Two-Phase Flow Induced Vibration of an Array of Tubes Preferentially Flexible in the Flow Direction

Author(s):  
R. Violette ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Tests were done to study the fluidelastic instability of a cluster of seven cylinders much more flexible in the flow direction than in the lift direction. The array configuration is rotated triangular with a pitch to diameter ratio of 1.5. The array was subjected to two-phase (air-water) cross flow. Cylinder natural frequencies of 14 and 28 Hz were tested. Fluidelastic instabilities were observed at 65, 80, 90 and 95% void fraction albeit at a somewhat higher flow velocity than that expected for axisymetrically flexible arrays. These results and additional wind tunnel results are compared to existing data on fluidelastic instability.

1994 ◽  
Vol 116 (3) ◽  
pp. 233-253 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor

Two-phase flow exists in many industrial components. To avoid costly vibration problems, sound technology in the area of two-phase flow-induced vibration is required. This paper is an overview of the principal mechanisms governing vibration in two-phase flow. Dynamic parameters such as hydrodynamic mass and damping are discussed. Vibration excitation mechanisms in axial flow are outlined. These include fluidelastic instability, phase-change noise, and random excitation. Vibration excitation mechanisms in cross-flow, such as fluidelastic instability, periodic wake shedding, and random excitation, are reviewed.


Author(s):  
T. F. Joly ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Tests were done to study the effect of angle of attack on the fluidelastic instability of a fully flexible tube bundle subjected to two-phase (Air-Water) cross-flow. A test array having nineteen flexible tubes in a rotated triangular configuration with a pitch-to-diameter ratio of 1.5 was tested. Four different angles of attack ranging for 0 degree (inline flexibility) through 30 and 60 degrees to 90 degrees (transverse flexibility) were studied. For each angle of attack several homogeneous void fractions have been tested (70%, 80%, 90%, and 95%). Stability test results show that the angle of attack strongly affect the tube bundle dynamic behavior. The different mechanisms underlying the fluidelastic instability are highlighted and the results compared to existing data on fluidelastic instability.


2005 ◽  
Vol 128 (1) ◽  
pp. 148-159 ◽  
Author(s):  
R. Violette ◽  
M. J. Pettigrew ◽  
N. W. Mureithi

Almost all the available data about fluidelastic instability of heat exchanger tube bundles concerns tubes that are axisymmetrically flexible. In those cases, the instability is found to be mostly in the direction transverse to the flow. Thus, the direction parallel to the flow has raised less concern in terms of bundle stability. However, the flat bar supports used in steam generator for preventing U-tube vibration may not be as effective in the in-plane direction than in the out-of-plane direction. The possibility that fluidelastic instability can develop in the flow direction must then be assessed. In the present work, tests were done to study the fluidelastic instability of a cluster of seven tubes much more flexible in the flow direction than in the lift direction. The array configuration is rotated triangular with a pitch to diameter ratio of 1.5. The array was subjected to two-phase (air-water) cross flow. Fluidelastic instability was observed when the flexible tubes were located at the center of the test section and also when the seven flexible tubes were placed over two adjacent columns. No instability was found for a single flexible tube in a rigid array, nor for the case where the seven flexible tubes were placed in a single column. Tests were also done with tubes that are axisymmetrically flexible for comparison purposes. It was found that fluidelastic instability occurs at higher velocities when the tubes are flexible only in the flow direction. These results and additional wind tunnel results are compared to existing data on fluidelastic instability. Two-phase flow damping results are also presented in this paper.


Author(s):  
Tomomichi Nakamura ◽  
Shinichiro Hagiwara ◽  
Joji Yamada ◽  
Kenji Usuki

In-flow instability of tube arrays is a recent major issue in heat exchanger design since the event at a nuclear power plant in California [1]. In our previous tests [2], the effect of the pitch-to-diameter ratio on fluidelastic instability in triangular arrays is reported. This is one of the present major issues in the nuclear industry. However, tube arrays in some heat exchangers are arranged as a square array configuration. Then, it is important to study the in-flow instability on the case of square arrays. The in-flow fluidelastic instability of square arrays is investigated in this report. It was easy to observe the in-flow instability of triangular arrays, but not for square arrays. The pitch-to-diameter ratio, P/D, is changed from 1.2 to 1.5. In-flow fluidelastic instability was not observed in the in-flow direction. Contrarily, the transverse instability is observed in all cases including the case of a single flexible cylinder. The test results are finally reported including the comparison with the triangular arrays.


Author(s):  
Deepanjan Mitra ◽  
Vijay K. Dhir ◽  
Ivan Catton

In the past, fluid-elastic instability in two-phase flow has been largely investigated with air-water flow. In this work, new experiments are conducted in air-water cross-flow with a fully flexible 5 × 3 normal square array having pitch-to-diameter ratio of 1.4. The tubes have a diameter of 0.016 m and a length of 0.21 m. The vibrations are measured using strain gages installed on piano wires used to suspend the tubes. Experiments are carried out for void fractions from 0%–30%. A comparison of the results of the current tests with previous experiments conducted in air-water cross-flow shows that instability occurs earlier in a fully flexible array as compared to a flexible tube surrounded by rigid tubes in an array. An attempt is made to separate out the effects of structural parameters of three different experimental datasets by replotting the instability criterion by incorporating the instability constant K, in the reduced velocity parameter.


