Evaluation of Gas Turbine/Compressor Control System Effectiveness Using Dynamic Simulation

Author(s):  
K. C. Chui ◽  
N. E. Pobanz ◽  
L. H. Chang

In centrifugal compressor installations that use a variable speed drive such as gas turbine, speed control is an effective method of controlling capacity. Compressors are normally protected from surging by an antisurge control loop which recycles the discharged gas to the suction of the compressor. In an upset condition which results in flow reduction, the two controllers may interact whereby performance of the surge controller may be compromised. In this paper, a dynamic simulation technique is used to illustrate the interaction.

Author(s):  
Fahmi Yunistyawan ◽  
Yunistyawan J Berchmans ◽  
Gembong Baskoro

This study implements the auto start control system on an electric motor 3 phase C4Feeding pump when the discharge pressure is low-low (4.3 kg /cm²). The C4 feeding pumpmotor was initially manually operated from the local control station, this was very ineffectiveand inefficient because it still relied on the field operator to operate the pump motor and whenthe plant was in normal operating it is very risk if the field operator late to operate motor then itwill impact to quality of the product, and if the delay time to operate motor is too long then planthave to shut down, therefore improvement is needed in the C4 feeding pump motor controlsystem. In this paper, various types of 3-phase motor control are explained which allow it to beapplied to the C4 feeding pump motor that are on-off, inverter, and variable speed drive andefficient selection of the three systems control of the motor. Software and hardware used in thisthesis work are DCS CENTUM VP Yokogawa.


Author(s):  
Alan Metzger

With the approach of the 1990 Clean Air Act compliance limits, the race is on to produce a functional, low-emission gas turbine. While most prototype Dry Low NOx (DLN) gas turbines are based on existing designs, the leap in technology required to meet NOx abatement levels is significant. To meet these goals, significant testing is required before low-emission turbines are ready for commercial production. This paper describes the test procedure that was used to verify control system and modulating valve technology for Turbo Power & Marine’s FT8-2™ Dry Low NOx prototype turbine. In particular, dynamic turbine simulation before the actual engine test will be discussed. The method and benefits of this test procedure will be presented.


Author(s):  
Joe S. Taylor

This paper presents how a major U.S. gas transmission and storage company restored gas storage peaking capacity by repowering obsolete gas turbine compressor units. Consumers Power Company’s Ray Field located in Macomb County, Michigan, USA, was developed as a 44 BCF working capacity gas storage field in 1966. Due to the high deliverability, the field is operated as a peaking reservoir, handling rates as high as 500 MMCFD on injection and 1,200 MMCFD on withdrawal. Ten (10) 2,750 horsepower gas turbine driven 4-stage centrifugal compressor units were installed in the mid to late 1960’s at the field. The compression is operated 2, 4 and 8 stage, as needed, to cover storage pressures of 450 to 1800 psig. Each centrifugal compressor is driven by a Pratt Whitney (PW) GG-12 Gas Generator firing into a Cooper-Bessemer (CB) RT-27 Power Turbine. By 1980 parts and maintenance services for the PW GG-12 Gas Generator became very expensive to non-existent. Aircraft use of the GG-12 (JT-12) had been phased out. Consumers Power, with 13 of these turbines on their system, was becoming the only remaining user. In the mid 1980’s four (4) of the Ray Field gas turbine compressor units were replaced with two (2) 6,000 horsepower reciprocating engine compressor units. These replacements maintained the deliverability of the field and provided salvageable engines and other parts to maintain the six (6) remaining turbines. However, by 1993 maintenance parts returned as a major problem as well as unit availability on the 6 remaining turbine units. In 1994 Consumers Power committed to a gas turbine unit repowering program as the preferred choice over unit replacement. Two (2) refurbished Solar Centaur T4500 Gas Turbine drives were purchased and installed to repower 2 of the obsolete turbine units. These installations have been very successful. Existing compressors, foundations, piping, coolers and auxiliary systems were re-used with only minor modification. The complete installed cost for repowering was about 33% of the cost experienced for replacement. Installation was completed within eight (8) months of project commitment. The low emission rates from the Solar SoLoNOx Combustors allowed short lead time (6 months) on air emissions permit. New sound attenuation enclosures met the new local noise ordinance and replaced equipment that had been a source of local complaint. PLC based controls improved reliability and flexibility of operation. The additional horsepower available from the T4500 Turbine (4,300 vs 2,750) allows for increased future capacity. Because of the success of the Ray Turbine Repowering Project, Consumers Power has committed to 2 more refurbished Solar Centaur T4500 Units to repower PW/CB Turbines at the St Clair Compressor Station. Solar is scheduled to delivery these 2 units by year-end 1995 for installation in 1996.


Author(s):  
R. B. Williams

The Alberta Gas Trunk Line’s new 20,000-hp gas turbine compressor set is one of the largest and most modern aircraft derivatives available to industry to date. This paper describes the various aspects of station and unit design for the compressor package. The additional operational flexibility gained as a result of adding this unit to our existing 12,500-hp station is described. The paper will also present a description of the station’s control system, including unit controls, surge controls, and other features of the instrumentation. Trunk Line is concerned with keeping the availability of the unit high, and as such, the paper will describe some features which help keep downtime to a minimum.


Proceedings ◽  
2019 ◽  
Vol 48 (1) ◽  
pp. 22
Author(s):  
Christian Briceño ◽  
Pedro Iglesias ◽  
Javier Martinez

Proper design of a pumping system requires the use of a pump curve and set-point curve system. Both have to be as close as possible to optimize energy use. This is achieved by control systems in which the type of control (flow or pressure) and the combination between fixed speed drive (FSD) pumps and variable speed drive (VSD) pumps are involved. The objective of this work is to determine the optimal number of FSD and VSD pumps for each flow rate range in order to discuss the classic design of pumping stations and their control systems. For this, a methodology is applied that defines the parametric form of the pump curve, efficiency curve, and set-point curve in relation to the most efficient point. In this way, dimensionless expressions are obtained and the influence of the set-point parameters on the design of the control system can be analyzed. Additionally, the method includes an expression that estimates the performance of the frequency inverter, which is based on the load and pump speed rotation. The application of the methodology to different case studies allows us to question many classic procedures for pumping stations. In summary, it can be concluded that the appropriate number of variable speed pumps for each control system cannot be established in advance but requires an in-depth study of different available options.


2012 ◽  
Vol 503-504 ◽  
pp. 1633-1638 ◽  
Author(s):  
Melih Cemal Kushan ◽  
Zhong Xiao Peng ◽  
Shu Zhi Peng

One of the key elements of servicing the aviation industry is the provision and maintenance of first class equipment. In order to ensure a secure and effective flight of aircrafts in aviation, the ground supporting equipment which enables the planes to get off the ground without delaying the flight plans, has to be kept ready at all times [1].