Analysis of ASME Class 3 Buried HDPE Piping Systems Related to Code Case N-755-1

Author(s):  
Young Seok Kim ◽  
Jung Kwang Yoon ◽  
Young Ho Kim

This paper proposes an analysis method for Section III, Division 1, Class 3 buried High Density polyethylene (HDPE) piping system in the nuclear power plants (NPP). Although HDPE pipe would yield at high temperature (limited to 140°F), it may be suitable for the areas prone to earthquakes; owing to its comparable ductility and flexibility. Thus, the buried HDPE piping may be applicable for the safety related Essential Service Water (ESW) system in the NPPs. Despite some limitations to buried HDPE piping, the piping could be designed based on ASME Code Case [1]. Generally, codes and standards including ASME Code Case [1] do not provide load combinations for the design of both buried steel piping and HDPE piping. Meanwhile, EPRI Report [4] provides load combinations including thermal expansion effects and seismic loads with detailed seismic criteria for polyethylene pipe. In this paper, load cases and load combinations for buried HDPE piping are suggested for implementation of reference documents and a buried HDPE piping system is analyzed referring to EPRI Report [4] to evaluate stress, force, and moment using a piping stress analysis program. Additionally, this paper will recommend the design procedure in accordance with ASME Code Case [1] using an example of buried HDPE piping analysis. An investigation of soil spring coefficients and the design considerations for hydrostatic tests are suggested for the enhanced analysis of buried HDPE piping.

Author(s):  
Prabhat Krishnaswamy ◽  
Eric M. Focht ◽  
Do-Jun Shim ◽  
Tao Zhang

The ASME Boiler and Pressure Vessel Code Committee (BPVC) has recently published Code Case N-755 that describes the requirements for the use of Polyethylene (PE) pipe for the construction of Section III, Division 1 Class 3 buried piping systems for service water applications in nuclear power plants. The code case was developed by Special Working Group–Polyethylene Pipe (SWG-PP) within Section III (Design) of the BPVC. This paper provides a critical review of the design requirements described in CC N-755 from pressure boundary integrity considerations. The various technical issues that need to be addressed for safety-critical PE piping are discussed in this paper. Specifically, the premise of allowing defects in pipe that are 10% of the wall thickness has been reviewed especially for cases involving large diameter piping [> 304.8 mm (12 inches)] that is to be operated at elevated temperatures as high as 60°C (140°F). One of the common modes of failure in PE piping under sustained internal pressure is due to slow crack growth (SCG) from manufacturing or installation defects in the pipe wall. The effect of pipe diameter and stresses on the crack driving force for a 10% deep flaw is calculated for comparison with the material resistance to SCG at elevated temperatures.


Author(s):  
Bruce A. Young ◽  
Sang-Min Lee ◽  
Paul M. Scott

As a means of demonstrating compliance with the United States Code of Federal Regulations 10CFR50 Appendix A, General Design Criterion 4 (GDC-4) requirement that primary piping systems for nuclear power plants exhibit an extremely low probability of rupture, probabilistic fracture mechanics (PFM) software has become increasingly popular. One of these PFM codes for nuclear piping is Pro-LOCA which has been under development over the last decade. Currently, Pro-LOCA is being enhanced under an international cooperative program entitled PARTRIDGE-II (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE - Phase II). This paper focuses on the use of a pre-defined set of base-case inputs along with prescribed variation in some of those inputs to determine a comparative set of sensitivity analyses results. The benchmarking case was a circumferential Primary Water Stress Corrosion Crack (PWSCC) in a typical PWR primary piping system. The effects of normal operating loads, temperature, leak detection, inspection frequency and quality, and mitigation strategies on the rupture probability were studied. The results of this study will be compared to the results of other PFM codes using the same base-case and variations in inputs. This study was conducted using Pro-LOCA version 4.1.9.


