A Simplified Graphical Model of Air Cooler Using Mollier Diagram and Implementation in a Design Tool

Author(s):  
Fatemeh Esfandiari Nia ◽  
Dolf van Paassen

A validated heat and mass transfer model for an air cooler is developed and implemented in a design tool. The overall heat transfer coefficient is derived from the experiments, which can be written as a function of the heat transfer coefficients on the water and air side. For a good agreement between the measurements of a wet cooler and model solutions a correction in the heat transfer coefficients substantially is done. In addition, results obtained from the measurements indicate the heat transfer coefficient itself and the correlation between heat and mass transfer need to be adapted. Acceptable results are obtained when mass transfer coefficient is adjusted by a correction factor. The decrease in heat transfer is observed with increase in dehumidification and the same is concluded from the coupling of heat and mass transfer. The fins are not completely wet, which means an analogy between sensible and latent heat only exists partly. The corrected model is implemented in the studies of advanced evaporative air conditioning systems where it is used to construct a graphical model based on rules for transients in the Mollier diagram of humid air. Preliminary calculations show that it is very accurate and useful for the simulation of controlled air handling systems although it is very fast resulting of the short calculation time of the simplified models.

Author(s):  
Fatemeh Esfandiari Nia ◽  
Dolf van Paassen

This paper describes an improved class of heat and mass transfer air cooler model. The model is based on the approach of Green [1]. It delivers a compact and fast model that is appropriate for year round simulations of air conditioning systems. The model is validated through a set of experiments in the laboratory with an air cooler of eight rows. The heat transfer coefficients have been derived from the standard relations. For a good agreement between the measurements of a wet cooler and the model solutions, a substantial correction in the heat transfer coefficients is needed. In addition, the results obtained from the measurements indicated that the heat transfer coefficient itself and the correlation between heat and mass transfer had to be adapted. Acceptable results were obtained when mass transfer coefficient was adjusted by a correction factor. The decrease in heat transfer has been observed with an increase in dehumidification and the same could be concluded from the coupling of heat and mass transfer. The fins are not completely wet, which implies that an analogy between sensible and latent heat only partly exists. The model does not take wetness of the pipe into account. To overcome this problem, the Lewis number is modulated, based on the degree of dehumidification. In other words, the smaller mass transfer coefficient, there is the higher the dehumidification.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Jatuporn Kaew-On ◽  
Somchai Wongwises

The evaporation heat transfer coefficients and pressure drops of R-410A and R-134a flowing through a horizontal-aluminium rectangular multiport mini-channel having a hydraulic diameter of 3.48 mm are experimentally investigated. The test runs are done at refrigerant mass fluxes ranging between 200 and 400 kg/m2s. The heat fluxes are between 5 and 14.25 kW/m2, and refrigerant saturation temperatures are between 10 and 30 °C. The effects of the refrigerant vapour quality, mass flux, saturation temperature and imposed heat flux on the measured heat transfer coefficient and pressure drop are investigated. The experimental data show that in the same conditions, the heat transfer coefficients of R-410A are about 20–50% higher than those of R-134a, whereas the pressure drops of R-410A are around 50–100% lower than those of R-134a. The new correlations for the evaporation heat transfer coefficient and pressure drop of R-410A and R-134a in a multiport mini-channel are proposed for practical applications.


1993 ◽  
Vol 115 (4) ◽  
pp. 231-236 ◽  
Author(s):  
V. B. Sharma ◽  
S. C. Mullick

An approximate method for calculation of the hourly output of a solar still over a 24-hour cycle has been studied. The hourly performance of a solar still is predicted given the values of the insolation, ambient temperature, wind heat-transfer coefficient, water depth, and the heat-transfer coefficient through base and sides. The proposed method does not require graphical constructions and does not assume constant heat-transfer coefficients as in the previous methods. The possibility of using the values of the heat-transfer coefficients for the preceding time interval in the heat balance equations is examined. In fact, two variants of the basic method of calculation are examined. The hourly rate of evaporation is obtained. The results are compared to those obtained by numerical solution of the complete set of heat balance equations. The errors from the approximate method in prediction of the 24-hour output are within ±1.5 percent of the values from the numerical solution using the heat balance equations. The range of variables covered is 5 to 15 cms in water depth, 0 to 3 W/m2K in a heat-transfer coefficient through base and sides, and 5 to 40 W/m2K in a wind heat-transfer coefficient.


