Development of New Single and High-Density Heat-Flux Gauges for Unsteady Heat Transfer Measurements for a Rotating Transonic Turbine

2021 ◽  
Author(s):  
Richard Celestina ◽  
Spencer Sperling ◽  
Louis Christensen ◽  
Randall Mathison ◽  
Hakan Aksoy ◽  
...  
Author(s):  
Richard Celestina ◽  
Spencer Sperling ◽  
Louis Christensen ◽  
Randall Mathison ◽  
Hakan Aksoy ◽  
...  

Abstract This paper presents the development and implementation of a new generation of double-sided heat-flux gauges at The Ohio State University Gas Turbine Laboratory (GTL) along with heat transfer measurements for film-cooled airfoils in a single-stage high-pressure transonic turbine operating at design corrected conditions. Double-sided heat flux gauges are a critical part of turbine cooling studies, and the new generation improves upon the durability and stability of previous designs while also introducing high-density layouts that provide better spatial resolution. These new customizable high-density double-sided heat flux gauges allow for multiple heat transfer measurements in a small geometric area such as immediately downstream of a row of cooling holes on an airfoil. Two high-density designs are utilized: Type A consists of 9 gauges laid out within a 5 mm by 2.6 mm (0.20 inch by 0.10 inch) area on the pressure surface of an airfoil, and Type B consists of 7 gauges located at points of predicted interest on the suction surface. Both individual and high-density heat flux gauges are installed on the blades of a transonic turbine experiment for the second build of the High-Pressure Turbine Innovative Cooling program (HPTIC2). Run in a short duration facility, the single-stage high-pressure turbine operated at design-corrected conditions (matching corrected speed, flow function, and pressure ratio) with forward and aft purge flow and film-cooled blades. Gauges are placed at repeated locations across different cooling schemes in a rainbow rotor configuration. Airfoil film-cooling schemes include round, fan, and advanced shaped cooling holes in addition to uncooled airfoils. Both the pressure and suction surfaces of the airfoils are instrumented at multiple wetted distance locations and percent spans from roughly 10% to 90%. Results from these tests are presented as both time-average values and time-accurate ensemble averages in order to capture unsteady motion and heat transfer distribution created by strong secondary flows and cooling flows.


2008 ◽  
Vol 130 (3) ◽  
Author(s):  
A. de la Loma ◽  
G. Paniagua ◽  
D. Verrastro ◽  
P. Adami

This paper reports the external convective heat transfer distribution of a modern single-stage transonic turbine together with the physical interpretation of the different shock interaction mechanisms. The measurements have been performed in the compression tube test rig of the von Karman Institute using single- and double-layered thin film gauges. The three pressure ratios tested are representative of those encountered in actual aeroengines, with M2,is ranging from 1.07 to 1.25 and a Reynolds number of about 106. Three different rotor blade heights (15%, 50%, and 85%) and the stator blade at midspan have been investigated. The measurements highlight the destabilizing effect of the vane left-running shock on the rotor boundary layer. The stator unsteady heat transfer is dominated by the fluctuating right-running vane trailing edge shock at the blade passing frequency.


Author(s):  
A. C. Smith ◽  
A. C. Nix ◽  
T. E. Diller ◽  
W. F. Ng

This paper documents the measurement of the unsteady effects of passing shock waves on film cooling heat transfer on both the pressure and suction surfaces of first stage transonic turbine blades with leading edge showerhead film cooling. Experiments were performed for several cooling blowing ratios with an emphasis on time-resolved pressure and heat flux measurements on the pressure surface. Results without film cooling on the pressure surface demonstrated that increases in heat flux were a result of shock heating (the increase in temperature across the shock wave) rather than shock interaction with the boundary layer or film layer. Time-resolved measurements with film cooling demonstrated that the relatively strong shock wave along the suction surface appears to retard coolant ejection there and causes excess coolant to be ejected from pressure surface holes. This actually causes a decrease in heat transfer on the pressure surface during a large portion of the shock passing event. The magnitude of the decrease is almost as large as the increase in heat transfer without film cooling. The decrease in coolant ejection from the suction surface holes did not appear to have any effects on suction surface heat transfer.


Author(s):  
D. G. Holmberg ◽  
T. Reid ◽  
T. Kiss ◽  
H. L. Moses ◽  
W. F. Ng ◽  
...  

Results from a new facility for measuring heat transfer in transonic turbine cascades are repotted. An air heater has been built into the blow-down wind tunnel to heat the main flow for a 20 second run time. This allows control of the direction and magnitude of the heat transfer into the blade throughout the tests. A Heat Flux Microsensor was inserted into the blade to measure simultaneous surface heat flux and temperature. Measurements were made on the suction surface of the blades toward the trailing edge. Because of the long run times (20 s), the adiabatic wall temperature could be determined directly from the measured surface temperature and heat flux. Simultaneous pressure measurements were made with a Kulite transducer at the same distance from the leading edge to document shock passage. A separate shock tube was used to generate a shock wave which was introduced into the test section in front of the cascade. This shock was carried over the blade by the main flow. The resulting changes in heat flux correlated strongly with the unsteady pressure changes. An overall increase of 1.5 W/cm2 in heat flux was recorded for a pressure increase of 7 kPa during the initial passage of the shock.


Author(s):  
A. de la Loma ◽  
G. Paniagua ◽  
D. Verrastro ◽  
P. Adami

This paper reports the external convective heat transfer distribution of a modern single-stage transonic turbine together with the physical interpretation of the different shock interaction mechanisms. The measurements have been performed in the compression tube test rig of the von Karman Institute using single and double-layered thin film gauges. The three pressure ratios tested are representative of those encountered in actual aero-engines, with M2, is ranging from 1.07 to 1.25 and a Reynolds number of about 106. Three different rotor blade heights (15%, 50% and 85%) and the stator blade at mid-span have been investigated. The measurements highlight the destabilizing effect of the vane left running shock on the rotor boundary layer. The stator unsteady heat transfer is dominated by the fluctuating right running vane trailing edge shock at the blade passing frequency.