Validation of a First Vane Platform Cooling Design

Author(s):  
Joerg Krueckels ◽  
William Colban ◽  
Michael Gritsch ◽  
Martin Schnieder

Low emission requirements for large industrial gas turbines can be achieved with flat combustor temperature profiles reducing the combustor peak temperature. As a result the heat load on the first stage vane platforms increases and platform film cooling is an important requirement. Furthermore, high lift airfoils generate stronger secondary flows including complex vortex flows over the platforms, which impacts heat transfer coefficients and film cooling. Cascade tests have been performed on a high lift profile with a platform film configuration and will be presented. The linear cascade was operated at engine representative Mach numbers. Pressure measurements are compared to design data to ensure correct operating conditions and periodicity of the cascade. The thermochromic liquid crystal measurement technique is used to obtain adiabatic film cooling effectiveness. The upstream gap (corresponding to the gap between the combustor and turbine) and the purge air exiting this gap are included in the investigations. The effect of the purge air on the recovery temperature is very strong and needs to be taken into account for the layout of the cooling scheme. The heat transfer coefficient distribution on the platform is obtained for an uncooled configuration using a transient infrared imaging technique with heat flux reconstruction. Computational fluid dynamics (CFD) assessments are used to support the validation results. Heat transfer coefficients and the effect of the purge air on adiabatic wall temperatures are compared with experimental results.

Author(s):  
J. R. Taylor

A discussion of the problems encountered in prediction of heat transfer in the turbine section of a gas turbine engine is presented. Areas of current gas turbine engine is presented. Areas of current concern to designers where knowledge is deficient or lacking are elucidated. Consideration is given to methods and problems associated with determination of heat transfer coefficients, external gas temperatures, and, where applicable, film cooling effectiveness. The paper is divided into parts dealing with turbine airfoil heat transfer, endwall heat transfer, and heat transfer in the internal cavities of cooled turbine blades. Recent literature dealing with these topics is listed.


Author(s):  
M. Cochet ◽  
W. Colban ◽  
M. Gritsch ◽  
S. Naik ◽  
M. Schnieder

Low emission requirements for heavy-duty gas turbines can be achieved with flat combustor temperature profiles, reducing the combustor peak temperature. As a result, the heat load on the first stage heat shield above the first stage blade increases. High lift airfoils cause increased thermal loading on the heat shield above the blade tip and impact the unavoidable secondary flows, including complex vortex flows. Cascade tests have been performed on a blade with a generic high lift profile and the results on the heat shield are presented. A transient thermochromic liquid crystal measurement technique was used to obtain heat transfer coefficients on the heat shield surface. Several variations of blade tip clearance were investigated, and the impact on heat transfer coefficients is shown. Computational fluid dynamics predictions are compared to the experimental data to interpret the data and validate the CFD.


2003 ◽  
Vol 125 (4) ◽  
pp. 648-657 ◽  
Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

Experimental investigations were performed to measure the detailed heat transfer coefficients and film cooling effectiveness on the squealer tip of a gas turbine blade in a five-bladed linear cascade. The blade was a two-dimensional model of a first stage gas turbine rotor blade with a profile of the GE-E3 aircraft gas turbine engine rotor blade. The test blade had a squealer (recessed) tip with a 4.22% recess. The blade model was equipped with a single row of film cooling holes on the pressure side near the tip region and the tip surface along the camber line. Hue detection based transient liquid crystals technique was used to measure heat transfer coefficients and film cooling effectiveness. All measurements were done for the three tip gap clearances of 1.0%, 1.5%, and 2.5% of blade span at the two blowing ratios of 1.0 and 2.0. The Reynolds number based on cascade exit velocity and axial chord length was 1.1×106 and the total turning angle of the blade was 97.9 deg. The overall pressure ratio was 1.2 and the inlet and exit Mach numbers were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. Results showed that the overall heat transfer coefficients increased with increasing tip gap clearance, but decreased with increasing blowing ratio. However, the overall film cooling effectiveness increased with increasing blowing ratio. Results also showed that the overall film cooling effectiveness increased but heat transfer coefficients decreased for the squealer tip when compared to the plane tip at the same tip gap clearance and blowing ratio conditions.


