scholarly journals Specimen-Specific Finite Element Models for Predicting Fretting Wear in Total Hip Arthroplasty Tapers

2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Andrew P. Baumann ◽  
Oleg Vesnovsky ◽  
L. D. Timmie Topoleski ◽  
Finn E. Donaldson ◽  
Nicole L. L. McMinn ◽  
...  

Abstract Products from fretting wear and corrosion in the taper junction of total hip arthroplasty (THA) devices can lead to adverse local tissue reactions. Predicting damage as a function of design parameters would aid in the development of more robust devices. The objectives of this study were to develop an automated method for identifying areas of fretting wear on THA taper junctions, and to assess the predictive ability of a finite element model to simulate fretting wear in THA taper junctions. THA constructs were fatigue loaded, thus inducing damage on the stem taper. An automated imaging and analysis algorithm quantified fretting wear on the taper surfaces. Specimen-specific finite element models were used to calculate fretting work done (FWD) at the taper junction. Simulated FWD was correlated to imaged fretting wear. Results showed that the automated imaging approach identified fretting wear on the taper surface. Additionally, finite element models showed the greatest predictive ability for tapers exhibiting distal contact. Finite element models predicted an average of 30.3% of imaged fretting wear. With additional validation, the imaging and finite element techniques may be useful to manufacturers and regulators in the development and review of new THA devices.

2019 ◽  
pp. 112070001987738 ◽  
Author(s):  
Duncan W Cushnie ◽  
Brent A Lanting ◽  
Richard McCalden ◽  
Douglas DR Naudie ◽  
James L Howard

Introduction: Birmingham Hip Resurfacing (BHR) implants may be combined with a conventional femoral stem to create a modular metal-on-metal total hip arthroplasty (BHR MoM THA). There is little outcome data regarding this construct. This study examines midterm outcomes of BHR MoM THA compared to oxidised zirconium total hip arthroplasty (THA). Methods: A retrospective institutional review identified all patients receiving BHR MoM THA between April 2005 and February 2011 and a matched control cohort of zirconium THA patients. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), and SF-12 Health status scores were obtained. Revisions and complications were collected from clinical records. Radiographs were assessed for evidence of component malposition, loosening, osteolysis, or heterotopic ossification. Results: 63 modular BHR MoM THA were identified in 61 patients (36 with BHR cups, 27 with R3 cups) and 63 zirconium THA in 58 matched controls. Mean follow-up was 58 months. 14 BHR MoM THA hips (22.2%) were revised (4 infections, 1 dislocation, 9 soft tissue reactions) compared to 3 (4.8%) zirconium THA (all infections). At latest follow-up, 18.4% of surviving BHR MoM THA hips were painful compared to 0.5% of zirconium THA controls ( p < 0.001). WOMAC, HHS, and SF-12 did not differ significantly between surviving members of the 2 groups. Discussion: BHR MoM THA demonstrated a high revision rate, largely for adverse local soft tissue reaction and pain. Among those not revised, many reported some residual pain despite similar quality of life measures to those who received zirconium THA.


Heliyon ◽  
2019 ◽  
Vol 5 (6) ◽  
pp. e01767 ◽  
Author(s):  
Chethan K.N. ◽  
Mohammad Zuber ◽  
Shyamasunder Bhat N. ◽  
Satish Shenoy B. ◽  
Chandrakant R. Kini

2013 ◽  
Vol 21 (5) ◽  
pp. 493-500 ◽  
Author(s):  
Matthias Lerch ◽  
Nelly Weigel ◽  
Henning Windhagen ◽  
Max Ettinger ◽  
Fritz Thorey ◽  
...  

2017 ◽  
Vol 27 ◽  
pp. 83-87 ◽  
Author(s):  
Ross A. Miller ◽  
Jae Y. Ro ◽  
Mary R. Schwartz

2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Chih-Chien Hu ◽  
Tsan-Wen Huang ◽  
Shih-Jie Lin ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
...  

Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.


2005 ◽  
Vol 27 (8) ◽  
pp. 649-654 ◽  
Author(s):  
Markus Lengsfeld ◽  
Rene Burchard ◽  
Daniel Günther ◽  
Thomas Pressel ◽  
Jan Schmitt ◽  
...  

2002 ◽  
Author(s):  
D. Leone ◽  
L. Breglia ◽  
J. Gander ◽  
J. Ibets ◽  
C. Teeling ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document