Impact of automated dispensing cabinets on medication selection and preparation error rates in an emergency department: a prospective and direct observational before-and-after study

2015 ◽  
Vol 22 (2) ◽  
pp. 156-163 ◽  
Author(s):  
Laura Fanning ◽  
Nick Jones ◽  
Elizabeth Manias
2015 ◽  
Vol 56 (5) ◽  
pp. 1428 ◽  
Author(s):  
Won Chul Cha ◽  
Kyoung Jun Song ◽  
Jin Sung Cho ◽  
Adam J. Singer ◽  
Sang Do Shin

2020 ◽  
Vol 27 (3) ◽  
pp. e100170
Author(s):  
Johanna I Westbrook ◽  
Neroli S Sunderland ◽  
Amanda Woods ◽  
Magda Z Raban ◽  
Peter Gates ◽  
...  

BackgroundElectronic medication systems (EMS) have been highly effective in reducing prescribing errors, but little research has investigated their effects on medication administration errors (MAEs).ObjectiveTo assess changes in MAE rates and types associated with EMS implementation.MethodsThis was a controlled before and after study (three intervention and three control wards) at two adult teaching hospitals. Intervention wards used an EMS with no bar-coding. Independent, trained observers shadowed nurses and recorded medications administered and compliance with 10 safety procedures. Observational data were compared against medication charts to identify errors (eg, wrong dose). Potential error severity was classified on a 5-point scale, with those scoring ≥3 identified as serious. Changes in MAE rates preintervention and postintervention by study group, accounting for differences at baseline, were calculated.Results7451 administrations were observed (4176 pre-EMS and 3275 post-EMS). At baseline, 30.2% of administrations contained ≥1 MAE, with wrong intravenous rate, timing, volume and dose the most frequent. Post-EMS, MAEs decreased on intervention wards relative to control wards by 4.2 errors per 100 administrations (95% CI 0.2 to 8.3; p=0.04). Wrong timing errors alone decreased by 3.4 per 100 administrations (95% CI 0.01 to 6.7; p<0.05). EMS use was associated with an absolute decline in potentially serious MAEs by 2.4% (95% CI 0.8 to 3.9; p=0.003), a 56% reduction in the proportion of potentially serious MAEs. At baseline, 74.1% of administrations were non-compliant with ≥1 of 10 procedures and this rate did not significantly improve post-EMS.ConclusionsImplementation of EMS was associated with a modest, but significant, reduction in overall MAE rate, but halved the proportion of MAEs rated as potentially serious.


2012 ◽  
Vol 43 (1) ◽  
pp. 29-37 ◽  
Author(s):  
Judith Finn ◽  
Amanda Rae ◽  
Nick Gibson ◽  
Roger Swift ◽  
Tamara Watters ◽  
...  

2020 ◽  
Vol 11 (02) ◽  
pp. 323-335 ◽  
Author(s):  
Moninne M. Howlett ◽  
Eileen Butler ◽  
Karen M. Lavelle ◽  
Brian J. Cleary ◽  
Cormac V. Breatnach

Abstract Background Increased use of health information technology (HIT) has been advocated as a medication error reduction strategy. Evidence of its benefits in the pediatric setting remains limited. In 2012, electronic prescribing (ICCA, Philips, United Kingdom) and standard concentration infusions (SCIs)—facilitated by smart-pump technology—were introduced into the pediatric intensive care unit (PICU) of an Irish tertiary-care pediatric hospital. Objective The aim of this study is to assess the impact of the new technology on the rate and severity of PICU prescribing errors and identify technology-generated errors. Methods A retrospective, before and after study design, was employed. Medication orders were reviewed over 24 weeks distributed across four time periods: preimplementation (Epoch 1); postimplementation of SCIs (Epoch 2); immediate postimplementation of electronic prescribing (Epoch 3); and 1 year postimplementation (Epoch 4). Only orders reviewed by a clinical pharmacist were included. Prespecified definitions, multidisciplinary consensus and validated grading methods were utilized. Results A total of 3,356 medication orders for 288 patients were included. Overall error rates were similar in Epoch 1 and 4 (10.2 vs. 9.8%; p = 0.8), but error types differed (p < 0.001). Incomplete and wrong unit errors were eradicated; duplicate orders increased. Dosing errors remained most common. A total of 27% of postimplementation errors were technology-generated. Implementation of SCIs alone was associated with significant reductions in infusion-related prescribing errors (29.0% [Epoch 1] to 14.6% [Epoch 2]; p < 0.001). Further reductions (8.4% [Epoch 4]) were identified after implementation of electronically generated infusion orders. Non-infusion error severity was unchanged (p = 0.13); fewer infusion errors reached the patient (p < 0.01). No errors causing harm were identified. Conclusion The limitations of electronic prescribing in reducing overall prescribing errors in PICU have been demonstrated. The replacement of weight-based infusions with SCIs was associated with significant reductions in infusion prescribing errors. Technology-generated errors were common, highlighting the need for on-going research on HIT implementation in pediatric settings.


2012 ◽  
pp. 2869-2885
Author(s):  
Judith C. Finn ◽  
Amanda Rae ◽  
Nick Gibson ◽  
Roger Swift ◽  
Tamara Watters ◽  
...  

PLoS Medicine ◽  
2012 ◽  
Vol 9 (1) ◽  
pp. e1001164 ◽  
Author(s):  
Johanna I. Westbrook ◽  
Margaret Reckmann ◽  
Ling Li ◽  
William B. Runciman ◽  
Rosemary Burke ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document