Film Cooling Effectiveness Improvements Using a Nondiffusing Oval Hole

2015 ◽  
Vol 138 (4) ◽  
Author(s):  
Emin Issakhanian ◽  
Christopher J. Elkins ◽  
John K. Eaton

The need for improvements in film cooling effectiveness over traditional cylindrical film cooling holes has led to varied shaped hole and sister hole designs of increasing complexity. This paper presents a simpler shaped hole design which shows improved film cooling effectiveness over both cylindrical holes and diffusing fan-shaped holes without the geometric complexity of the latter. Magnetic resonance imaging measurement techniques are used to reveal the coupled 3D velocity and coolant mixing from film cooling holes which are of a constant oval cross section as opposed to round. The oval-shaped hole yielded an area-averaged adiabatic effectiveness twice that of the diffusing fan-shaped hole tested. Three component mean velocity measurements within the channel and cooling hole showed the flow features and vorticity fields which explain the improved performance of the oval-shaped hole. As compared to the round hole, the oval hole leads to a more complex vorticity field, which reduces the strength of the main counter-rotating vortex pair (CVP). The CVP acts to lift the coolant away from the turbine blade surface, and thus strongly reduces the film cooling effectiveness. The weaker vortices allow the coolant to stay closer to the blade surface and to remain relatively unmixed with the main flow over a longer distance. Thus, the oval-shaped film cooling hole provides a simpler solution for improving film cooling effectiveness beyond circular hole and diffusing hole designs.

Author(s):  
Emin Issakhanian ◽  
Christopher J. Elkins ◽  
John K. Eaton

The need for improvements in film cooling effectiveness over traditional cylindrical film cooling holes has led to varied shaped hole and sister hole designs of increasing complexity. This paper presents a simpler shaped-hole design which shows improved film cooling effectiveness over both cylindrical holes and diffusing fan-shaped holes without the geometric complexity of the latter. Magnetic resonance imaging measurement techniques are used to reveal the coupled 3D velocity and coolant mixing from film cooling holes which are of a constant oval cross-section as opposed to round. The oval shaped hole yielded an area-averaged adiabatic effectiveness twice that of the diffusing fan-shaped hole tested. Three component mean velocity measurements within the channel and cooling hole showed the flow features and vorticity fields which explain the improved performance of the oval shaped hole. As compared to the round hole, the oval hole leads to a more complex vorticity field which reduces the strength of the main counter-rotating vortex pair. The counter-rotating vortex pair acts to lift the coolant away from the turbine blade surface and thus strongly reduces the film cooling effectiveness. The weaker vortices allow coolant to stay closer to the blade surface and to remain relatively unmixed with the main flow over a longer distance. Thus, the oval-shaped film cooling hole provides a simpler solution for improving film cooling effectiveness beyond circular hole and diffusing hole designs.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45 deg and 135 deg, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both prerib and postrib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Marc Fraas ◽  
Tobias Glasenapp ◽  
Achmed Schulz ◽  
Hans-Jörg Bauer

Internal coolant passages of gas turbine vanes and blades have various orientations relative to the external hot gas flow. As a consequence, the inflow of film cooling holes varies as well. To further identify the influencing parameters of film cooling under varying inflow conditions, the present paper provides detailed experimental data. The generic study is performed in a novel test rig, which enables compliance with all relevant similarity parameters including density ratio. Film cooling effectiveness as well as heat transfer of a 10–10–10 deg laidback fan-shaped cooling hole is discussed. Data are processed and presented over 50 hole diameters downstream of the cooling hole exit. First, the parallel coolant flow setup is discussed. Subsequently, it is compared to a perpendicular coolant flow setup at a moderate coolant channel Reynolds number. For the perpendicular coolant flow, asymmetric flow separation in the diffuser occurs and leads to a reduction of film cooling effectiveness. For a higher coolant channel Reynolds number and perpendicular coolant flow, asymmetry increases and cooling effectiveness is further decreased. An increase in blowing ratio does not lead to a significant increase in cooling effectiveness. For all cases investigated, heat transfer augmentation due to film cooling is observed. Heat transfer is highest in the near-hole region and decreases further downstream. Results prove that coolant flow orientation has a severe impact on both parameters.


