Numerical Study on the Effects of Freestream Turbulence on Antivortex Film Cooling Design at High Blowing Ratio

Author(s):  
Timothy W. Repko ◽  
Andrew C. Nix ◽  
Can Uysal ◽  
James D. Heidmann

An advanced, high-effectiveness film cooling design, the antivortex hole (AVH) has been investigated by several research groups and shown to mitigate or counter the vorticity generated by conventional holes and increase film effectiveness at high blowing ratios and low freestream turbulence levels. The effects of increased turbulence on an AVH geometry were previously investigated in a preliminary steady computational fluid dynamics (CFD) study by Hunley et al. on the film effectiveness and net heat flux reduction (NHFR) at high blowing ratio. The current paper presents the results of an extended numerical parametric study, which attempts to separate the effects of turbulence intensity and length scale on film cooling performance of the AVH concept at high blowing ratio (2.0) and density ratio (2.0). In this extended study, steady Reynolds-averaged Navier–Stokes (RANS) analysis was performed with turbulence intensities of 5, 10, and 20% and length scales based on cooling hole diameter of Λx/dm = 1, 3, and 6. Increasing turbulence intensity was shown to increase the centerline, span-averaged, and area-averaged adiabatic film cooling effectiveness and NHFR. Larger turbulent length scales in the steady RANS analysis were shown to have little to no effect on the centerline, span-averaged, and area-averaged adiabatic film cooling effectiveness and NHFR at lower turbulence levels, but moderate effect at the highest turbulence levels investigated. Heat transfer results were in good agreement with the findings from adiabatic cases from previous work. Unsteady RANS results also provided supplementary flow visualization for the AVH film cooling flow under varying turbulence levels.

Author(s):  
Timothy W. Repko ◽  
Andrew C. Nix ◽  
James D. Heidmann

An advanced, high-effectiveness film-cooling design, the anti-vortex hole (AVH) has been investigated by several research groups and shown to mitigate or counter the vorticity generated by conventional holes and increase film effectiveness at high blowing ratios and low freestream turbulence levels. [1, 2] The effects of increased turbulence on the AVH geometry were previously investigated and presented by researchers at West Virginia University (WVU), in collaboration with NASA, in a preliminary CFD study [3] on the film effectiveness and net heat flux reduction (NHFR) at high blowing ratio and elevated freestream turbulence levels for the adjacent AVH. The current paper presents the results of an extended numerical parametric study, which attempts to separate the effects of turbulence intensity and length-scale on film cooling effectiveness of the AVH. In the extended study, higher freestream turbulence intensity and larger scale cases were investigated with turbulence intensities of 5, 10 and 20% and length scales based on cooling hole diameter of Λx/dm = 1, 3 and 6. Increasing turbulence intensity was shown to increase the centerline, span-averaged and area-averaged adiabatic film cooling effectiveness. Larger turbulent length scales were shown to have little to no effect on the centerline, span-averaged and area-averaged adiabatic film-cooling effectiveness at lower turbulence levels, but slightly increased effect at the highest turbulence levels investigated.


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

Detailed film cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The applicability of the PSP technique is expanded to include a coolant-to-mainstream density ratio of 1.4. The effect of density ratio on the film cooling effectiveness is coupled with varying blowing ratio (M = 0.25–2.0), freestream turbulence intensity (Tu = 1%–12.5%), and film hole geometry. The effectiveness distributions are obtained on three separate flat plates containing either simple angle, cylindrical holes, simple angle, fanshaped holes (α = 10°), or simple angle, laidback, fanshaped holes (α = 10°, γ = 10°). In all three cases, the film cooling holes are angled at θ = 35° from the mainstream flow. Using the PSP technique, the combined effects of blowing ratio, turbulence intensity, and density ratio are captured for each film cooling geometry. The detailed film cooling effectiveness distributions, for cylindrical holes, clearly show the effectiveness at the lowest blowing ratio is enhanced at the lower density ratio (DR = 1). However, as the blowing ratio increases, a transition occurs, leading to increased effectiveness with the elevated density ratio (DR = 1.4). In addition, the PSP technique captures an upstream shift of the coolant jet reattachment point as the density ratio increases or the turbulence intensity increases (at moderate blowing ratios for cylindrical holes). With the decreased momentum of the shaped film cooling holes, the greatest film cooling effectiveness is obtained at the lower density ratio (DR = 1.0) over the entire range of blowing ratios considered. In all cases, as the freestream turbulence intensity increases, the film effectiveness decreases; this effect is reduced as the blowing ratio increases for all three film hole configurations.