Author(s):  
Nirm V. Nirmalan ◽  
Ronald S. Bunker ◽  
Carl R. Hedlung

A new method has been developed and demonstrated for the non-destructive, quantitative assessment of internal heat transfer coefficient distributions of cooled metallic turbine airfoils. The technique employs the acquisition of full-surface external surface temperature data in response to a thermal transient induced by internal heating/cooling, in conjunction with knowledge of the part wall thickness and geometry, material properties, and internal fluid temperatures. An imaging Infrared camera system is used to record the complete time history of the external surface temperature response during a transient initiated by the introduction of a convecting fluid through the cooling circuit of the part. The transient data obtained is combined with the cooling fluid network model to provide the boundary conditions for a finite element model representing the complete part geometry. A simple 1D lumped thermal capacitance model for each local wall position is used to provide a first estimate of the internal surface heat transfer coefficient distribution. A 3D inverse transient conduction model of the part is then executed with updated internal heat transfer coefficients until convergence is reached with the experimentally measured external wall temperatures as a function of time. This new technique makes possible the accurate quantification of full-surface internal heat transfer coefficient distributions for prototype and production metallic airfoils in a totally non-destructive and non-intrusive manner. The technique is equally applicable to other material types and other cooled/heated components.


2017 ◽  
Vol 15 (3) ◽  
pp. 467
Author(s):  
Ravinder Kumar Sahdev ◽  
Mahesh Kumar ◽  
Ashwani Kumar Dhingra

In this paper, convective and evaporative heat transfer coefficients of the Indian groundnut were computed under indoor forced convection drying (IFCD) mode. The groundnuts were dried as a single thin layer with the help of a laboratory dryer till the optimum safe moisture storage level of 8 – 10%. The experimental data were used to determine the values of experimental constants C and n in the Nusselt number expression by a simple linear regression analysis and consequently, the convective heat transfer coefficient (CHTC) was determined. The values of CHTC were used to calculate the evaporative heat transfer coefficient (EHTC). The average values of CHTC and EHTC were found to be 2.48 W/m2 oC and 35.08 W/m2 oC, respectively. The experimental error in terms of percent uncertainty was also estimated. The experimental error in terms of percent uncertainty was found to be 42.55%. The error bars for convective and evaporative heat transfer coefficients are also shown for the groundnut drying under IFCD condition.


1986 ◽  
Vol 108 (1) ◽  
pp. 4-8 ◽  
Author(s):  
T. Kumada ◽  
T. Hirota ◽  
N. Tamura ◽  
R. Ishiguro

Some of the previously reported heat transfer coefficients with evaporation are fairly large as compared with those of a dry body under similar hydrodynamic conditions. In order to clarify this curious enhancement of heat transfer, a method of error evaluation was developed and applied to correct the experimental errors in the recently reported results. An experimental study was also made on turbulent heat and mass transfer of air flowing over a water surface. The present and the previously reported experimental results revealed that the heat transfer coefficient with evaporation agrees with that of a dry body without evaporation, within experimental error, if the erroneous heat inputs into the liquid are properly corrected according to the proposed method.


2000 ◽  
Author(s):  
M. Kumagai ◽  
R. S. Amano ◽  
M. K. Jensen

Abstract A numerical and experimental investigation on cooling of a solid surface was performed by studying the behavior of an impinging jet onto a fixed flat target. The local heat transfer coefficient distributions on a plate with a constant heat flux were computationally investigated with a normally impinging axisymmetric jet for nozzle diameter of 4.6mm at H/d = 4 and 10, with the Reynolds numbers of 10,000 and 40,000. The two-dimensional cylindrical Navier-Stokes equations were solved using a two-equation k-ε turbulence model. The finite-volume differencing scheme was used to solve the thermal and flow fields. The predicted heat transfer coefficients were compared with experimental measurements. A universal function based on the wave equation was developed and applied to the heat transfer model to improve calculated local heat transfer coefficients for short nozzle-to-plate distance (H/d = 4). The differences between H/d = 4 and 10 due to the correlation among heat transfer coefficient, kinetic energy and pressure were investigated for the impingement region. Predictions by the present model show good agreement with the experimental data.