Recommendations for Achieving Accurate Numerical Simulation of Tip Clearance Flows in Transonic Compressor Rotors

1999 ◽  
Vol 122 (4) ◽  
pp. 733-742 ◽  
Author(s):  
Dale E. Van Zante ◽  
Anthony J. Strazisar ◽  
Jerry R. Wood ◽  
Michael D. Hathaway ◽  
Theodore H. Okiishi

The tip clearance flows of transonic compressor rotors are important because they have a significant impact on rotor and stage performance. A wall-bounded shear layer formed by the relative motion between the overtip leakage flow and the shroud wall is found to have a major influence on the development of the tip clearance flow field. This shear layer, which has not been recognized by earlier investigators, impacts the stable operating range of the rotor. Simulation accuracy is dependent on the ability of the numerical code to resolve this layer. While numerical simulations of these flows are quite sophisticated, they are seldom verified through rigorous comparisons of numerical and measured data because these kinds of measurements are rare in the detail necessary to be useful in high-speed machines. In this paper we compare measured tip-clearance flow details (e.g., trajectory and radial extent) with corresponding data obtained from a numerical simulation. Laser-Doppler Velocimeter (LDV) measurements acquired in a transonic compressor rotor, NASA Rotor 35, are used. The tip clearance flow field of this transonic rotor is simulated using a Navier–Stokes turbomachinery solver that incorporates an advanced k–ε turbulence model derived for flows that are not in local equilibrium. A simple method is presented for determining when the wall-bounded shear layer is an important component of the tip clearance flow field. [S0889-504X(00)02504-6]

Author(s):  
Dale E. Van Zante ◽  
Anthony J. Strazisar ◽  
Jerry R. Wood ◽  
Michael D. Hathaway ◽  
Theodore H. Okiishi

The tip clearance flows of transonic compressor rotors are important because they have a significant impact on rotor and stage performance. While numerical simulations of these flows are quite sophisticated, they are seldom verified through rigorous comparisons of numerical and measured data because these kinds of measurements are rare in the detail necessary to be useful in high-speed machines. In this paper we compare measured tip-clearance flow details (e.g. trajectory and radial extent) with corresponding data obtained from a numerical simulation. Recommendations for achieving accurate numerical simulation of tip clearance flows are presented based on this comparison. Laser Doppler Velocimeter (LDV) measurements acquired in a transonic compressor rotor, NASA Rotor 35, are used. The tip clearance flow field of this transonic rotor was simulated using a Navier-Stokes turbomachinery solver that incorporates an advanced k-ε turbulence model derived for flows that are not in local equilibrium. Comparison between measured and simulated results indicates that simulation accuracy is primarily dependent upon the ability of the numerical code to resolve important details of a wall-bounded shear layer formed by the relative motion between the over-tip leakage flow and the shroud wall. A simple method is presented for determining the strength of this shear layer.


Author(s):  
Chunill Hah ◽  
Melanie Voges ◽  
Martin Mueller ◽  
Heinz-Peter Schiffer

In the present study, unsteady flow phenomena due to tip clearance flow instability in a modern transonic axial compressor rotor are studied in detail. First, unsteady flow characteristics due the oscillating tip clearance vortex measured with the particle image velocimetry (PIV) and casing-mounted unsteady pressure transducers are analyzed and compared to numerical results with a large eddy simulation (LES). Then, measured characteristic frequencies of the unsteady flow near stall operation are investigated. The overall purpose of the study is to advance the current understanding of the unsteady flow field near the blade tip in an axial transonic compressor rotor near the stall operating condition. Flow interaction between the tip leakage vortex and the passage shock is inherently unsteady in a transonic compressor. The currently applied PIV measurements indicate that the flow near the tip region is unsteady even at the design condition. This self-induced unsteadiness increases significantly as the compressor operates toward the stall condition. PIV data show that the tip clearance vortex oscillates substantially near stall. The calculated unsteady characteristics from LES agree well with the PIV measurements. Calculated unsteady flow fields show that the formation of the tip clearance vortex is intermittent and the concept of vortex breakdown from steady flow analysis does not seem to apply in the current flow field. Fluid with low momentum near the pressure side of the blade close to the leading edge periodically spills over into the adjacent blade passage. The spectral analysis of measured end wall and blade surface pressure shows that there are two dominant frequencies near stall. One frequency is about 40–60% of the rotor rotation and the other dominant frequency is about 40–60% of the blade passing frequency (BPF). The first frequency represents the movement of a large blockage over several consecutive blade passages against the rotor rotation. The second frequency represents traditional tip flow instability, which has been widely observed in subsonic compressors. The LES simulations show that the second frequency is due to movement of the instability vortex.


1994 ◽  
Author(s):  
D. Muthuvel Murugan ◽  
Widen Tabakoff ◽  
Awatef Hamed

Detailed flow investigation in the downstream region of a radial inflow turbine has been performed using a three component Laser Doppler Velocimetry. The flow velocities are measured in the exit region of the turbine at off-design operating conditions. The results are presented as contour and vector plots of mean velocities, flow angles and turbulent stresses. The measured parameters are correlated to the rotor blade rotation to observe any periodic nature of the flow. The measurements reveal a complex flow pattern near the tip region at the rotor exit due to the interaction of the tip clearance flow. The degree of swirl of the flow near the tip region at the rotor exit is observed to be high due to the gross under turning of the flow near the tip region. The effect of the rotor on the exit flow field is observed in the proximity of the rotor exit.


