An Analytical Solution to Heat and Mass Transfer in Hollow Fiber Membrane Contactors for Liquid Desiccant Air Dehumidification

2011 ◽  
Vol 133 (9) ◽  
Author(s):  
Li-Zhi Zhang

Hollow fiber membrane contactors are used in air dehumidification. The benefit of this technology is that the liquid desiccant is not in a direct contact with the process air; therefore, the problem of liquid droplets crossover is prevented. The equations governing the heat and moisture transfer from the air to the liquid, through the membranes, are described. An analytical solution is obtained for the dimensionless differential equations, with which the dehumidification effectiveness could be estimated by simple algebraic calculations. It provides a convenient yet accurate tool for the component design and system optimization. The model is validated by experiments. The effects of varying operating conditions on system performance are investigated. It is found that the total number of transfer units for sensible heat and the overall Lewis number are the most dominant parameters influencing heat and mass transfer.

2013 ◽  
Vol 302 ◽  
pp. 20-25
Author(s):  
Lu Ma ◽  
Shu Li Wang ◽  
Jian Wang ◽  
En Tian Li ◽  
Xin Cao

A dynamic model of mass transfer was developed with mass transfer equation and mass transfer differential equation according to two film theory for the simultaneous transport of hydrogen sulfide through hollow fiber membrane (HFM) contactors while using N-methyldiethanolamine (MDEA) as the chemical solvent. The model results are in excellent agreement with the experimental data. The results indicate that the removal of H2S increased while increasing concentration of MDEA and gas pressure, however, the removal of H2S decreases while increasing gas velocity. The concentration of H2S increases at the same place in the lumen while increasing gas velocity. There is serious decreasing amplitude of axial concentration of H2S during the initial stage, but it slows down at half of the length and a great reduction of H2S concentration in radial direction with the increase of the length. The decreasing amplitude is dropped due to the concentration of H2S decreased in radial direction. The model can indicate H2S removal rate in given operational conditions and offer theory evidence for the design of membrane contactor. Natural gas is believed to play a vital role in the next few decades for industrial and domestic utilization. It is considered as one of the cleanest and safest of all energy sources. However, nature gas is not a pure hydrocarbon and sometimes it has some sour gases such as hydrogen sulfide which has high toxicity. Hydrogen sulfide can not only corrode equipment and transmission pipeline under aerobic and hot humid conditions but also cause catalyst poisoning, even serious threaten the safety of human. Wet desulphurization is widely used for natural gas treatment and aqueous solutions of alkanolamines are often used as absorption solvent. Among these alkanolamines, MDEA as an absorption solvent of acid gases is widely used today because it possesses the characteristics such as higher H2S selectivity, bigger absorption capacity, lower regeneration energy, smaller hot-degradation and lower circulating load. But desulphurization unit can be seriously corroded in the sulfur removal process. On the other hand, these conventional processes such as absorption towers, packed and plate columns possess many disadvantages such as flooding, foam formation, and demand high capital and operating costs. So the technology meets a certain obstacles. Recently, new processes using gas–liquid membrane contactors as gas absorption devices have been a subject of great interest. Among the diversity of membrane geometries available for membrane contactors, hollow-fiber membrane contactors are favored due to their high surface/volume ratio for separation which is 30-50 times compared with traditional absorbers. This type of process offers several practical advantages including low energy and operating costs, simplicity and occupying small area. In addition, membrane contactors as unit equipment can be combined according to actual need. [4~5] used polypropylene hollow fiber membrane as the absorber and MDEA as the chemical solvent for the absorption of H2S via changing operating conditions (e.g. temperature, pressure, the concentration of the solvent, flux of gas-liquid phase) and studied the influence of the changes to mass transfer coefficient and sulfur removal efficiency. The results indicate that the sulfur removal efficiency can be 95% above by optimizing the operating conditions. At home and abroad, comprehensive two-dimensional mathematical models were developed based on differential equation. Wang [6] simulated the absorption of CO2 using different absorption medium in hollow fiber membrane contactors. But they did not consider the effect of mixed gas. Chen [7] modeled the distribution of reactants and products concentration in the shell side in different typ es of reaction. However, the model can not obtain the concentration of H2S in the lumen. Rami Faiz [8] modeled the distribution of acid gas, but the mathematical model was not validated by the experimental work.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Si-Min Huang ◽  
Li-Zhi Zhang ◽  
Kai Tang ◽  
Li-Xia Pei

