Effect of Freestream Turbulence Intensity on Film Cooling Jet Structure and Surface Effectiveness Using PIV and PSP

2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

An experimental investigation of film cooling jet structure using two-dimensional particle image velocimetry (PIV) has been completed for cylindrical, simple angle (θ=35 deg) film cooling holes. The PIV measurements are coupled with detailed film cooling effectiveness distributions on the flat plate obtained using a steady state, pressure sensitive paint (PSP) technique. Both the flow and surface measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied from 1.2% to 12.5%. With this traditional film cooling configuration, the blowing ratio was varied from 0.5 to 1.5 to compare the jet structure of relatively low and high momentum cooling flows. Velocity maps of the coolant flow (in the streamwise direction) are obtained on three planes spanning a single hole: centerline, 0.25D, and 0.5D (outer edge of the film cooling hole). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets are obtained near the cooled surface. In addition, turbulent fluctuations are obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV (both instantaneous and time averaged) with detailed film cooling effectiveness distributions on the surface (PSP) provides a more complete view of the coolant jet-mainstream flow interaction. Near the edge of the film cooling holes, the turbulent mixing increases, and as a result the film cooling effectiveness decreases. Furthermore, the PIV measurements show the increased mixing of the coolant jet with the mainstream at the elevated freestream turbulence level resulting in a reduction in the jet to effectively protect the film cooled surface.

Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

An experimental investigation of film cooling jet structure using two-dimensional, particle image velocimetry (PIV) has been completed for cylindrical, simple angle (θ = 35°) film cooling holes. The PIV measurements are coupled with detailed film cooling effectiveness distributions on the flat plate obtained using a steady state, pressure sensitive paint (PSP) technique. Both the flow and surface measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied from 1.2% to 12.5%. With this traditional film cooling configuration, the blowing ratio was varied from 0.5–1.5 to compare the jet structure of relatively low and high momentum cooling flows. Velocity maps of the coolant flow (in the streamwise direction) are obtained on three planes spanning a single hole: centerline, 0.25D, and 0.5D (outer edge of the film cooling hole). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets are obtained near the cooled surface. In addition, turbulent fluctuations are obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV (both instantaneous and time averaged) with detailed film cooling effectiveness distributions on the surface (PSP), provides a more complete view of the coolant jet–mainstream flow interaction. Near the edge of the film cooling holes, the turbulent mixing increases, and as a result the film cooling effectiveness decreases. Furthermore, the PIV measurements show the increased mixing of the coolant jet with the mainstream at the elevated freestream turbulence level resulting in a reduction of the jet to effectively protect the film cooled surface.


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

The coolant jet structure of fanshaped film cooling holes is experimentally investigated using two-dimensional particle image velocimetry (PIV). These results are coupled with detailed film cooling effectiveness distributions to directly relate the jet structure to surface phenomena. The cooling performance of simple angle, fanshaped holes (θ = 35°, α = 10°) is considered. The results from these shaped holes are compared to those from a traditional simple angle, cylindrical hole (θ = 35°). The flow measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied up to 12.5%. The blowing ratio was varied from 0.5–1.5 to compare the jet structure of relatively low and high momentum cooling flows. Time averaged velocity maps of the coolant flow (in the streamwise direction) were obtained on three planes spanning a single hole: the centerline of the hole, the edge of the cylindrical section of the hole (0.5D), and the edge of the shaped portion of the hole (0.94D). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets were obtained near the cooled surface. In addition, turbulent fluctuations were obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV with detailed film cooling effectiveness distributions on the surface (PSP), provides a more complete view of the coolant jet – mainstream flow interaction. Due to the reduced momentum of the coolant, the shaped holes provide improved protection of the flat plate compared to the cylindrical holes. With the reduced velocity of the coolant from the shaped holes, additional turbulent mixing between the freestream and the coolant occurs. However, the increased turbulence does not induce significant changes to the jet structure nor to the surface protection offered by the coolant. Furthermore, the robustness of the fanshaped design is demonstrated through the presentation of time averaged turbulence quantities across the span of the cooling jet.


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

Detailed film cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The applicability of the PSP technique is expanded to include a coolant-to-mainstream density ratio of 1.4. The effect of density ratio on the film cooling effectiveness is coupled with varying blowing ratio (M = 0.25–2.0), freestream turbulence intensity (Tu = 1%–12.5%), and film hole geometry. The effectiveness distributions are obtained on three separate flat plates containing either simple angle, cylindrical holes, simple angle, fanshaped holes (α = 10°), or simple angle, laidback, fanshaped holes (α = 10°, γ = 10°). In all three cases, the film cooling holes are angled at θ = 35° from the mainstream flow. Using the PSP technique, the combined effects of blowing ratio, turbulence intensity, and density ratio are captured for each film cooling geometry. The detailed film cooling effectiveness distributions, for cylindrical holes, clearly show the effectiveness at the lowest blowing ratio is enhanced at the lower density ratio (DR = 1). However, as the blowing ratio increases, a transition occurs, leading to increased effectiveness with the elevated density ratio (DR = 1.4). In addition, the PSP technique captures an upstream shift of the coolant jet reattachment point as the density ratio increases or the turbulence intensity increases (at moderate blowing ratios for cylindrical holes). With the decreased momentum of the shaped film cooling holes, the greatest film cooling effectiveness is obtained at the lower density ratio (DR = 1.0) over the entire range of blowing ratios considered. In all cases, as the freestream turbulence intensity increases, the film effectiveness decreases; this effect is reduced as the blowing ratio increases for all three film hole configurations.