2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

An experimental investigation of film cooling jet structure using two-dimensional particle image velocimetry (PIV) has been completed for cylindrical, simple angle (θ=35 deg) film cooling holes. The PIV measurements are coupled with detailed film cooling effectiveness distributions on the flat plate obtained using a steady state, pressure sensitive paint (PSP) technique. Both the flow and surface measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied from 1.2% to 12.5%. With this traditional film cooling configuration, the blowing ratio was varied from 0.5 to 1.5 to compare the jet structure of relatively low and high momentum cooling flows. Velocity maps of the coolant flow (in the streamwise direction) are obtained on three planes spanning a single hole: centerline, 0.25D, and 0.5D (outer edge of the film cooling hole). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets are obtained near the cooled surface. In addition, turbulent fluctuations are obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV (both instantaneous and time averaged) with detailed film cooling effectiveness distributions on the surface (PSP) provides a more complete view of the coolant jet-mainstream flow interaction. Near the edge of the film cooling holes, the turbulent mixing increases, and as a result the film cooling effectiveness decreases. Furthermore, the PIV measurements show the increased mixing of the coolant jet with the mainstream at the elevated freestream turbulence level resulting in a reduction in the jet to effectively protect the film cooled surface.


Author(s):  
K. Vighneswara Rao ◽  
Jong S. Liu ◽  
Daniel C. Crites ◽  
Luis A. Tapia ◽  
Malak F. Malak ◽  
...  

In this study, cylindrical and fan shaped film cooling holes are evaluated on the blade surface numerically, using the Computational Fluid Dynamics (CFD) tool ANSYS-CFX, with the objective of improving cooling effectiveness by understanding the flow pattern at the cooling hole exit. The coolant flow rates are adjusted for blowing ratios of 0.5, 1.0 & 1.5 (momentum flux ratios of 0.125, 0.5 & 1.125 respectively). The density ratio is maintained at 2.0. New shaped holes viz. straight, concave and convex trench holes are introduced and are evaluated under similar operating conditions. Results are presented in terms of surface temperatures and adiabatic effectiveness at three different blowing ratios for the different film cooling hole shapes analyzed. Comparison is made with reference to the fan shaped film cooling hole to bring out relative merits of different shapes. The new trench holes improved the film cooling effectiveness by allowing more residence time for coolant to spread laterally while directing smoothly onto the airfoil surface. While convex trench improved the centre-line effectiveness, straight trench improved the laterally-averaged and overall effectiveness at all blowing ratios. Concave trench improved the effectiveness at blowing ratios 0.5 and 1.0.


2009 ◽  
Vol 131 (4) ◽  
Author(s):  
Zhihong Gao ◽  
Diganta Narzary ◽  
Je-Chin Han

This paper is focused on the effect of film-hole configurations on platform film cooling. The platform is cooled by purge flow from a simulated stator-rotor seal combined with discrete-hole film cooling within the blade passage. The cylindrical holes and laidback fan-shaped holes are assessed in terms of film-cooling effectiveness and total pressure loss. Lined up with the freestream streamwise direction, the film holes are arranged on the platform with two different layouts. In one layout, the film-cooling holes are divided into two rows and more concentrated on the pressure side of the passage. In the other layout, the film-cooling holes are divided into four rows and loosely distributed on the platform. Four film-cooling hole configurations are investigated totally. Testing was done in a five-blade cascade with medium high Mach number condition (0.27 and 0.44 at the inlet and the exit, respectively). The detailed film-cooling effectiveness distributions on the platform were obtained using pressure sensitive paint technique. Results show that the combined cooling scheme (slot purge flow cooling combined with discrete-hole film cooling) is able to provide full film coverage on the platform. The shaped holes present higher film-cooling effectiveness and wider film coverage than the cylindrical holes, particularly at higher blowing ratios. The hole layout affects the local film-cooling effectiveness. The shaped holes also show the advantage over the cylindrical holes with lower total pressure loss.


