Framework for a Unified Model for Nucleate and Transition Pool Boiling

1989 ◽  
Vol 111 (3) ◽  
pp. 739-746 ◽  
Author(s):  
V. K. Dhir ◽  
S. P. Liaw

An area and time-averaged model for saturated pool boiling heat fluxes has been developed. In the model, which is valid in the upper end of nucleate boiling and in transition boiling, the existence of stationary vapor stems at the wall is assumed. The energy from the wall is conducted into the liquid macro/micro thermal layer surrounding the stems and is utilized in evaporation at the stationary liquid–vapor interface. The heat transfer rate into the thermal layer and the temperature distribution in it are determined by solving a two-dimensional steady-state conduction equation. The evaporation rate is given by the kinetic theory. The heater surface area over which the vapor stems exist is taken to be dry. Employing experimentally observed void fractions, not only the nucleate and transition boiling heat fluxes but also the maximum and minimum heat fluxes are predicted from the model. The maximum heat fluxes obtained from the model are valid only for surfaces that are not well wetted and includes the contact angle as one of the parameters.

1969 ◽  
Vol 91 (3) ◽  
pp. 315-328 ◽  
Author(s):  
I. Shai ◽  
W. M. Rohsenow

Experimental data for sodium boiling on horizontal surfaces containing artificial cavities at heat fluxes of 20,000 to 300,000 Btu/ft2 hr and pressures between 40 to 106 mm Hg were obtained. Observations are made for stable boiling, unstable boiling and “bumping.” Some recorded temperature variations in the solid close to the nucleating cavity are presented. It is suggested that for liquid metals the time for bubble growth and departure is a very small fraction of the total bubble cycle, hence the delay time during which a thermal layer grows is the most significant part of the process. On this basis the transient conduction heat transfer is solved for a periodic process, and the period time is found to be a function of the degree of superheat, the heat flux and the liquid thermal properties. A simplified model for stability of nucleate pool boiling of liquid metals is postulated from which the minimum heat flux for stable boiling can be found as a function of liquid-solid properties, liquid pressure, the degree of superheat, and the cavity radius and depth. At relatively low heat fluxes, convection currents have significant effects on the period time of bubble formation. An empirical correlation is proposed, which takes into account the convection effects, to match the experimental results.


1995 ◽  
Vol 117 (2) ◽  
pp. 408-417 ◽  
Author(s):  
T. Oka ◽  
Y. Abe ◽  
Y. H. Mori ◽  
A. Nagashima

A series of pool boiling experiments have been conducted under reduced gravity condition (the order of 10−2 times the terrestrial gravity) available in an aircraft taking parabolic flight. A transparent resistant heater, a transparent indium oxide film plated on a glass plate, was employed so that the vapor/liquid behavior interacting with the heater surface could be observed from the rear side of the heater simultaneously with the side view of vapor bubbles above the heater surface. The experiments were performed for three different fluids—n-pentane, CFC-113, and water—under subcooled conditions. The critical heat fluxes for both n-pentane and CFC-113 under the reduced gravity were lowered to about 40 percent of the corresponding terrestrial values. Although the heat transfer characteristics in a low heat flux nucleate boiling regime for both n-pentane and CFC-113 showed no more than a slight change with the reduction in gravity, a significant heat transfer deterioration was noted with water in the reduced gravity boiling. The observation from the rear side of the heater suggested that this particular difference in the gravity dependency of heat transfer was ascribed to a considerable difference, between the organic fluids and water, in the behavior of attachment to the heater surface of the bubbles grown up, while the behavior of attachment must depend on the surface tension of each fluid and the wettability of the heater surface with the fluid.


Author(s):  
Akshat Negi ◽  
Aniket M. Rishi ◽  
Satish G. Kandlikar

Abstract Boiling heat transfer is extensively used in various industrial applications to efficiently dissipate a large amount of heat by maintaining lower surface temperatures. The maximum heat flux dissipated during boiling is limited by the critical heat flux (CHF) and limited visualization of the boiling surface limits the identification of the impending CHF condition to rely on temperature monitoring alone. The study presented here focuses on developing a method for analyzing and identifying acoustic signatures throughout the nucleate boiling regimes that are indicative of the boiling state of the heater surface. The bubble nucleation and coalescence along with bubble collapse at the liquid-vapor interface leads to variation in acoustic emission patterns during boiling. These sound waves are studied and acoustic signatures that are representative of the impending CHF are identified over plain and enhanced copper substrates with water as the working fluid. During pool boiling study, it was observed that sound was dominant in two frequency regions (400–500 Hz dominant throughout nucleate boiling and 100–200 Hz dominant at heat fluxes > 100 W/cm2). However, just before CHF, a sudden drop in amplitude was observed in the high frequency region (400–500 Hz), while the amplitude in low frequency region (100–200 Hz) continued to rise. It was concluded that this acoustic study can be used as a tool to predict the approaching CHF condition.