Author(s):  
Christian Saumweber ◽  
Achmed Schulz

A comprehensive set of generic experiments is conducted to investigate the interaction of film cooling rows. Five different film cooling configurations are considered on a large scale basis each consisting of two rows of film cooling holes in staggered arrangement. The hole pitch to diameter ratio within each row is kept constant at P/D = 4. The spacing between the rows is either x/D = 10, 20, or 30. Fanshaped holes or simple cylindrical holes with an inclination angle of 30 deg. and a hole length of 6 hole diameters are used. With a hot gas Mach number of Mam = 0.3, an engine like density ratio of ρc/ρm = 1.75, and a freestream turbulence intensity of Tu = 5.1% are established. Operating conditions are varied in terms of blowing ratio for the upstream and, independently, the downstream row in the range 0.5<M<2.0. The results illustrate the importance of considering ejection into an already film cooled boundary layer. Adiabatic film cooling effectiveness and heat transfer coefficients are significantly increased. The decay of effectiveness with streamwise distance is much less pronounced downstream of the second row primarily due to pre-cooling of the boundary layer by the first row of holes. Additionally, a comparison of measured effectiveness data with predictions according to the widely used superposition model of Sellers [11] is given for two rows of fanshaped holes.


2017 ◽  
Vol 139 (5) ◽  
Author(s):  
Stephen P. Lynch ◽  
Karen A. Thole

Turbine blade components in an engine are typically designed with gaps between parts due to manufacturing, assembly, and operational considerations. Coolant is provided to these gaps to limit the ingestion of hot combustion gases. The interaction of the gaps, their leakage flows, and the complex vortical flow at the endwall of a turbine blade can significantly impact endwall heat transfer coefficients and the effectiveness of the leakage flow in providing localized cooling. In particular, a platform gap through the passage, representing the mating interface between adjacent blades in a wheel, has been shown to have a significant effect. Other important turbine blade features present in the engine environment are nonaxisymmetric contouring of the endwall, and an upstream rim seal with a gaspath cavity, which can reduce and increase endwall vortical flow, respectively. To understand the platform gap leakage effect in this environment, measurements of endwall heat transfer, and film cooling effectiveness were performed in a scaled blade cascade with a nonaxisymmetric contour in the passage. A rim seal with a cavity, representing the overlap interface between a stator and rotor, was included upstream of the blades and a nominal purge flowrate of 0.75% of the mainstream was supplied to the rim seal. The results indicated that the endwall heat transfer coefficients increased as the platform gap net leakage increased from 0% to 0.6% of the mainstream flowrate, but net heat flux to the endwall was reduced due to high cooling effectiveness of the leakage flow.


Author(s):  
G. E. Andrews ◽  
A. A. Asere ◽  
C. I. Hussain ◽  
M. C. Mkpadi ◽  
A. Nazari

Experimental results are presented for the overall heat transfer coefficient within an impingement/effusion wall, using a transient cooling technique. This was previously used for determining the effusion hole heat transfer alone. Two impingement/effusion geometries were used with an 8 mm gap and the same impingement wall with an X/D of 11. The separate impingement and effusion short hole heat transfer coefficients were also determined. The impingement/effusion overall heat transfer was 45% and 30% higher than the impingement heat transfer alone for the two test geometries. The greater increase was for the higher pressure loss effusion wall. It was shown that the combined heat transfer was predominantly the addition of the impingement and effusion heat transfer coefficients but the interaction effects were significant and resulted in an approximately 15% deterioration in the combined heat transfer coefficient. Overall film cooling effectiveness was obtained that showed a significant improvement with the addition of the impingement cooling, but still had a major effusion film cooling contribution.


Author(s):  
Douglas N. Barlow ◽  
Yong W. Kim

An experimental investigation of film cooling on rough surfaces has been accomplished at a Reynolds number and dimensionless boundary layer momentum thickness found in current high performance first stage turbine vanes. A transient experimental method using thermochromic liquid crystals is employed to determine both local heat transfer coefficients and film cooling effectiveness values on planar rough surfaces. Two surface roughness configurations are investigated with a single row of cooling holes spaced three diameters apart and inclined 30° to the mainstream flow. The mainstream turbulence level at the point of film injection is 8.5% and the density ratio considered is approximately 1.0. The influence of roughness on the centerline film cooling effectiveness, laterally averaged film cooling effectiveness, laterally averaged heat transfer coefficients, as well as area averaged values are presented. It is found that the presence of roughness causes a decrease in the film cooling effectiveness over that of the smooth surface for the range of experimental parameters considered in this study. In addition, significant lateral smoothing in film cooling effectiveness distribution is observed for the rougher surfaces. Measured heat transfer coefficients on rough surfaces show a trend of monotonic increase with blowing ratio. However, such increase is not as great as that for the case of smooth surface.


