scholarly journals Discussion: “On the Presentation of Performance Data for Enhanced Tubes Used in Shell-and-Tube Heat Exchangers” (Marner, W. J., Bergles, A. E., and Chenoweth, J. M., 1983, ASME J. Heat Transfer, 105, pp. 358–364)

1984 ◽  
Vol 106 (4) ◽  
pp. 908-909
Author(s):  
H. Soumerai
1983 ◽  
Vol 105 (2) ◽  
pp. 358-365 ◽  
Author(s):  
W. J. Marner ◽  
A. E. Bergles ◽  
J. M. Chenoweth

As the efforts to produce more efficient heat transfer equipment continue, an increasing number of augmented surfaces are being produced commercially. Consequently, the designer faces an almost overwhelming task in comparing and evaluating the performance of various surfaces because of the many different ways in which the test data are currently presented in the literature. Thus, a uniform format for presenting pressure drop and heat transfer data for enhanced surfaces has become a necessity. This paper is concerned with one important aspect of this problem, namely, that of tubular enhanced surfaces used in shell-and-tube heat exchangers. As an initial step, the subject is limited to single-phase pressure drop and heat transfer; however, both tubeside and shellside flow are taken into consideration. A comprehensive list of commerical augmented tubes which may be considered for use in shell-and-tube exchangers is given, along with a survey of the performance data which are available in the literature. A standardized data format which uses the inside and outside envelope diameters as the basis for presenting the various geometrical, flow, and heat transfer parameters for all tubular enhanced surfaces is proposed and discussed.


2009 ◽  
Vol 62-64 ◽  
pp. 694-699 ◽  
Author(s):  
E. Akpabio ◽  
I.O. Oboh ◽  
E.O. Aluyor

Shell and tube heat exchangers in their various construction modifications are probably the most widespread and commonly used basic heat exchanger configuration in the process industries. There are many modifications of the basic configuration which can be used to solve special problems. Baffles serve two functions: Most importantly, they support the tubes in the proper position during assembly and operation and prevent vibration of the tubes caused by flow-induced eddies, and secondly, they guide the shell-side flow back and forth across the tube field, increasing the velocity and the heat transfer coefficient. The objective of this paper is to find the baffle spacing at fixed baffle cut that will give us the optimal values for the overall heat transfer coefficient. To do this Microsoft Excel 2003 package was employed. The results obtained from previous studies showed that to obtain optimal values for the overall heat transfer coefficient for the shell and tube heat exchangers a baffle cut of 20 to 25 percent of the diameter is common and the maximum spacing depends on how much support the tubes need. This was used to validate the results obtained from this study.


1988 ◽  
Vol 110 (1) ◽  
pp. 54-59 ◽  
Author(s):  
A. Pignotti ◽  
P. I. Tamborenea

The thermal effectiveness of a TEMA E shell-and-tube heat exchanger, with one shell pass and an arbitrary number of tube passes, is determined under the usual symplifying assumptions of perfect transverse mixing of the shell fluid, no phase change, and temperature independence of the heat capacity rates and the heat transfer coefficient. A purely algebraic solution is obtained for the effectiveness as a function of the heat capacity rate ratio and the number of heat transfer units. The case with M shell passes and N tube passes is easily expressed in terms of the single-shell-pass case.


Author(s):  
Ahmet Selim Dalkiliç ◽  
Ali Celen ◽  
Mohamed M. Awad ◽  
Somchai Wongwises