2021 ◽  
Vol 143 (5) ◽  
Author(s):  
Akshat Negi ◽  
Aniket M. Rishi ◽  
Satish G. Kandlikar

Abstract Boiling heat transfer is extensively used in various industrial applications to efficiently dissipate a large amount of heat by maintaining low surface to fluid temperature differences. The maximum heat flux dissipated during boiling is limited by the critical heat flux (CHF). Difficulties in visualizing the boiling process and monitoring surface temperature make it difficult to identify the impending CHF condition. As a result, larger factors of safety are employed, and the equipment is operated at considerably lower heat fluxes. This study focuses on identifying acoustic signatures of different nucleate boiling regimes. The bubble nucleation and coalescence along with bubble collapse lead to variation in acoustic emission patterns during boiling. In this work, acoustic signatures representative of the impending CHF condition are identified during pool boiling of water over plain and enhanced copper substrates. It was observed that sound was dominant in two frequency regions (400–500 Hz dominant throughout the nucleate boiling, and 100–200 Hz dominant at heat fluxes > 100 W/cm2). However, just before CHF, a sudden drop in amplitude was observed in the high frequency region (400–500 Hz), while the amplitude in low frequency region (100–200 Hz) continued to rise. This combination of the amplitude trend has potential to predict the approaching CHF condition. This is the first study that correlates high-speed images with the acoustic trends at different stages of nucleate boiling and compares experimental frequency with Minnaert frequency for coalescing bubbles.


1966 ◽  
Vol 88 (1) ◽  
pp. 94-99 ◽  
Author(s):  
John H. Lienhard ◽  
Kiyokazu Watanabe

The peak nucleate boiling heat flux has been observed for five fluids during saturated pool boiling on horizontal wire heaters, ranging in radius from 0.0025 in. to 0.0254 in., over a reduced pressure range from 0.0010 to 0.0197. A scheme for correlating the peak and minimum heat fluxes is developed heuristically and successfully applied to these data. The result is a single three-dimensional surface which represents all of the data. The surface can be represented as the product of a function of geometric scale, and a function of pressure. The function of pressure appears to be the same in any configuration.


2011 ◽  
Vol 133 (11) ◽  
Author(s):  
K. Hari Krishna ◽  
Harish Ganapathy ◽  
G. Sateesh ◽  
Sarit K. Das

Nanofluids, solid-liquid suspensions with solid particles of size of the order of few nanometers, have created interest in many researchers because of their enhancement in thermal conductivity and convective heat transfer characteristics. Many studies have been done on the pool boiling characteristics of nanofluids, most of which have been with nanofluids containing oxide nanoparticles owing to the ease in their preparation. Deterioration in boiling heat transfer was observed in some studies. Metallic nanofluids having metal nanoparticles, which are known for their good heat transfer characteristics in bulk regime, reported drastic enhancement in thermal conductivity. The present paper investigates into the pool boiling characteristics of metallic nanofluids, in particular of Cu-H2O nanofluids, on flat copper heater surface. The results indicate that at comparatively low heat fluxes, there is deterioration in boiling heat transfer with very low particle volume fraction of 0.01%, and it increases with volume fraction and shows enhancement with 0.1%. However, the behavior is the other way around at high heat fluxes. The enhancement at low heat fluxes is due to the fact that the effect of formation of thin sorption layer of nanoparticles on heater surface, which causes deterioration by trapping the nucleation sites, is overshadowed by the increase in microlayer evaporation, which is due to enhancement in thermal conductivity. Same trend has been observed with variation in the surface roughness of the heater as well.


2006 ◽  
Vol 128 (12) ◽  
pp. 1302-1311 ◽  
Author(s):  
Camil-Daniel Ghiu ◽  
Yogendra K. Joshi

An experimental study of pool boiling using enhanced structures under top-confined conditions was conducted with a dielectric fluorocarbon liquid (PF 5060). The single layer enhanced structures studied were fabricated in copper and quartz, had an overall size of 10×10mm2, and were 1mm thick. The parameters investigated in this study were the heat flux (0.8-34W∕cm2) and the top space S(0-13mm). High-speed visualizations were performed to elucidate the liquid/vapor flow in the space above the structure. The enhancement observed for plain surfaces in the low heat fluxes regime is not present for the present enhanced structure. On the other hand, the maximum heat flux for a prescribed 85°C surface temperature limit increased with the increase of the top spacing, similar to the plain surfaces case. Two characteristic regimes of pool boiling have been identified and described: isolated flattened bubbles regime and coalesced bubbles regime.


Sign in / Sign up

Export Citation Format

Share Document