Author(s):  
D. H. Zhang ◽  
L. Sun ◽  
Q. Y. Chen ◽  
M. Lin ◽  
M. Zeng ◽  
...  

Embedding a row of typical cylindrical holes in a transverse slot can improve the cooling performance. Rectangular slots can increase the cooling effectiveness but is at the cost of decreasing of discharge coefficients. An experiment is conducted to examine the effects of an overlying transverse inclined trench on the film cooling performance of axial holes. Four different trench configurations are tested including the baseline inclined cylindrical holes. The influence of the geometry of the upstream lip of the exit trench and the geometry of the inlet trench on cooling performance is examined. Detailed film cooling effectiveness and heat transfer coefficients are obtained separately using the steady state IR thermography technique. The discharge coefficients are also acquired to evaluate the aerodynamic performance of different hole configurations. The results show that the film cooling holes with both ends embedded in slots can provide higher film cooling effectiveness and lower heat transfer coefficients; it also can provide higher discharge coefficients whilst retaining the mechanical strength of a row of discrete holes. The cooling performance and the aerodynamic performance of the holes with both ends embedded in inclined slots are superior to the holes with only exit trenched. To a certain extent, the configuration of the upstream lip of the exit trench affects the cooling performance of the downstream of the trench. The filleting for the film hole inlet avail the improvement of the cooling effect, but not for the film hole outlet. Comparing film cooling with embedded holes to unembedded holes, the overall heat flux ratio shows that the film holes with both ends embedded in slots and filleting for the film hole inlet can produce the highest heat flux reduction.


Author(s):  
Sumanta Acharya ◽  
Huitao Yang ◽  
Srinath V. Ekkad ◽  
Chander Prakash ◽  
Ron Bunker

Numerical simulations of flow and heat transfer are presented for a GE-E3 turbine blade with a film-cooled tip. Results are presented for both a flat tip and a squealer tip. Straight-through coolant holes are considered, and the calculation domain includes the flow development in the coolant delivery tubes. Results are presented with three different tip gaps representing 1%, 1.5% and 2.5% of blade span, a blowing ratio (ratio of coolant-jet-exit velocity to average passage flow velocity) of 1, and an inlet turbulence intensity of 6.1%. On a flat tip, film coolant injection is shown to lower the local pressure ratio and alters the nature of the leakage vortex. High film cooling effectiveness and low heat transfer coefficients are obtained along the coolant trajectory; these values increase slightly with increasing tip clearances. For a squealer tip, the flow inside the squealer cavity exhibits streamwise directed flow, which alters the trajectory of the coolant jets and reduces their effectiveness.


Author(s):  
Yong W. Kim ◽  
Chad Coon ◽  
Hee-Koo Moon

Pressure-side discharge is commonly employed in turbine blades and nozzle guide vanes to keep the trailing edge metal temperatures within an allowable limit while minimizing aerodynamic penalties. Despite its widespread use, film-cooling data of the discharge slot are scarce in open literature. The objectives of the present experimental study were to measure detailed local heat transfer and film-cooling effectiveness from a 10x scale trailing-edge model of an industrial gas turbine airfoil in a low speed wind tunnel. To simulate the mainstream flow acceleration in vane and blade row passages, a linear velocity gradient was imposed using an adjustable top wall. The present work employed the composite slab quasi-steady liquid crystal method that allows measurements of local heat transfer coefficients and film-cooling effectiveness from two related tests. With this technique, the heat transfer measurement can be performed in a cold wind tunnel. The coolant-to-mainstream blowing ratio was varied between 0.25 and 1.0. The slot hydraulic diameter based Reynolds number ranged from 4,760 to 19,550. The coolant-to-mainstream density ratio was fixed at 0.95. Slot discharge coefficients were also measured with mainstream acceleration. Both local heat transfer coefficients and film-cooling effectiveness displayed a strong dependency on blowing ratio and mainstream acceleration. However, the discharge coefficients showed little dependency on the mainstream acceleration.