Author(s):  
Daniel Möller ◽  
Maximilian Jüngst ◽  
Felix Holzinger ◽  
Christoph Brandstetter ◽  
Heinz-Peter Schiffer ◽  
...  

A flutter phenomenon was observed in a 1.5-stage configuration at the Darmstadt transonic compressor. This phenomenon is investigated numerically for different compressor speeds. The flutter occurs for the second eigenmode of the rotor blades and is caused by tip clearance flow which is able to pass through multiple rotor gaps at highly throttled operating points. The vibration pattern during flutter is accompanied by a pressure fluctuation pattern of the tip clearance flow which is interacting with the blade motion causing the aeroelastic instability. The velocity of the tip clearance flow fluctuation is about 50% of the blade tip speed for simulation and experiment and also matches the mean convective velocity inside the rotor gap. This is consistent for all compressor speeds. From this investigations, general guidelines are drawn which can be applied at an early stage during compressor design to evaluate the susceptibility to this kind of blade vibration.


2014 ◽  
Vol 137 (4) ◽  
Author(s):  
S. Saddoughi ◽  
G. Bennett ◽  
M. Boespflug ◽  
S. L. Puterbaugh ◽  
A. R. Wadia

Blade tip losses represent a major performance penalty in low aspect ratio transonic compressors. This paper reports on the experimental evaluation of the impact of tip clearance with and without plasma actuator flow control on performance of an U.S. Air Force-designed low aspect ratio, high radius ratio single-stage transonic compressor rig. The detailed stage performance measurements without flow control at three clearance levels, classified as small, medium, and large, are presented. At design-speed, increasing the clearance from small to medium resulted in a stage peak efficiency drop of almost six points with another four point drop in efficiency with the large clearance (LC). Comparison of the speed lines at high-speed show significantly lower pressure rise with increasing tip clearance, the compressor losing 8% stall margin (SM) with medium clearance (MC) and an additional 1% with the LC. Comparison of the stage exit radial profiles of total pressure and adiabatic efficiency at both part-speed and design-speed and with throttling are presented. Tip clearance flow-control was investigated using dielectric barrier discharge (DBD) type plasma actuators. The plasma actuators were placed on the casing wall upstream of the rotor leading edge and the compressor mapped from part-speed to high-speed at three clearances with both axial and skewed configurations at six different frequency levels. The plasma actuators did not impact steady state performance. A maximum SM improvement of 4% was recorded in this test series. The LC configuration benefited the most with the plasma actuators. Increased voltage provided more SM improvement. Plasma actuator power requirements were almost halved going from continuous operation to pulsed plasma. Most of the improvement with the plasma actuators is attributed to the reduction in unsteadiness of the tip clearance vortex near-stall resulting in additional reduction in flow prior to stall.


Author(s):  
Masahiro Inoue ◽  
Masato Furukawa

In a recent advanced aerodynamic design of turbomachinery, the physical interpretation of three-dimensional flow field obtained by a numerical simulation is important for iterative modifications of the blade or impeller geometry. This paper describes an approach to the physical interpretation of the tip clearance flow in turbomachinery. First, typical flow phenomena of the tip clearance flow are outlined for axial and radial compressors, pumps and turbines to help comprehensive understanding of the tip clearance flow. Then, a vortex-core identification method which enables to extract the vortical structure from the complicated flow field is introduced, since elucidation of the vortical structure is essential to the physical interpretation of the tip clearance flow. By use of the vortex-core identification, some interesting phenomena of the tip clearance flows are interpreted, especially focussing on axial flow compressors.


Author(s):  
B. Stephan ◽  
H. E. Gallus ◽  
R. Niehuis

A multistage turbomachine has inherently unsteady flow fields due to the relative motion between rotor and stator airfoils, which lead to viscous and inviscid interactions between the blade rows. Additionally, the radial clearance between casing and rotor strongly influences the 3D flow field and the loss generation in turbomachines. The objective of the presented study is to investigate the effects of tip clearance on secondary flow phenomena and, in consequence, on the performance of a 1-1/2 stage axial turbine. The low aspect ratio of the blades and their prismatic design leads to a high degree of secondary flows and three-dimensionality. Extended measurements of the flow field behind each blade row with pneumatic and hotwire probes have been conducted for three different tip clearances. Experimental results reveal significant change of flow behavior and turbine performance with increasing tip clearance.


2016 ◽  
Vol 139 (1) ◽  
Author(s):  
Daniel Möller ◽  
Maximilian Jüngst ◽  
Felix Holzinger ◽  
Christoph Brandstetter ◽  
Heinz-Peter Schiffer ◽  
...  

This paper presents a numerical study on blade vibration for the transonic compressor rig at the Technische Universität Darmstadt (TUD), Darmstadt, Germany. The vibration was experimentally observed for the second eigenmode of the rotor blades at nonsynchronous frequencies and is simulated for two rotational speeds using a time-linearized approach. The numerical simulation results are in close agreement with the experiment in both cases. The vibration phenomenon shows similarities to flutter. Numerical simulations and comparison with the experimental observations showed that vibrations occur near the compressor stability limit due to interaction of the blade movement with a pressure fluctuation pattern originating from the tip clearance flow. The tip clearance flow pattern travels in the backward direction, seen from the rotating frame of reference, and causes a forward traveling structural vibration pattern with the same phase difference between blades. When decreasing the rotor tip gap size, the mechanism causing the vibration is alleviated.


Sign in / Sign up