Microwave thermography: a non-invasive technique for investigation of injury of the superficial digital flexor tendon in the horse

1992 ◽  
Vol 24 (4) ◽  
pp. 269-273 ◽  
Author(s):  
CELIA M. MARR
2020 ◽  
Vol 21 (6) ◽  
pp. 2150
Author(s):  
Nai-Hao Yin ◽  
Anthony W. Parker ◽  
Pavel Matousek ◽  
Helen L. Birch

The lack of clinical detection tools at the molecular level hinders our progression in preventing age-related tendon pathologies. Raman spectroscopy can rapidly and non-invasively detect tissue molecular compositions and has great potential for in vivo applications. In biological tissues, a highly fluorescent background masks the Raman spectral features and is usually removed during data processing, but including this background could help age differentiation since fluorescence level in tendons increases with age. Therefore, we conducted a stepwise analysis of fluorescence and Raman combined spectra for better understanding of the chemical differences between young and old tendons. Spectra were collected from random locations of vacuum-dried young and old equine tendon samples (superficial digital flexor tendon (SDFT) and deep digital flexor tendon (DDFT), total n = 15) under identical instrumental settings. The fluorescence-Raman spectra showed an increase in old tendons as expected. Normalising the fluorescence-Raman spectra further indicated a potential change in intra-tendinous fluorophores as tendon ages. After fluorescence removal, the pure Raman spectra demonstrated between-group differences in CH2 bending (1450 cm−1) and various ring-structure and carbohydrate-associated bands (1000–1100 cm−1), possibly relating to a decline in cellular numbers and an accumulation of advanced glycation end products in old tendons. These results demonstrated that Raman spectroscopy can successfully detect age-related tendon molecular differences.


2014 ◽  
pp. 9-18
Author(s):  
Thi Linh Giang Truong ◽  
Vu Quoc Huy Nguyen

Background: Assessment of fetal health plays the most important role in prenatal care because of influence of the prediction of gestational outcome. One of the main aims of routine antenatal care is to identify the ‘ at risk ‘ fetus in order to apply clinical interventions which could results in reduced perinatal morbidity and mortality. Doppler ultrasound is a non invasive technique whereby the movement of blood is studied by detecting the change in frequence of reflected sound, Doppler blood flow velocity waves form of fetal side (umbilical artery, middle cerebral artery ...) and maternal side ( uterine arteries) are discussed and monograms for routine practice are presented. Recently this method is important tool for qualifying high risk pregnancies and help early forecasts the health of the babies and mothers disorder. Doppler sonography in obstetrics is a widely accepted functional method of examining the prediction of gestational outcome. Key words: Doppler, umbilical artery, middle cerebral artery, uterine arteries


2020 ◽  
Vol 11 (1) ◽  
pp. 25
Author(s):  
Sonia Hermoso-Durán ◽  
Guillermo García-Rayado ◽  
Laura Ceballos-Laita ◽  
Carlos Sostres ◽  
Sonia Vega ◽  
...  

Background: Current efforts in the identification of new biomarkers are directed towards an accurate differentiation between benign and premalignant cysts. Thermal Liquid Biopsy (TLB) has been previously applied to inflammatory and tumor diseases and could offer an interesting point of view in this type of pathology. Methods: In this work, twenty patients (12 males and 8 females, average ages 62) diagnosed with a pancreatic cyst benign (10) and premalignant (10) cyst lesions were recruited, and biological samples were obtained during the endoscopic ultrasonography procedure. Results: Proteomic content of cyst liquid samples was studied and several common proteins in the different groups were identified. TLB cyst liquid profiles reflected protein content. Also, TLB serum score was able to discriminate between healthy and cysts patients (71% sensitivity and 98% specificity) and between benign and premalignant cysts (75% sensitivity and 67% specificity). Conclusions: TLB analysis of plasmatic serum sample, a quick, simple and non-invasive technique that can be easily implemented, reports valuable information on the observed pancreatic lesion. These preliminary results set the basis for a larger study to refine TLB serum score and move closer to the clinical application of TLB providing useful information to the gastroenterologist during patient diagnosis.


2021 ◽  
Vol 224 (2) ◽  
pp. S182-S183
Author(s):  
Zaid Diken ◽  
Antonio F. Saad ◽  
Sema Hajmurad ◽  
Rakesh Vadhera ◽  
Michelle Simon ◽  
...  

1992 ◽  
Vol 24 (1) ◽  
pp. 46-51 ◽  
Author(s):  
ANN E. KRAUS-HANSEN ◽  
G. E. FACKELMAN ◽  
C. BECKER ◽  
R. M. WILLIAMS ◽  
F. S. PIPERS

2017 ◽  
Vol 181 (24) ◽  
pp. 655-655 ◽  
Author(s):  
Rafael Alzola Domingo ◽  
Chris M Riggs ◽  
David S Gardner ◽  
Sarah L Freeman

Superficial digital flexor tendon (SDFT) tendinopathy is an important musculoskeletal problem in horses. The study objective was to validate an ultrasonographic scoring system for SDFT injuries. Ultrasonographic images from 14 Thoroughbred racehorses with SDFT lesions (seven core; seven diffuse) and two controls were blindly assessed by five clinicians on two occasions. Ultrasonographic parameters evaluated were: type and extent of the injury, location, echogenicity, cross-sectional area and longitudinal fibre pattern of the maximal injury zone (MIZ). Inter-rater variability and intra-rater reliability were assessed using Kendall’s coefficient of concordance (KC) and Lin’s concordance correlation coefficient (LC), respectively. Type of injury (core vs. diffuse) had perfect inter/intra-rater agreement. Cases with core lesions had very strong inter-rater agreement (KC ≥0.74, P<0.001) and intra-rater reliability (LC ≥0.73) for all parameters apart from echogenicity. Cases with diffuse lesions had strong inter-rater agreement (KC ≥0.62) for all parameters, but weak agreement for echogenicity (KC=0.22); intra-rater reliability was excellent for MIZ location and fibre pattern (LC ≥0.82), and moderate (LC ≥0.58) for cross-sectional area and number of zones affected. This scoring system was reliable and repeatable for all parameters, except for echogenicity. A validated scoring system will facilitate reliable recording of SDFT injuries and inter-study meta-analyses.


Sign in / Sign up

Export Citation Format

Share Document