scholarly journals Flow Boiling in a 1.1 mm Tube With R134A: Experimental Results and Comparison With Model

Author(s):  
D. Shiferaw ◽  
T. G. Karayiannis ◽  
D. B. R. Kenning

A detailed comparison of the three-zone evaporation model, proposed by Thome et al. (2004), with experimental heat transfer results of two stainless steel tubes of internal diameter 4.26 mm and 2.01 mm using R134a fluid was presented by Shiferaw et al. (2006). In the current paper the comparison is extended to flow boiling in a 1.1 mm tube using R134a as the working fluid. Other parameters were varied in the range: mass flux 100–600 kg/m2.s; heat flux 16–150 kW/m2 and pressure 6–12 bar. The experimental results demonstrate that the heat transfer coefficient increases with heat flux and system pressure, but does not change with vapour quality when the quality is less than about 50% for low heat and mass flux values. The effect of mass flux is observed to be insignificant. For vapour quality values greater than 50% and at high heat flux values, the heat transfer coefficient does not depend on heat flux and decreases with vapour quality. This could be caused by partial dryout. The three-zone evaporation model predicts the experimental results fairly well, especially at relatively low pressure. However, the partial dryout region is highly over-predicted by the model. The sensitivity of the performance of the model to the three optimized parameters (confined bubble frequency, initial film thickness and end film thickness) and some preliminary investigation relating the critical film thickness for dryout to measured tube roughness are also discussed.

Author(s):  
M. Hamayun Maqbool ◽  
Bjo¨rn Palm ◽  
R. Khodabandeh ◽  
Rashid Ali

Experiments have been performed to investigate heat transfer in a circular vertical mini channel made of stainless steel (AISI 316) with internal diameter of 1.70 mm and a uniformly heated length of 245 mm using ammonia as working fluid. The experiments are conducted for a heat flux range of 15 to 350 kW/m2 and mass flux range of 100 to 500 kg/m2s. The effects of heat flux, mass flux and vapour quality on the heat transfer coefficient are explored in detail. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux while mass flux and vapour quality have no considerable effect. Experimental results are compared to predictive methods available in the literature for boiling heat transfer. The correlations of Cooper et al. [1] and Shah [3] are in good agreement with our experimental data.


Author(s):  
Rashid Ali ◽  
Bjo¨rn Palm ◽  
Mohammad H. Maqbool

In this paper the experimental flow boiling heat transfer results of a minichannel are presented. A series of experiments was conducted to measure the heat transfer coefficients in a minichannel made of stainless steel (AISI 316) having an internal diameter of 1.7mm and a uniformly heated length of 220mm. R134a was used as working fluid and experiments were performed at two different system pressures corresponding to saturation temperatures of 27 °C and 32 °C. Mass flux was varied from 50 kg/m2 s to 600 kg/m2 s and heat flux ranged from 2kW/m2 to 156kW/m2. The test section was heated directly using a DC power supply. The direct heating of the channel ensured uniform heating and heating was continued until dry out was reached. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux while mass flux and vapour quality have no considerable effect. Increasing the system pressure slightly enhances the heat transfer coefficient. The heat transfer coefficient is reduced as dryout is reached. It is observed that dryout phenomenon is accompanied with fluctuations and a larger standard deviation in outer wall temperatures.


2011 ◽  
Vol 133 (8) ◽  
Author(s):  
Rashid Ali ◽  
Björn Palm ◽  
Mohammad H. Maqbool

In this paper, the experimental flow boiling heat transfer results of a minichannel are presented. A series of experiments was conducted to measure the heat transfer coefficients in a minichannel made of stainless steel (AISI 316) having an internal diameter of 1.70 mm and a uniformly heated length of 220 mm. R134a was used as a working fluid, and experiments were performed at two different system pressures corresponding to saturation temperatures of 27°C and 32°C. Mass flux was varied from 50 kg/m2 s to 600 kg/m2 s, and heat flux ranged from 2 kW/m2 to 156 kW/m2. The test section was heated directly using a dc power supply. The direct heating of the channel ensured uniform heating, which was continued until dryout was reached. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux, while mass flux and vapor quality have no considerable effect. Increasing the system pressure slightly enhances the heat transfer coefficient. The heat transfer coefficient is reduced as dryout is reached. It is observed that the dryout phenomenon is accompanied with fluctuations and a larger standard deviation in outer wall temperatures.


Author(s):  
Chaobin Dang ◽  
Minxia Li ◽  
Eiji Hihara

In this study, the boiling heat transfer coefficients of carbon dioxide with a PAG-type lubricating oil entrained from 0 to 5 wt% in a horizontally placed smooth tube with an inner diameter of 2 mm were experimentally investigated under the following operating conditions: mass fluxes from 170 to 320 kg/m2s, heat fluxes from 4.5 to 36 kW/m2, and a saturation temperature of 15 °C. The results show that for a low oil concentration of approximately 0.5% to 1%, no further deterioration of the heat transfer coefficient was observed at higher oil concentrations in spite of a significant decrement of the heat transfer coefficient compared to that under an oil-free condition. The heat flux still had a positive influence on the heat transfer coefficient in low quality regions. However, no obvious influence was observed in high quality regions, which implies that nucleate boiling dominates in the low quality region whereas it is suppressed in the high quality regions. Unlike the mass flux under an oil-free condition, mass flux has a significant influence on the heat transfer coefficient, with a maximum increase of 50% in the heat transfer. On the basis of our experimental measurements of the flow boiling heat transfer of carbon dioxide under wide experimental conditions, a flow boiling heat transfer model for horizontal tubes has been proposed for a mixture of CO2 and polyalkylene glycol (PAG oil) in the pre-dryout region, with consideration of the thermodynamic properties of the mixture. The surface tension and viscosity of the mixture were particularly taken into account. New factors were introduced into the correlation to reflect the suppressive effects of the mass flux and the oil on both the nucleate boiling. It is shown that the calculated results can depict the influence of the mass flux and the heat flux on both nucleate boiling and convection boiling.