The fluid flow and conjugate heat and mass transfer across a hollow fiber membrane tube bundle used for liquid desiccant air dehumidification are investigated. In this process, humid air flows across the fiber bank and salt solution flows inside the fibers packed in a shell. They exchange heat and moisture through the membranes. To overcome the difficulties in the direct modeling of the whole tube bundle, a representative cell, which comprises of a single fiber, a solution stream inside the fiber, and an air stream flowing across the fiber, is selected as the calculation domain. The liquid flow inside the fibers is assumed to be laminar due to the low Reynolds numbers, while the air flow across the bank is considered to be turbulent as a result from the disturbances from the numerous fibers. The governing equations for fluid flow and heat and mass transfer in the two flows and in the membrane are coupled together and solved numerically with a self-built code. Experimental work on hollow fiber membrane-based liquid desiccant air dehumidification is performed to validate the model. The fundamental data on friction factor, Nusselt and Sherwood numbers on both the shell and the tube sides are then obtained for Re = 300–600.


2011 ◽  
Vol 356-360 ◽  
pp. 1362-1366
Author(s):  
Wei Feng Zhang ◽  
Zhong Hua Lin

Experimental on CO2 removal from flue gas using polypropylene hollow fiber membrane contactors were conducted in this study. Absorbents including aqueous PG, SG were used to absorb CO2 in the experiments, and comparing with aqueous MEA. The experimental results showed that the mass transfer rate of PG and SG increased gradually in experiments while the absorbent concentration can not be elevated without limitation. That may show the mass transfer rate will be eventually saturated at a certain concentration value. The aqueous PG can be selected to absorb CO2 in membrane contactors at a lower liquid flow rate to reduce the potential to wet the membrane. Comparing PG and SG with MEA. The performance of PG is superior to SG and MEA under the same operating conditions.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3320
Author(s):  
Sebastian Englart ◽  
Krzysztof Rajski

The membrane-based desiccant liquid air dehumidification system is a promising technology for efficient humidity control in buildings. The use of a membrane module allows, among other things, for a compact design with a relatively large heat and mass transfer area and eliminates carryover of solution droplets. In this paper, a cross-flow, hollow-fiber membrane module was proposed for air dehumidification and regeneration of lithium chloride. A two-dimensional heat and mass transfer model for cross-flow in a membrane module used for air dehumidification and liquid desiccant regeneration was developed. The effectiveness, moisture removal rate and moisture removal rate were studied numerically and validated against experimental results. Based on the numerical simulations, the most favorable ranges of operating conditions were determined. It was found that the operating conditions significantly impact the dehumidification performance. The proposed dehumidifier maintains its performance in a wide range of inlet air humidity ratios. For dehumidification, the recommended temperature of the incoming solution was in the range of 14–18 °C, while for regeneration the solution range was 40–50 °C. The packing fraction was suggested in the range of 0.30–0.40. These results can help design membrane-based liquid dehumidification systems.


2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Sher Ahmad ◽  
Gabriela Vollet Marson ◽  
Waheed Ur Rehman ◽  
Mohammad Younas ◽  
Sarah Farrukh ◽  
...  

Abstract Background In this research work, a coupled heat and mass transfer model was developed for salt recovery from concentrated brine water through an osmotic membrane distillation (OMD) process in a hollow fiber membrane contactor (HFMC).The model was built based on the resistance-in-series concept for water transport across the hydrophobic membrane. The model was adopted to incorporate the effects of polarization layers such as temperature and concentration polarization, as well as viscosity changes during concentration. Results The modeling equations were numerically simulated in MATLAB® and were successfully validated with experimental data from literature with a deviation within the range of 1–5%. The model was then applied to study the effects of key process parameters like feed concentrations, osmotic solution concentration, feed, and osmotic solution flow rates and feed temperature on the overall heat and mass transfer coefficient as well as on water transport flux to improve the process efficiency. The mass balance modeling was applied to calculate the membrane area based on the simulated mass transfer coefficient. Finally, a scale-up for the MD process for salt recovery on an industrial scale was proposed. Conclusions This study highlights the effect of key parameters for salt recovery from wastewater using the membrane distillation process. Further, the applicability of the OMD process for salt recovery on large scale was investigated. Sensitivity analysis was performed to identify the key parameters. From the results of this study, it is concluded that the OMD process can be promising in salt recovery from wastewater.


Sign in / Sign up

Export Citation Format

Share Document