2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

Detailed film-cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The applicability of the PSP technique is expanded to include a coolant-to-mainstream density ratio of 1.4. The effect of density ratio on the film-cooling effectiveness is coupled with varying blowing ratio (M=0.25–2.0), freestream turbulence intensity (Tu=1–12.5%), and film hole geometry. The effectiveness distributions are obtained on three separate flat plates containing either simple angle, cylindrical holes, simple angle, fanshaped holes (α=10 deg), or simple angle, laidback, fanshaped holes (α=10 deg and γ=10 deg). In all three cases, the film-cooling holes are angled at θ=35 deg from the mainstream flow. Using the PSP technique, the combined effects of blowing ratio, turbulence intensity, and density ratio are captured for each film-cooling geometry. The detailed film-cooling effectiveness distributions, for cylindrical holes, clearly show that the effectiveness at the lowest blowing ratio is enhanced at the lower density ratio (DR=1). However, as the blowing ratio increases, a transition occurs, leading to increased effectiveness with the elevated density ratio (DR=1.4). In addition, the PSP technique captures an upstream shift of the coolant jet reattachment point as the density ratio increases or the turbulence intensity increases (at moderate blowing ratios for cylindrical holes). With the decreased momentum of the shaped film-cooling holes, the greatest film-cooling effectiveness is obtained at the lower density ratio (DR=1.0) over the entire range of blowing ratios considered. In all cases, as the freestream turbulence intensity increases, the film effectiveness decreases; this effect is reduced as the blowing ratio increases for all three film hole configurations.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.


2018 ◽  
Vol 35 (1) ◽  
pp. 1-9 ◽  
Author(s):  
Guangchao Li ◽  
Yukai Chen ◽  
Zhihai Kou ◽  
Wei Zhang ◽  
Guochen Zhang

AbstractThe trunk-branch hole was designed as a novel film cooling concept, which aims for improving film cooling performance by producing anti-vortex. The trunk-branch hole is easily manufactured in comparison with the expanded hole since it consists of two cylindrical holes. The effect of turbulence on the film cooling effectiveness with a trunk-branch hole injection was investigated at the blowing ratios of 0.5, 1.0, 1.5 and 2.0 by numerical simulation. The turbulence intensities from 0.4 % to 20 % were considered. The realizable$k - \varepsilon $turbulence model and the enhanced wall function were used. The more effective anti-vortex occurs at the low blowing ratio of 0.5 %. The high turbulence intensity causes the effectiveness evenly distributed in the spanwise direction. The increase of turbulence intensity leads to a slight decrease of the spanwise averaged effectiveness at the low blowing ratio of 0.5, but a significant increase at the high blowing ratios of 1.5 and 2.0. The optimal blowing ratio of the averaged surface effectiveness is improved from 1.0 to 1.5 when the turbulence intensity increases from 0.4 % to 20 %.


2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

An experimental investigation of film cooling jet structure using two-dimensional particle image velocimetry (PIV) has been completed for cylindrical, simple angle (θ=35 deg) film cooling holes. The PIV measurements are coupled with detailed film cooling effectiveness distributions on the flat plate obtained using a steady state, pressure sensitive paint (PSP) technique. Both the flow and surface measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied from 1.2% to 12.5%. With this traditional film cooling configuration, the blowing ratio was varied from 0.5 to 1.5 to compare the jet structure of relatively low and high momentum cooling flows. Velocity maps of the coolant flow (in the streamwise direction) are obtained on three planes spanning a single hole: centerline, 0.25D, and 0.5D (outer edge of the film cooling hole). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets are obtained near the cooled surface. In addition, turbulent fluctuations are obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV (both instantaneous and time averaged) with detailed film cooling effectiveness distributions on the surface (PSP) provides a more complete view of the coolant jet-mainstream flow interaction. Near the edge of the film cooling holes, the turbulent mixing increases, and as a result the film cooling effectiveness decreases. Furthermore, the PIV measurements show the increased mixing of the coolant jet with the mainstream at the elevated freestream turbulence level resulting in a reduction in the jet to effectively protect the film cooled surface.