2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

Detailed film-cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The applicability of the PSP technique is expanded to include a coolant-to-mainstream density ratio of 1.4. The effect of density ratio on the film-cooling effectiveness is coupled with varying blowing ratio (M=0.25–2.0), freestream turbulence intensity (Tu=1–12.5%), and film hole geometry. The effectiveness distributions are obtained on three separate flat plates containing either simple angle, cylindrical holes, simple angle, fanshaped holes (α=10 deg), or simple angle, laidback, fanshaped holes (α=10 deg and γ=10 deg). In all three cases, the film-cooling holes are angled at θ=35 deg from the mainstream flow. Using the PSP technique, the combined effects of blowing ratio, turbulence intensity, and density ratio are captured for each film-cooling geometry. The detailed film-cooling effectiveness distributions, for cylindrical holes, clearly show that the effectiveness at the lowest blowing ratio is enhanced at the lower density ratio (DR=1). However, as the blowing ratio increases, a transition occurs, leading to increased effectiveness with the elevated density ratio (DR=1.4). In addition, the PSP technique captures an upstream shift of the coolant jet reattachment point as the density ratio increases or the turbulence intensity increases (at moderate blowing ratios for cylindrical holes). With the decreased momentum of the shaped film-cooling holes, the greatest film-cooling effectiveness is obtained at the lower density ratio (DR=1.0) over the entire range of blowing ratios considered. In all cases, as the freestream turbulence intensity increases, the film effectiveness decreases; this effect is reduced as the blowing ratio increases for all three film hole configurations.


Author(s):  
Timothy W. Repko ◽  
Andrew C. Nix ◽  
James D. Heidmann

An advanced, high-effectiveness film-cooling design, the anti-vortex hole (AVH) has been investigated by several research groups and shown to mitigate or counter the vorticity generated by conventional holes and increase film effectiveness at high blowing ratios and low freestream turbulence levels. [1, 2] The effects of increased turbulence on the AVH geometry were previously investigated and presented by researchers at West Virginia University (WVU), in collaboration with NASA, in a preliminary CFD study [3] on the film effectiveness and net heat flux reduction (NHFR) at high blowing ratio and elevated freestream turbulence levels for the adjacent AVH. The current paper presents the results of an extended numerical parametric study, which attempts to separate the effects of turbulence intensity and length-scale on film cooling effectiveness of the AVH. In the extended study, higher freestream turbulence intensity and larger scale cases were investigated with turbulence intensities of 5, 10 and 20% and length scales based on cooling hole diameter of Λx/dm = 1, 3 and 6. Increasing turbulence intensity was shown to increase the centerline, span-averaged and area-averaged adiabatic film cooling effectiveness. Larger turbulent length scales were shown to have little to no effect on the centerline, span-averaged and area-averaged adiabatic film-cooling effectiveness at lower turbulence levels, but slightly increased effect at the highest turbulence levels investigated.


Author(s):  
Lucas Giller ◽  
Heinz-Peter Schiffer

The interaction between the strongly swirling combustor outflow and the high pressure turbine nozzle guide vanes were investigated at the cascade test rig at Technische Universität Darmstadt. The test section of the rig consists of six swirl generators and five cascade vanes. The three middle vanes are equipped with film cooling holes at the leading edges. The swirler nozzles are aligned with the center of the cascade passages. The operating settings are defined by the swirl number, the distance between the swirler nozzles and the vanes, the blowing ratio and the radial angle of the film cooling holes. Flow field measurements using PIV downstream of the swirlers and five hole probe measurements at the inlet and outlet plane of the cascade were accomplished. Measurements using the ammonia diazo technique to determine the adiabatic film cooling effectiveness on the surface of the center cascade vane were also carried out. It is shown that a swirling inflow leads to a strong alteration of the flow field and the losses in the passages in comparison to an axial inflow. Furthermore, the impact of the swirl on the formation of the cooling film and it’s adiabatic film cooling effectiveness is presented.