Author(s):  
H. Senez ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Two-phase cross flow exists in many shell-and-tube heat exchangers. Flow-induced vibration excitation forces can cause tube motion that will result in long-term fretting wear or fatigue. Detailed flow and vibration excitation force measurements in tube bundles subjected to two-phase cross flow are required to understand the underlying vibration excitation mechanisms. Studies on this subject have already been done, providing results on flow regimes, fluidelastic instabilities, and turbulence-induced vibration. The spectrum of turbulence-induced forces has usually been expected to be similar to that in single-phase flow. However, a recent study, using tubes with a diameter larger than that in a real steam generator, showed the existence of significant quasi-periodic forces in two-phase flow. An experimental program was undertaken with a rotated-triangular array of cylinders subjected to air-water cross-flow, to simulate two-phase mixtures. The tube bundle here has the same geometry as that of a real steam generator. The quasi-periodic forces have now also been observed in this tube bundle. The present work aims to understand turbulence-induced forces acting on the tube bundle, providing results on drag and lift force spectra and their behaviour according to flow parameters, and describing their correlations. Detailed experimental test results are presented in this paper. Comparison is also made with previous measurements with larger diameter tubes. The present results suggest that quasi-periodic fluid forces are not uncommon in tube arrays subjected to two-phase cross-flow.


1995 ◽  
Vol 117 (4) ◽  
pp. 321-329 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
J. H. Jong ◽  
I. G. Currie

Two-phase cross-flow exists in many shell-and-tube heat exchangers. The U-bend region of nuclear steam generators is a prime example. Testing in two-phase flow simulated by air-water provides useful results inexpensively. However, two-phase flow parameters, in particular surface tension and density ratio, are considerably different in air-water than in steam-water. A reasonable compromise is testing in liquid-vapor Freon, which is much closer to steam-water while much simpler experimentally. This paper presents the first results of a series of tests on the vibration behavior of tube bundles subjected to two-phase Freon cross-flow. A rotated triangular tube bundle of tube-to-diameter ratio of 1.5 was tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, and damping were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability. Generally, random turbulence excitation forces are much lower in Freon than in air-water. Damping is very dependent on void fraction, as expected.


2004 ◽  
Vol 126 (4) ◽  
pp. 523-533 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor

Two-phase flow exists in many shell-and-tube heat exchangers such as condensers, evaporators, and nuclear steam generators. Some knowledge on tube damping mechanisms is required to avoid flow-induced vibration problems. This paper outlines the development of a semi-empirical model to formulate damping of heat exchanger tube bundles in two-phase cross flow. The formulation is based on information available in the literature and on the results of recently completed experiments. The compilation of a database and the formulation of a design guideline are outlined in this paper. The effects of several parameters such as flow velocity, void fraction, confinement, flow regime and fluid properties are discussed. These parameters are taken into consideration in the formulation of a practical design guideline.


Author(s):  
Paul Feenstra ◽  
Teguewinde Sawadogo ◽  
Bruce Smith ◽  
Victor Janzen ◽  
Helen Cothron

The tubes in the U-bend region of a recirculating type of nuclear steam generator are subjected to cross-flow of a two-phase mixture of steam and water. There is a concern that these tubes may experience flow-induced vibration, including the damaging effects of fluidelastic instability. This paper presents an update and results from a series of flow-induced vibration experiments performed by Canadian Nuclear Laboratories for the Electric Power Research Institute (EPRI) using the Multi-Span U-Bend test rig. In the present experiments, the main focus was to investigate fluidelastic instability of the U-tubes subjected to a cross-flow of air. The tube bundle is made of 22 U-tubes of 0.5 in (12.7 mm) diameter, arranged in a rotated triangular configuration with a pitch-over-diameter ratio of 1.5. The test rig could be equipped with variable clearance flat bar supports at two different locations to investigate a variety of tube and support configurations. The primary purpose of the overall project is to study the effect of flat bar supports on ‘in plane’ (‘streamwise’) instability in a U-tube bundle with realistic tube-to-support clearances or preloads, and eventually in two-phase flow conditions. Initially, the test rig was designed for tests in air-flow using an industrial air blower. Tests with two-phase Freon refrigerant (R-134a) will follow. This paper describes the test rig, experimental setup, and the challenges presented by simulating an accurate representation of current steam generator designs. Results from the first series of tests in air flow are described.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Paul Feenstra ◽  
David S. Weaver ◽  
Tomomichi Nakamura

Laboratory experiments were conducted to determine the flow-induced vibration response and fluidelastic instability threshold of model heat exchanger tube bundles subjected to a cross-flow of refrigerant 11. Tube bundles were specially built with tubes cantilever-mounted on rectangular brass support bars so that the stiffness in the streamwise direction was about double that in the transverse direction. This was designed to simulate the tube dynamics in the U-bend region of a recirculating-type nuclear steam generator. Three model tube bundles were studied, one with a pitch ratio of 1.49 and two with a smaller pitch ratio of 1.33. The primary intent of the research was to improve our understanding of the flow-induced vibrations of heat exchanger tube arrays subjected to two-phase cross-flow. Of particular concern was to compare the effect of the asymmetric stiffness on the fluidelastic stability threshold with that of axisymmetric stiffness arrays tested most prominently in literature. The experimental results are analyzed and compared with existing data from literature using various definitions of two-phase fluid parameters. The fluidelastic stability thresholds of the present study agree well with results from previous studies for single-phase flow. In two-phase flow, the comparison of the stability data depends on the definition of two-phase flow velocity.


Sign in / Sign up

Export Citation Format

Share Document