Author(s):  
Zhihong Gao ◽  
Diganta Narzary ◽  
Je-Chin Han

This paper is focused on the effect of film hole configurations on platform film cooling. The platform is cooled by purge flow from a simulated stator-rotor seal combined with discrete-hole film cooling within the blade passage. The cylindrical holes and laidback fan-shaped holes are assessed in terms of film cooling effectiveness and total pressure loss. Lined up with the freestream streamwise direction, the film holes are arranged on the platform with two different layouts. In one layout, the film cooling holes are divided into two rows and more concentrated on the pressure side of the passage. In the other layout, the film cooling holes are divided into four rows and loosely distributed on the platform. Four film cooling hole configurations are investigated totally. Testing was done in a five-blade cascade with medium high Mach number condition (0.27 and 0.44 at the inlet and the exit, respectively). The detailed film cooling effectiveness distributions on the platform was obtained using pressure sensitive paint (PSP) technique. Results show that the combined cooling scheme (slot purge flow cooling combined with discrete hole film cooling) is able to provide full film coverage on the platform. The shaped holes present higher film cooling effectiveness and wider film coverage than the cylindrical holes, particularly at higher blowing ratios. The hole layout affects the local film cooling effectiveness. The shaped holes also show the advantage over the cylindrical holes with lower total pressure loss.


Author(s):  
Sang Hyun Oh ◽  
Dong Hyun Lee ◽  
Kyung Min Kim ◽  
Moon Young Kim ◽  
Hyung Hee Cho

An experimental investigation is conducted on the cooling effectiveness of full-coverage film cooled wall with impingement jets. Film cooling plate is made of stainless steel, thus the adiabatic film cooling effectiveness and the cooling effect of impingement jet underneath the film cooling plate are comprised in the cooling effectiveness. Infra-red camera is used to measure the temperature of film cooled surfaces. Experiments are conducted with different film cooling hole angles, such as 35° and 90°. Diameters of both film cooling holes and impinging jet holes are 5 mm. The jet Reynolds number base on the hole diameter (Red) ranges from 3,000 to 5,000 and equivalent blowing ratios (M) varies from 0.3 to 0.5, respectively. The distance between the injection plate and the film cooling plate is 1, 3 and 5 times of the hole diameter. The streamwise and spanwise hole spacing to the hole diameter ratio (p/d) are 3 for both the film cooling hole plate and the impingement jet hole plate. The 35° angled film cooling hole arrangement shows higher film cooling effectiveness than the 90° film cooling hole arrangement. As the blowing ratio increases, the cooling effectiveness is enhanced for both the 35° almost constant regardless of H/d, while H/d = 1 shows a minimum value for the angled film cooling hole.


Author(s):  
Travis B. Watson ◽  
Kyle R. Vinton ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

Abstract The effect of film cooling hole inlet geometry is experimentally investigated in this study. Detailed film cooling effectiveness distributions are obtained on a flat plate using Pressure Sensitive Paint (PSP). The inlet of a traditional 12°-12°-12°, laidback, fanshaped hole varies from a traditional “round” opening to an oblong, racetrack shaped opening. In this study, a single racetrack inlet with an aspect ratio of 2:1 is compared to the round inlet. For both designs, the holes are inclined at θ = 30° relative to the mainstream. Blowing ratios of 0.5, 1.0, and 1.5 are considered as the coolant–to–mainstream density ratio varies between 1.0 and 4.0. For all cases, the freestream turbulence intensity is maintained at 7.5%. With the introduction of the racetrack shaped inlet, the coolant spreads laterally across the diffuse, laidback fanshaped outlet. The centerline film cooling effectiveness is reduced with the enhanced lateral spread of the coolant. However, the benefit of the shaped inlet is also observed with an increase in the area averaged film cooling effectiveness, compared to the traditional round inlet. Not only does the shaped inlet promote spreading of the coolant, it is also believed the racetrack shape suppresses turbulence within the hole allowing for enhanced film cooling protection near the film cooling holes.


Author(s):  
N. Meah ◽  
M. Hunt ◽  
R. Evans ◽  
T. Racz ◽  
J. Verdicchio ◽  
...  

This paper describes the application of geometry morphing, integrated with meshing and flow simulation, to the topological optimisation of gas turbine film cooling holes. Using a Genetic Algorithm to manage the digitally represented geometry a wide range of novel cooling hole shapes can be generated and useful improvements in film cooling effectiveness are observed. The simulations suggest that modified vortical flow structures are responsible for improved coolant distribution and coverage at hole exit.


Sign in / Sign up

Export Citation Format

Share Document