Author(s):  
K. S. Park ◽  
W. H. Choo ◽  
K. H. Bang

The flow boiling heat transfer coefficient of R-22 in small hydraulic diameter tubes has been experimentally studied. Both brass and aluminum round tubes of 1.66 mm inside diameter are used for the test section. The ranges of the major experimental parameters are 300∼600 kg/m2s of refrigerant mass flux, 10∼20 kW/m2 of the wall heat flux, 0.0∼0.9 of the inlet vapor quality. The experimental result showed that the flow boiling heat transfer coefficient in this small tubes are in the range of 2∼4 kW/m2K and it varies only by heat flux, independent of mass flux and vapor quality. It is also observed that the heat transfer coefficients in the aluminum tube are up to 50% higher than in the brass tube.


Author(s):  
Nae-Hyun Kim ◽  
Wang-Kyu Oh ◽  
Jung-Ho Ham ◽  
Do-Young Kim ◽  
Tae-Ryong Shin

Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with Dh = 1.41 mm. The test range covered mass flux from 100 to 600 kg/m2 s, heat flux from 5 to 15 kW/m2 and saturation temperature from 5°C to 15°C. The heat transfer coefficient curve shows a decreasing trend after a certain quality (critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique ‘cross-over’ of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations underpredict the low mass flux and overpredict the high mass flux data.


1998 ◽  
Vol 120 (2) ◽  
pp. 485-491 ◽  
Author(s):  
T. S. Ravigururajan

Microchannel surfaces, often machined to 20 to 1000 μm in width and depth, are employed in high-heat-flux applications. However, a large number of variables, control the two-phase flow heat transfer coefficient. The pressure, the surface heat flux, and the mass flux significantly affect the thermal transport. Experiments were conducted on a setup that was built for testing microchannel heat exchanges. The parameters considered in the study are power input: 20 to 300 W, volume flow rate: 35 to 300 ml/min, quality: 0 to 0.5, inlet subcooling: 5 to 15°C. The results indicate that the heat transfer coefficient and pressure drop are functions of the flow quality, the mass flux, and, of course, the heat flux and the related surface superheat. The heat transfer coefficient decreases from a value of 12,000 W/m2-K to 9000, W/m2-K at 80°C, when the wall superheat is increased from 10 to 80°C. The coefficient decreases by 30 percent when the exit vapor quality is increased from 0.01 to 0.65.


Author(s):  
Sudipta Saha ◽  
Rajib Mahamud ◽  
Jamil Khan ◽  
Tanvir Farouk

Phase change driven heat transfer has been the topic of interest for a significantly long time. However, in recent years on demand sweating boosted evaporation which requires substantially less amount of the liquid medium has drawn attention as a possible way of increasing/supplementing heat transfer under convective conditions where the convective heat transfer coefficient has already reached its maximum value as well as where dry cooling is a desired objective. In this study, a numerical study is conducted to obtain insight into the ‘hybrid’ system where evaporation and convection both contribute to the heat transfer effect. The system modeled consists of evaporation of thin liquid (water) film under a laminar flow condition. The mathematical model employed consists of coupled conservation equations of mass, species, momentum and energy for the convection-evaporation domain (gaseous), with only mass and energy conservation being resolved in the liquid film domain. The evaporative mass flux is obtained from a modified Hertz-Knudsen relation which is a function of liquid-vapor interface temperature and pressure. A two-dimensional rectangular domain with a pre-prescribed thin liquid water film representative of an experiment is simulated with the developed model. The thin rectangular liquid film is heated by uniform heat flux and is placed in the convection-evaporation domain with an unheated starting length. A moving boundary mesh is applied via the“Arbitrary Lagrangian-Eulerian” technique to resolve the receding liquid interface resulting from evaporation. The prescribed relative displacement of the moving interface is calculated from the net mass flux due to evaporation and is governed by the principle of mass conservation. Simulations were conducted over a range of Reynolds number, heat flux conditions and liquid film thickness. The numerical predictions indicate that under convective-evaporative conditions the overall heat transfer coefficient increases significantly (∼factor of a five) in comparison to the purely forced convection scenario. An increase in the heat transfer coefficient is observed with Reynolds number and vice versa for film thickness. A critical Reynolds number is identified beyond which the heat transfer coefficient does not continue to increase significantly rather tends to plateau out.


Author(s):  
Ronald Akbar ◽  
Jong Taek Oh ◽  
Agus Sunjarianto Pamitran

Various experiments have been conducted on the heat transfer coefficient of two-phase flow boiling in mini channel tubes. In addition to obtaining data on the heat transfer coefficients through experiments, many researchers have also compared their experimental data using existing correlations. This research aims to determine the characteristics of the heat transfer coefficient of refrigerant R290 from the data used by processing and knowing the best heat transfer coefficient correlation in predicting the experimental data so that the results are expected to be a reference for designing a heat exchanger or for further research. The experimental data predicted is the two-phase flow boiling in a horizontal tube 3 mm diameter, with the mass flux of 50-180 kg/m2s, heat flux of 5-20 kW/m2, saturation temperature of 0-11 °C, and vapor quality of 0-1. The correlation used in this research is based on the asymptotic flow model, where the model is a combination of the nucleate and convective flow boiling mechanisms. The results show an effect of mass flux and heat flux on the experimental heat transfer coefficient and the predicted R290 heat transfer coefficient with asymptotic correlations had a good and similar result to the experimental data.