2020 ◽  
Vol 20 (7) ◽  
pp. 2858-2874
Author(s):  
Mostafa Abd El-Rady Abu-Zeid ◽  
Xiaolong Lu ◽  
Shaozhe Zhang

Abstract The low flux and high energy consumption problems of the conventional three-stage air-gap membrane distillation (AG-AG-AG)MD system caused by the low temperature difference between hot and cold feed at both sides of the membrane and high boundary layer thickness were solved successfully by replacing one of the three stages of air gaps by a water gap. The novel three-stage air-gap–water-gap membrane distillation (AG-AG-WG)MD system reduced energy consumption and increased flux due to efficient internal heat recycling by virtue of a water-gap module. Heat and mass transfer in novel and conventional three-stage systems were analyzed theoretically. Under a feed temperature of 45 °C, flow rate of 20 l/h, cooling temperature of 20 °C, and concentration of 340 ppm, the (AG-AG-WG)MD promoted flux by 17.59% and 211.69%, and gained output ratio (GOR) by 60.57% and 204.33% compared with two-stage (AG-WG)MD and one-stage AGMD, respectively. This work demonstrated the important role of a water gap in changing the heat and mass transfer where convection heat transfer across the water gap is faster by 24.17 times than conduction heat transfer through the air gap. The increase in flux and GOR economized the heating energy and decreased waste heat input into the system. Additionally, the number of MD stages could increase the achieving of a high flux with operation stability.


Desalination ◽  
2014 ◽  
Vol 354 ◽  
pp. 68-75 ◽  
Author(s):  
Qingfeng He ◽  
Pingli Li ◽  
Hongxin Geng ◽  
Chunyao Zhang ◽  
Juan Wang ◽  
...  

2017 ◽  
Vol 42 (5) ◽  
pp. 1951-1965 ◽  
Author(s):  
Atia E. Khalifa ◽  
Binash A. Imteyaz ◽  
Dahiru U. Lawal ◽  
Mohamed A. Abido

2020 ◽  
Vol 20 (7) ◽  
pp. 2884-2902
Author(s):  
Mostafa Abd El-Rady Abu-Zeid ◽  
Xiaolong Lu ◽  
Shaozhe Zhang

Abstract The negative effect of an air gap layer presented between the membrane and cooling plate on air gap membrane distillation (AGMD) performance was diminished largely by inserting a water gap membrane distillation (WGMD) module in series. The new design of air-gap–water-gap membrane distillation (AG-WG)MD was evaluated experimentally by comparing with an AGMD system under different operating conditions. In theory, mass and heat transfer in the new (AG-WG)MD and imitative AGMD systems were analyzed. Experimental outcomes showed that a new (AG-WG)MD design profoundly enhanced flux (Pd) and gained output ratio (GOR), and greatly decreased energy consumption (STEC) and heat input (EH.I). At a concentration of 5,000 mg/L, coolant temperature of 20 °C, and flow rate of 18 L/h, Pd was promoted by 76.26%, 40.84%, 35.45%, 30.91%, and GOR by 46.38%, 33.46%, 31.27%, 26.65%, in addition to STEC being reduced about 55.63%, 46.81%, 43.66%, 38.30%, and EH.I around 31.31%, 25.84%, 23.53%, 20.55%, from the AGMD to (AG-WG)MD system at feed temperatures of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. The outcomes proved that the AGMD performance could be significantly promoted by integrating with WGMD in a combined MD system. This combination increased the temperature difference across the membrane and decreased thermal-concentration boundary layers for the AGMD system.


Sign in / Sign up

Export Citation Format

Share Document