Author(s):  
A. Newman ◽  
S. Xue ◽  
W. Ng ◽  
H. K. Moon ◽  
L. Zhang

An experimental study was performed to measure surface Nusselt number and film cooling effectiveness on a film cooled first stage nozzle guide vane using a transient thin film gauge (TFG) technique. The information presented attempts to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a 1st stage NGV. Tests were performed at engine representative Mach and Reynolds numbers and high inlet turbulence intensity and large length scale at the Virginia Tech Transonic Cascade facility. Three exit Mach/Reynolds number conditions were tested: 1.0/1,400,000; 0.85/1,150,000; and 0.60/850,000 where Reynolds number is based on exit conditions and vane chord. At Mach/Reynolds numbers of 1.0/1,450,000 and 0.85/1,150,000 three blowing ratio conditions were tested: BR = 1.0, 1.5, and 2.0. At a Mach/Reynolds number of 0.60/850,000, two blowing ratio conditions were tested: BR = 1.5 and 2.0. All tests were performed at inlet turbulence intensity of 12% and length scale normalized by the cascade pitch of 0.28. Film cooling effectiveness and heat transfer results compared well with previously published data, showing a marked effectiveness improvement (up to 2.5x) over the showerhead only NGV and agreement with published showerhead-shaped hole data. Net heat flux reduction was shown to increase substantially (average 2.6x) with the addition of shaped holes, with an increase (average 1.6x) in required coolant mass flow. Boundary layer transition location was shown to be within a consistent region on the suction side regardless of blowing ratio and exit Mach number.


2013 ◽  
Vol 716 ◽  
pp. 699-704 ◽  
Author(s):  
Ping Dai ◽  
Nai Yun Yu

Effects of hole shapes on film cooling effectiveness downstream of one row of film holes at the blade were investigated using a three-dimensional finite volume method and multi-block technique. The present study also received velocity vectors about different hole shapes. The hole geometries studied include standard cylindrical hole and forward diffused shaped hole and converging slot-hole. It was found that the film cooling effectiveness of cylindrical holes obviously declined along with increasing the blowing ratio. Results of the shaped holes configuration present a marked improvement, with a high effectiveness at the lateral area between adjacent holes and effectiveness of the converging slot-hole was superior to other holes in various blowing ratios. The film cooling effectiveness realized by the slot-holes compared to the cylindrical and forward diffused shaped holes was more excelled at downstream of the intersection of the two slot-holes. The converging slot-hole and forward diffused shaped hole can reduce the vortex intensity, and then enhance the film cooling effectiveness.


Author(s):  
Diganta P. Narzary ◽  
Kuo-Chun Liu ◽  
Je-Chin Han

Detailed parametric study of film-cooling effectiveness was carried out on a turbine blade platform of a five-blade linear cascade. The parameters chosen were freestream turbulence intensity, upstream stator-rotor purge flow rate, discrete-hole film-cooling blowing ratio, and coolant-to-mainstream density ratio. The measurement technique adopted was temperature sensitive paint (TSP) technique. Two turbulence intensities of 4.2% and 10.5%; three purge flows between the range of 0.25% and 0.75% of mainstream flow rate; three blowing ratios between 1.0 and 1.8; and three density ratios between 1.1 and 2.2 were investigated. Purge flow was supplied via a typical double-toothed stator-rotor seal, whereas the discrete-hole film-cooling was accomplished via two rows of cylindrical holes arranged along the length of the platform. The inlet and the exit Mach numbers were 0.27 and 0.44, respectively. Reynolds number of the mainstream flow was 7.5 * 105 based on the exit velocity and chord length of the blade. Results indicated that platform film-cooling effectiveness decreased with turbulence intensity, increased with purge flow rate and density ratio, and possessed an optimum blowing ratio value.


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Michael D. Clemenson

An experimental investigation of film cooling jet structure using two-dimensional, particle image velocimetry (PIV) has been completed for cylindrical, simple angle (θ = 35°) film cooling holes. The PIV measurements are coupled with detailed film cooling effectiveness distributions on the flat plate obtained using a steady state, pressure sensitive paint (PSP) technique. Both the flow and surface measurements were performed in a low speed wind tunnel where the freestream turbulence intensity was varied from 1.2% to 12.5%. With this traditional film cooling configuration, the blowing ratio was varied from 0.5–1.5 to compare the jet structure of relatively low and high momentum cooling flows. Velocity maps of the coolant flow (in the streamwise direction) are obtained on three planes spanning a single hole: centerline, 0.25D, and 0.5D (outer edge of the film cooling hole). From the seeded jets, time averaged, mean velocity distributions of the film cooling jets are obtained near the cooled surface. In addition, turbulent fluctuations are obtained for each flow condition. Combining the detailed flow field measurements obtained using PIV (both instantaneous and time averaged) with detailed film cooling effectiveness distributions on the surface (PSP), provides a more complete view of the coolant jet–mainstream flow interaction. Near the edge of the film cooling holes, the turbulent mixing increases, and as a result the film cooling effectiveness decreases. Furthermore, the PIV measurements show the increased mixing of the coolant jet with the mainstream at the elevated freestream turbulence level resulting in a reduction of the jet to effectively protect the film cooled surface.


Sign in / Sign up

Export Citation Format

Share Document