Heat exchangers using in-tube condensation have great significance in the refrigeration, automotive and process industries. Effective heat exchangers have been rapidly developed due to the demand for more compact systems, higher energy efficiency, lower material costs and other economic incentives. Enhanced surfaces, displaced enhancement devices, swirl-flow devices and surface tension devices improve the heat transfer coefficients in these heat exchangers. This study is a critical review on the determination of the condensation heat transfer coefficient of pure refrigerants flowing in vertical and horizontal tubes. The authors’ previous publications on this issue, including the experimental, theoretical and numerical analyses are summarized here. The lengths of the vertical and horizontal test sections varied between 0.5 m and 4 m countercurrent flow double-tube heat exchangers with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The measured data are compared to theoretical and numerical predictions based on the solution of the artificial intelligence methods and CFD analyses for the condensation process in the smooth and enhanced tubes. The theoretical solutions are related to the design of double tube heat exchangers in refrigeration, air conditioning and heat pump applications. Detailed information on the in-tube condensation studies of heat transfer coefficient in the literature is given. A genetic algorithm (GA), various artificial neural network models (ANN) such as multilayer perceptron (MLP), radial basis networks (RBFN), generalized regression neural network (GRNN), and adaptive neuro-fuzzy inference system (ANFIS), and various optimization techniques such as unconstrained nonlinear minimization algorithm-Nelder-Mead method (NM), non-linear least squares error method (NLS), and Ansys CFD program are used in the numerical solutions. It is shown that the convective heat transfer coefficient of laminar and turbulent condensing film flows can be predicted by means of theoretical and numerical analyses reasonably well if there is a sufficient amount of reliable experimental data. Regression analysis gave convincing correlations, and the most suitable coefficients of the proposed correlations are depicted as compatible with the large number of experimental data by means of the computational numerical methods.


Author(s):  
Yacine Khetib ◽  
Hala M. Abo-Dief ◽  
Abdullah K. Alanazi ◽  
S. Mohammad Sajadi ◽  
Suvanjan Bhattacharyya ◽  
...  

1982 ◽  
Vol 104 (3) ◽  
pp. 257-261
Author(s):  
T. M. Kuzay ◽  
C. B. Panchal ◽  
A. P. Gavin

Heat-transfer monitors (HTMs) have been used since 1976 to measure the reduction in the seawater heat-transfer coefficient due to buildup of biofouling and corrosion products inside circular tubes of shell-and-tube heat exchangers being developed for ocean thermal energy conversion (OTEC) plants. For OTEC heat exchangers (HXs) with other tube geometries, special, modified HTMs, which we call STMs, are being sought. The analytical approaches and calibration results to date are summarized for STMs of two types: (i) an STM simulating a rectangular seawater passage in a compact, aluminum, plate-fin HX, and (ii) an STM for a helical stainless-steel tube. The development of type 1 has been successful. A software change is needed for type 2.


2021 ◽  
Author(s):  
praveen math

Abstract Shell and Tube heat exchangers are having special importance in boilers, oil coolers, condensers, pre-heaters. They are also widely used in process applications as well as the refrigeration and air conditioning industry. The robustness and medium weighted shape of Shell and Tube heat exchangers make them well suited for high pressure operations. The aim of this study is to experiment, validate and to provide design suggestion to optimize the shell and tube heat exchanger (STHE). The heat exchanger is made of acrylic material with 2 baffles and 7 tubes made of stainless steel. Hot fluid flows inside the tube and cold fluid flows over the tube in the shell. 4 K-type thermocouples were used to read the hot and cold fluids inlet and outlet temperatures. Experiments were carried out for various combinations of hot and cold water flow rates with different hot water inlet temperatures. The flow conditions are limited to the lab size model of the experimental setup. A commercial CFD code was used to study the thermal and hydraulic flow field inside the shell and tubes. CFD methodology is developed to appropriately represent the flow physics and the procedure is validated with the experimental results. Turbulent flow in tube side is observed for all flow conditions, while the shell side has laminar flow except for extreme hot water temperatures. Hence transition k-kl-omega model was used to predict the flow better for transition cases. Realizable k- epsilon model with non-equilibrium wall function was used for turbulent cases. Temperature and velocity profiles are examined in detail and observed that the flow remains almost uniform to the tubes thus limiting heat transfer. Approximately 2/3 rd of the shell side flow does not surround the tubes due to biased flow contributing to reduced overall heat transfer and increased pressure loss. On the basis of these findings an attempt has been made to enhance the heat transfer by inducing turbulence in the shel l side flow. The two baffles were rotated in opposite direction to each other to achieve more circulation in the shell side flow and provide more contact with tube surface. Various positions of the baffles were simulated and studied using CFD analysis and th e results are summarized with respect to heat transfer and pressure loss.


Sign in / Sign up

Export Citation Format

Share Document