A Comparison of Turbulence Levels From Particle Image Velocimetry and Constant Temperature Anemometry Downstream of a Low-Pressure Turbine Cascade at High-Speed Flow Conditions

2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Silvio Chemnitz ◽  
Reinhard Niehuis

Abstract The development and verification of new turbulence models for Reynolds-averaged Navier–Stokes (RANS) equation-based numerical methods require reliable experimental data with a deep understanding of the underlying turbulence mechanisms. High accurate turbulence measurements are normally limited to simplified test cases under optimal experimental conditions. This work presents comprehensive three-dimensional data of turbulent flow quantities, comparing advanced constant temperature anemometry (CTA) and stereoscopic particle image velocimetry (PIV) methods under realistic test conditions. The experiments are conducted downstream of a linear, low-pressure turbine cascade at engine relevant high-speed operating conditions. The special combination of high subsonic Mach and low Reynolds number results in a low density test environment, challenging for all applied measurement techniques. Detailed discussions about influences affecting the measured result for each specific measuring technique are given. The presented time mean fields as well as total turbulence data demonstrate with an average deviation of ΔTu<0.4% and ΔC/Cref<0.9% an extraordinary good agreement between the results from the triple sensor hot-wire probe and the 2D3C-PIV setup. Most differences between PIV and CTA can be explained by the finite probe size and individual geometry.

Author(s):  
Silvio Chemnitz ◽  
Reinhard Niehuis

Abstract The development and verification of new turbulence models for RANS equations based numerical methods require reliable experimental data with a deep understanding of the underlying turbulence mechanisms. High accurate turbulence measurements are normally limited to simplified test cases under optimal experimental conditions. This work presents comprehensive three-dimensional data of turbulent flow quantities, comparing advanced constant temperature anemometry (CTA) and stereoscopic particle image velocimetry (PIV) methods under realistic test conditions. The experiments are conducted downstream of a linear, low-pressure turbine cascade at engine relevant high speed operating conditions. The special combination of high subsonic Mach and low Reynolds number results in a low density test environment, challenging for all applied measurement techniques. Detailed discussions about influences affecting the measured result for each specific measuring technique is given. The presented time mean fields, as well as total turbulence data demonstrate with an average deviation of ΔTu < 0.4% and ΔC/Cref < 0.9% an extraordinary good agreement between the results from the triple sensor hot-wire probe and the 2D3C-PIV setup. Most differences between PIV and CTA can be explained by the finite probe size and individual geometry.


2021 ◽  
Vol 143 (7) ◽  
Author(s):  
Katharina Stichling ◽  
Maximilian Elfner ◽  
Hans-Jörg Bauer

Abstract In the present study, an existing test rig at the Institute of Thermal Turbomachinery (ITS), Karlsruhe Institute of Technology (KIT), designed for generic film cooling studies is adopted to accommodate time-resolved stereoscopic particle image velocimetry (SPIV) measurements. Through a similarity analysis, the test rig geometry is scaled by a factor of about 20. Operating conditions of hot gas and cooling air inlet and exit can be imposed that are compliant with realistic engine conditions including density ratio (DR). The cooling air is supplied by a parallel-to-hot gas coolant flow-configuration with a coolant Reynolds number of 30, 000. Time-resolved and time-averaged stereo article image velocimetry data for a film cooling flow at high DR and a range of blowing ratios are presented in this study. The investigated film cooling hole constitutes a 10 deg–10 deg–10 deg laidback fan-shaped hole with a wide spacing of P/D = 8 to insure the absence of jet interaction. The inclination angle amounts to 35 deg. The time-resolved data indicate transient behavior of the film cooling jet.


2021 ◽  
Author(s):  
Deb Banerjee ◽  
Ahmet Selamet ◽  
Rick Dehner

Abstract Stereoscopic Particle Image Velocimetry measurements are carried out at the inlet of a turbocharger compressor at four different shaft speeds from 80,000 rpm to 140,000 rpm and over the entire range of flow rates from choke to mild surge. This paper describes the procedure used in processing the PIV data leading to the estimates of turbulent length scales – integral, Taylor, and Kolmogorov, to enhance the fundamental understanding and characterization of the compressor inlet flow field. The analysis reveals that at most operating conditions the three different length scales have markedly different magnitudes, as expected, while they have somewhat similar qualitative distributions with respect to the duct radius. For example, at 80,000 rpm and at a flow rate of 15.7 g/s (mild surge), the longitudinal integral length scale is of the order of 15 mm, the Taylor scale is around 0.5 mm, and the Kolmogorov scale is about 10 microns. With the onset of flow reversal, the turbulent kinetic energy and turbulent intensity at the compressor inlet are observed to increase rapidly, while the magnitudes of the Kolmogorov scale and to a certain extent, the Taylor scale are found to decrease suggesting that the increased turbulence gives rise to even smaller flow structures. The variation of length scales with compressor shaft speed has also been studied.


Author(s):  
Deb Banerjee ◽  
Ahmet Selamet ◽  
Rick Dehner

Abstract Stereoscopic Particle Image Velocimetry measurements are carried out at the inlet of a turbocharger compressor at four different shaft speeds from 80,000 rpm to 140,000 rpm and over the entire range of flow rates from choke to mild surge. This paper describes the procedure used in processing the PIV data leading to the estimates of turbulent length scales - integral, Taylor, and Kolmogorov, to enhance the fundamental understanding and characterization of the compressor inlet flow field. The analysis reveals that at most operating conditions the three different length scales have markedly different magnitudes, as expected, while they have somewhat similar qualitative distributions with respect to the duct radius. For example, at 80,000 rpm and at a flow rate of 15.7 g/s (mild surge), the longitudinal integral length scale is of the order of 15 mm, the Taylor scale is around 0.5 mm, and the Kolmogorov scale is about 10 microns. With the onset of flow reversal, the turbulent kinetic energy and turbulent intensity at the compressor inlet are observed to increase rapidly, while the magnitudes of the Kolmogorov scale and to a certain extent, the Taylor scale are found to decrease suggesting that the increased turbulence gives rise to even smaller flow structures. The variation of length scales with compressor shaft speed has also been studied.


2018 ◽  
Vol 15 (148) ◽  
pp. 20180441 ◽  
Author(s):  
Per Henningsson ◽  
Lasse Jakobsen ◽  
Anders Hedenström

In this study, we explicitly examine the aerodynamics of manoeuvring flight in animals. We studied brown long-eared bats flying in a wind tunnel while performing basic sideways manoeuvres. We used particle image velocimetry in combination with high-speed filming to link aerodynamics and kinematics to understand the mechanistic basis of manoeuvres. We predicted that the bats would primarily use the downstroke to generate the asymmetries for the manoeuvre since it has been shown previously that the majority of forces are generated during this phase of the wingbeat. We found instead that the bats more often used the upstroke than they used the downstroke for this. We also found that the bats used both drag/thrust-based and lift-based asymmetries to perform the manoeuvre and that they even frequently switch between these within the course of a manoeuvre. We conclude that the bats used three main modes: lift asymmetries during downstroke, thrust/drag asymmetries during downstroke and thrust/drag asymmetries during upstroke. For future studies, we hypothesize that lift asymmetries are used for fast turns and thrust/drag for slow turns and that the choice between up- and downstroke depends on the timing of when the bat needs to generate asymmetries.