Performance of Dehumidifying Heat Exchangers With and Without Wetting Coatings

1999 ◽  
Vol 121 (4) ◽  
pp. 1018-1026 ◽  
Author(s):  
K. Hong ◽  
R. L. Webb

Limited previous work has shown that use of special hydrophilic coatings will provide lower air pressure drop in finned tube heat exchangers operated under dehumidifying conditions. However, no detailed work has been reported on the effect of different coating types, or different fin surface geometries on the wet pressure drop. In this study, wind tunnel tests were performed on three different fin geometries (wavy, lanced, and louver) under wet and dry conditions. All dehumidification tests were done for fully wet surface conditions. For each geometry, the tests were performed on uncoated and coated heat exchangers. For all three fin geometries, the wet-to-dry pressure drop ratio was 1.2 at 2.5 m/s frontal air velocity. The coatings have no influence on the wet or dry heat transfer coefficient. However, the wet surface heat transfer coefficient was 10 to 30 percent less than the dry heat transfer coefficient, depending on the particular fin geometry. The effect of the fin press oil on wet pressure drop was also studied. If the oil contains a surfactant, good temporary wetting can be obtained on an uncoated surface; however, this effect is quickly degraded as the oil is washed from the surface during wet operation. This work also provides a critical assessment of data reduction methods for wet surface operation, including calculation of the fin efficiency.

2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2428 ◽  
Author(s):  
Charalampos Alexopoulos ◽  
Osama Aljolani ◽  
Florian Heberle ◽  
Tryfon C. Roumpedakis ◽  
Dieter Brüggemann ◽  
...  

Towards the introduction of environmentally friendlier refrigerants, CO2 cycles have gained significant attention in cooling and air conditioning systems in recent years. In this context, a design procedure for an air finned-tube CO2 gas cooler is developed. The analysis aims to evaluate the gas cooler design incorporated into a CO2 air conditioning system for residential applications. Therefore, a simulation model of the gas cooler is developed and validated experimentally by comparing its overall heat transfer coefficient. Based on the model, the evaluation of different numbers of rows, lengths, and diameters of tubes, as well as different ambient temperatures, are conducted, identifying the most suitable design in terms of pressure losses and required heat exchange area for selected operational conditions. The comparison between the model and the experimental results showed a satisfactory convergence for fan frequencies from 50 to 80 Hz. The absolute average deviations of the overall heat transfer coefficient for fan frequencies from 60 to 80 Hz were approximately 10%. With respect to the gas cooler design, a compromise between the bundle area and the refrigerant pressure drop was necessary, resulting in a 2.11 m2 bundle area and 0.23 bar refrigerant pressure drop. In addition, the analysis of the gas cooler’s performance in different ambient temperatures showed that the defined heat exchanger operates properly, compared to other potential gas cooler designs.


Author(s):  
Yaping Chen ◽  
Ruibing Cao ◽  
Jiafeng Wu ◽  
Cong Dong ◽  
Yanjun Sheng

A set of experiments were conducted on the circumferential overlap trisection helical baffle heat exchangers with inclined angles of 20°, 24°, 28° and 32° single-thread and inclined angle of 32° dual-thread one, and a segmental baffle heat exchanger as a contrast scheme. The cylinder case of the testing heat exchanger is a common shell, while the tube bundle core could be replaced. The shell side heat transfer coefficient ho is obtained by subtract tube-side convection thermal resistance and tube wall conduction resistance from the overall heat transfer coefficient K. The curves of shell side heat transfer coefficient ho, pressure drop Δpo, Nusselt number Nuo, and axial Euler number Euz,o are presented versus axial Reynolds number Rez,o. A comprehensive performance index Nuo/Euz,o is suggested to demonstrate the integral properties of both heat transfer and flow resistance of different schemes, and the curves of Nuo/Euz,o versus Rez,o of the different schemes are presented. The results show that the scheme with inclined angle 20° performs better than other schemes, and the scheme with inclined angle 24° ranks the second, however the segment scheme ranks the last. The curves of Nuo/Euz,o of both schemes with inclined angle 32° of single-thread and dual-thread are almost coincident, even though their heat transfer coefficient and pressure drop curves are quite different. The results indicate also that for the circumferential overlap trisection helical baffle schemes the optimal inclined angle is around 20° instead of around 40° as rated by many literatures for the quadrant helical baffle schemes.


Processes ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 754
Author(s):  
Muhammad Ammar Ali ◽  
Muhammad Sajid ◽  
Emad Uddin ◽  
Niaz Bahadur ◽  
Zaib Ali

In this study, the pressure drop and heat transfer characteristics of smooth tube and internal helically micro-finned tubes with two different fin-to-fin height ratios i.e., equal fin height and alternating fin height, are computationally analysed. The tube with alternating fin height is analysed for proof of concept of pressure drop reduction. A single phase steady turbulent flow model is used with a Reynolds number ranging from 12,000 to 54,000. Water is used as working fluid with inlet temperature of 55 °C and constant wall temperature of 20 °C is applied. Friction factor, heat transfer coefficient, Nusselt number, and Thermal Performance Index are evaluated and analysed. The numerical results are validated by comparison with the experimental and numerical data from literature. The results showed that the thermal performance is enhanced due to helically finned tube for a range of Reynolds numbers, but at the expense of increased pressure drop as compared to a smooth tube. The helically finned tube with alternating fin heights showed a 5% decrease in friction factor and <1% decrease in heat transfer coefficient when compared with the equal fin heights tube, making it a suitable choice for heat transfer applications.


Author(s):  
Arslan Saleem ◽  
Man-Hoe Kim

The air side thermal hydraulic performance of multi-louvered aluminium fin heat exchangers is investigated. A detailed study was performed to analyse the thermal performance of air over a wide range of Reynolds number i.e. from 30 to 250. Air-side heat transfer coefficient and air pressure drop were calculated and validated over the mentioned band of Reynolds numbers. Critical Reynolds number was determined numerically and the variation in flow physics along with the thermal and hydraulic performance of microchannel heat exchanger associated with R_cri has been reported. Moreover, a parametric study of the multi-louvered aluminium fin heat exchangers was also performed for 36 heat exchanger configurations with the louver angles (19-31&deg;), fin pitches (1.0, 1.2, 1.4 mm) and flow depths (16, 20, 24 mm); and the geometric configuration exhibiting the highest thermal performance was reported. The air-side heat transfer coefficient and pressure drop results for different geometrical configurations were presented in terms of Colburn j factor and Fanning friction factor f, as a function of Reynolds number based on louver pitch.