New Correlations for Thermal Resistances of Vertical Single U-Tube Ground Heat Exchanger

Author(s):  
Quan Liao ◽  
Chao Zhou ◽  
Wenzhi Cui ◽  
T. C. Jen

A new 2D numerical model of a single U-tube ground heat exchanger is proposed and a four-thermal-resistance model is adopted to evaluate the effective pipe-to-borehole, pipe-to-pipe, and borehole-to-borehole thermal resistances. The influence of temperature distributions on both borehole surface and outer diameter of two pipes to these thermal resistances has been thoroughly studied. The best-fit correlations of effective pipe-to-borehole, pipe-to-pipe, and borehole-to-borehole thermal resistances are proposed and compared with the available equations in the literature. It is found that the present correlations of thermal resistances for ground heat exchanger are more accurate than those of available formulas. Furthermore, based on these obtained thermal resistance correlations, an analytical model is proposed to evaluate the heat transfer performance of the ground heat changer.

2012 ◽  
Vol 516-517 ◽  
pp. 316-321
Author(s):  
Zhong Yi Yu ◽  
Yan Hua Chen ◽  
Xiao Liang Tang ◽  
Jian Ping Lei

According to the application conditions of horizontal ground heat exchanger(HGHE) under artificial lake, this paper uses numerical simulation method to do dynamic simulation research of the heat transfer performance of HGHE, analyzes the effect of connection mode and pipe flow velocity on heat transfer performance of HGHE in detail,puts forward efficient HGHE loop formation mode,and will provide effective technical support for ground-source heat pump system design with HGHE.


2014 ◽  
Vol 580-583 ◽  
pp. 2488-2491
Author(s):  
Rong Hui Wang ◽  
Qing Hua Wang ◽  
Ye Feng

5 radial heat exchange wells were designed, and the different angle drilling, drilling pipe, and grouting backfill construction technology was studied. In addition, the heat transfer performance of the buried radial heat exchange wells was tested. The results show that, design of pipe equipment is feasible, construction is convenient, and the ratio of backfill material is reasonable; the heat transfer performance of 90 °buried tube is the best. The smaller the angle with the ground heat exchanger, the greater the heat exchange performance is affected by the surface temperature.


Author(s):  
Quan Liao ◽  
Chao Zhou ◽  
Wenzhi Cui ◽  
Tien-Chien Jen

The effective pipe-to-borehole and pipe-to-pipe thermal resistances of vertical single U-shape ground heat exchanger are numerically studied. The non-uniform temperature distributions along perimeter of both borehole and outside diameter of two pipes are taken into account to evaluate both the pipe-to-borehole and pipe-to-pipe thermal resistances. The best-fit correlations for these two thermal resistances are proposed and compared with the available equations in the literature. It is found that the present correlations of effective pipe-to-borehole and pipe-to-pipe thermal resistances are more accurate than those of available formulas.


Author(s):  
Koutaro TSUBAKI ◽  
Yuji KIMURA ◽  
Retsu HARADA ◽  
Yukari KAI ◽  
Yuichi MITSUTAKE

2020 ◽  
Vol 166 ◽  
pp. 20-34
Author(s):  
Chao Li ◽  
Yanling Guan ◽  
Jianhong Liu ◽  
Chao Jiang ◽  
Ruitao Yang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document