2015 ◽  
Vol 138 (4) ◽  
Author(s):  
Emin Issakhanian ◽  
Christopher J. Elkins ◽  
John K. Eaton

The need for improvements in film cooling effectiveness over traditional cylindrical film cooling holes has led to varied shaped hole and sister hole designs of increasing complexity. This paper presents a simpler shaped hole design which shows improved film cooling effectiveness over both cylindrical holes and diffusing fan-shaped holes without the geometric complexity of the latter. Magnetic resonance imaging measurement techniques are used to reveal the coupled 3D velocity and coolant mixing from film cooling holes which are of a constant oval cross section as opposed to round. The oval-shaped hole yielded an area-averaged adiabatic effectiveness twice that of the diffusing fan-shaped hole tested. Three component mean velocity measurements within the channel and cooling hole showed the flow features and vorticity fields which explain the improved performance of the oval-shaped hole. As compared to the round hole, the oval hole leads to a more complex vorticity field, which reduces the strength of the main counter-rotating vortex pair (CVP). The CVP acts to lift the coolant away from the turbine blade surface, and thus strongly reduces the film cooling effectiveness. The weaker vortices allow the coolant to stay closer to the blade surface and to remain relatively unmixed with the main flow over a longer distance. Thus, the oval-shaped film cooling hole provides a simpler solution for improving film cooling effectiveness beyond circular hole and diffusing hole designs.


Author(s):  
W. Colban ◽  
K. A. Thole ◽  
M. Haendler

Fan-shaped film-cooling holes have been shown to provide superior cooling performance to cylindrical holes along flat-plates and turbine airfoils over a large range of different conditions. Benefits of fan-shaped holes include less required cooling air for the same performance, increased part lifetime, and fewer required holes. The major drawback however, is increased manufacturing cost and manufacturing difficulty, particularly for the vane platform region. To this point, there have only been extremely limited comparisons between cylindrical and shaped holes on a turbine endwall at either low or high freestream turbulence conditions. This study presents film-cooling effectiveness measurements on an endwall surface in a large-scale, low-speed, two-passage, linear vane cascade. Results showed that film-cooling effectiveness decreased with increasing blowing rate for the cylindrical holes, indicating jet lift-off. However, the fan-shaped passage showed increased film-cooling effectiveness with increasing blowing ratio. Overall, fan-shaped holes increased film-cooling effectiveness by an average of 75% over cylindrical holes for constant cooling flow.


2008 ◽  
Vol 130 (3) ◽  
Author(s):  
W. Colban ◽  
K. A. Thole ◽  
M. Haendler

Fan-shaped film-cooling holes have been shown to provide superior cooling performance to cylindrical holes along flat plates and turbine airfoils over a large range of different conditions. Benefits of fan-shaped holes include less required cooling air for the same performance, increased part lifetime, and fewer required holes. The major drawback, however, is increased manufacturing cost and manufacturing difficulty, particularly for the vane platform region. To this point, there have only been extremely limited comparisons between cylindrical and shaped holes on a turbine endwall at either low or high freestream turbulence conditions. This study presents film-cooling effectiveness measurements on an endwall surface in a large-scale, low-speed, two-passage, linear vane cascade. Results showed that film-cooling effectiveness decreased with increasing blowing rate for the cylindrical holes, indicating jet liftoff. However, the fan-shaped passage showed increased film-cooling effectiveness with increasing blowing ratio. Overall, fan-shaped holes increased film-cooling effectiveness by an average of 75% over cylindrical holes for constant cooling flow.


Author(s):  
Timothy W. Repko ◽  
Andrew C. Nix ◽  
Can Uysal ◽  
James D. Heidmann

An advanced, high-effectiveness film cooling design, the antivortex hole (AVH) has been investigated by several research groups and shown to mitigate or counter the vorticity generated by conventional holes and increase film effectiveness at high blowing ratios and low freestream turbulence levels. The effects of increased turbulence on an AVH geometry were previously investigated in a preliminary steady computational fluid dynamics (CFD) study by Hunley et al. on the film effectiveness and net heat flux reduction (NHFR) at high blowing ratio. The current paper presents the results of an extended numerical parametric study, which attempts to separate the effects of turbulence intensity and length scale on film cooling performance of the AVH concept at high blowing ratio (2.0) and density ratio (2.0). In this extended study, steady Reynolds-averaged Navier–Stokes (RANS) analysis was performed with turbulence intensities of 5, 10, and 20% and length scales based on cooling hole diameter of Λx/dm = 1, 3, and 6. Increasing turbulence intensity was shown to increase the centerline, span-averaged, and area-averaged adiabatic film cooling effectiveness and NHFR. Larger turbulent length scales in the steady RANS analysis were shown to have little to no effect on the centerline, span-averaged, and area-averaged adiabatic film cooling effectiveness and NHFR at lower turbulence levels, but moderate effect at the highest turbulence levels investigated. Heat transfer results were in good agreement with the findings from adiabatic cases from previous work. Unsteady RANS results also provided supplementary flow visualization for the AVH film cooling flow under varying turbulence levels.


Sign in / Sign up

Export Citation Format

Share Document