhesive tape stripping by total protein assay in 96-well microplates

2005 ◽  
Vol 11 (2) ◽  
pp. 97-101 ◽  
Author(s):  
F. Dreher ◽  
B. S. Modjtahedi ◽  
S. P. Modjtahedi ◽  
H. I. Maibach
2005 ◽  
Vol 33 (3) ◽  
pp. 207-213 ◽  
Author(s):  
Paul J. Dierickx

In our previously described Hep G2/24-hour/total protein assay, protein levels were measured by using the Lowry method. This assay was the best acute in vitro assay for the prediction of human toxicity within the Multicentre Evaluation of In Vitro Cytotoxicity (MEIC) study. In order to increase the MEIC data-base with a wider range of chemicals, we were interested in introducing the more practical 3-(4-carboxybenzoyl)-quinoline-2-carboxaldehyde (CBQCA) method for the quantification of the total protein content. Therefore, we investigated whether the same good results for the prediction of acute human toxicity would be obtained with the CBQCA method. The cells were treated for 24 hours, then cytotoxicity was determined by measuring the total protein content with CBQCA. The results were quantified by using the PI50c: the concentration (in mM) of test compound required to reduce the total protein content measured with the CBQCA-method by 50% as compared to the control cells. The results were compared with the PI50, the corresponding value when the Lowry method was used. A relatively low correlation was observed between PI50 and PI50c, reflecting the large and unexpected, differences when using the two protein assays. However, when comparing the log PI50c with the human toxicity, a correlation coefficient of r2 = 0.761 ( n = 44) was obtained for exactly the same series of MEIC chemicals. This value is clearly higher than that for the Lowry method ( r2 = 0.695). Compared to the Lowry method originally used, the Hep G2/24-hour/CBQCA total protein assay has the additional important advantage that it can be very easily adapted for large-scale analyses with robotic systems, including the on-line calculation of the results.


1991 ◽  
Vol 68 (1-3) ◽  
pp. 127-133 ◽  
Author(s):  
Tsai Jui-Chen ◽  
Markus J. Cappel ◽  
Norman D. Weiner ◽  
Gordon L. Flynn ◽  
James Ferry

1987 ◽  
Vol 33 (11) ◽  
pp. 2089-2092 ◽  
Author(s):  
E G Lentjes ◽  
G A Harff ◽  
E T Backer

Abstract We evaluated the analytical performance of the Hitachi 704 automatic analyzer. The spectrophotometer showed a linearity of response at 340 nm up to 2.8 A. Photometric imprecision measured bichromatically at 340 and 376 nm was 0.49% at 0.16 A, 0.14% at 0.46 A, and 0.17% at 0.76 A. Imprecision of the sample probe was 0.4% for 5, 10, and 20 microL, and the volume delivered deviated -2.4%, -4.4%, and -4.2% from these preset volumes, respectively. Imprecision of the reagent probe over the range 50 to 500 microL ranged from 0.14% to 0.29%; volume delivered deviated from +1.7% to +4.4%). At equilibrium, the temperature in the cuvets was 29.8 (SD 0.05) degree C as measured by cresol red spectrophotometry. No sample carryover was detected. Reagent carryover was detected when a bilirubin assay was preceded by a total protein assay and when lactate dehydrogenase was measured after alanine aminotransferase. Imprecision for nine tests at three concentrations ranged from 1.1% to 4.4%. Comparison of methods with the SMAC II as reference method showed good results. Precision was better than reported for the Hitachi 705 automatic analyzer.


2012 ◽  
pp. 262-267
Author(s):  
Kaley A. Myer ◽  
Frank Dreher ◽  
Alessandra Pelosi ◽  
Kazuhiro Mio ◽  
Enzo Berardesca ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document