Author(s):  
Se´bastien Caillaud ◽  
Rene´-Jean Gibert ◽  
Pierre Moussou ◽  
Joe¨l Cohen ◽  
Fabien Millet

A piping system of French nuclear power plants displays large amplitude vibrations in particular flow regimes. These troubles are attributed to cavitation generated by single-hole orifices in depressurized flow regimes. Real scale experiments on high pressure test rigs and on-site tests are then conducted to explain the observed phenomenon and to find a solution to reduce pipe vibrations. The first objective of the present paper is to analyze cavitation-induced vibrations in the single-hole orifice. It is then shown that the orifice operates in choked flow with supercavitation, which is characterized by a large unstable vapor pocket. One way to reduce pipe vibrations consists in suppressing the orifices and in modifying the control valves. Three technologies involving a standard trim and anti-cavitation trims are tested. The second objective of the paper is to analyze cavitation-induced vibrations in globe-style valves. Cavitating valves operate in choked flow as the orifice. Nevertheless, no vapor pocket appears inside the pipe and no unstable phenomenon is observed. The comparison with an anti-cavitation solution shows that cavitation reduction has no impact on low frequency excitation. The effect of cavitation reduction on pipe vibrations, which involve essentially low frequencies, is then limited and the first solution, which is the standard globe-style valve installed on-site, leads to acceptable pipe vibrations. Finally, this case study may have consequences on the design of piping systems. First, cavitation in orifices must be limited. Choked flow in orifices may lead to supercavitation, which is here a damaging and unstable phenomenon. The second conclusion is that the reduction of cavitation in globe-style valve in choked flow does not reduce pipe vibrations. The issue is then to limit cavitation erosion of valve trims.


Author(s):  
S. Kalyanam ◽  
D.-J. Shim ◽  
P. Krishnaswamy ◽  
Y. Hioe

HDPE pipes are considered by the nuclear industry as a potential replacement option to currently employed metallic piping for service-water applications. The pipes operate under high temperatures and pressures. Hence HDPE pipes are being evaluated from perspective of design, operation, and service life requirements before routine installation in nuclear power plants. Various articles of the ASME Code Case N-755 consider the different aspects related to material performance, design, fabrication, and examination of HDPE materials. Amongst them, the material resistance (part of Article 2000) to the slow crack growth (SCG) from flaws/cracks present in HDPE pipe materials is an important concern. Experimental investigations have revealed that there is a marked difference (almost three orders less) in the time to failure when the notch/flaw is in the butt-fusion joint, as opposed to when the notch/flaw is located in the parent HDPE material. As part of ongoing studies, the material resistance to SCG was investigated earlier for unimodal materials. The current study investigated the SCG in parent and butt-fusion joint materials of bimodal HDPE (PE4710) pipe materials acquired from two different manufacturers. The various stages of the specimen deformation and failure during the creep test are characterized. Detailed photographs of the specimen side-surface were used to monitor the specimen damage accumulation and SCG. The SCG was tested using a large specimen (large creep frame) as well as using a smaller size specimen (PENT frame) and the results were compared. Further, the effect of polymer orientation or microstructure in the bimodal HDPE pipe on the SCG was studied using specimens with axial and circumferential notch orientations in the parent pipe material.


Author(s):  
Nicolas d’Udekem ◽  
Philippe Art ◽  
Jacques Grisel

Nowadays, the usefulness of RTR (Reinforced Thermosetting Resin) for pressure retaining equipment does not need further proof: they are lightweight, strong, with low thermal elongation and highly corrosion resistant. The use of RTR piping makes all sense for piping systems circulating raw water such as sea water at moderate pressure and temperature for plants cooling. However, this material is rarely used for safety related cooling systems in nuclear power plants. In Belgium, Electrabel and Tractebel have chosen to replace the existing carbon steel pipes of the raw water system by GRE (Glassfiber Reinforced Epoxy) pipes, in accordance with the Authorized Inspection Agency, applying the ASME Code Case (CC) N-155-2 defining the specifications and requirements for the use of RTR pipes, fittings and flanges. After a challenging qualification process, Class 3 GRE pipes are now installed and operating for raw water cooling systems in two Belgian nuclear units and will soon be installed in a third one. The paper will address the followed qualification processes and the implementation steps applied by Electrabel/Tractebel and relate the overcome obstacles encountered during manufacturing, erection and commissioning of Class 3 GRE piping in order to ensure quality, reliability and traceability required for safety equipment in nuclear power plants.


Author(s):  
Kei Kobayashi ◽  
Takashi Satoh ◽  
Nobuyuki Kojima ◽  
Kiyoshi Hattori ◽  
Masaki Nakagawa ◽  
...  

The present design damping constants for nuclear power plant (NPP)’s piping system in Japan were developed through discussion among expert researchers, electric utilities and power plant manufactures. They are standardized in “Technical guidelines for seismic design of Nuclear Power Plants” (JEAG 4601-1991 Supplemental Edition). But some of the damping constants are too conservative because of a lack of experimental data. To improve this excessive conservatism, piping systems supported by U-bolts were chosen and U-bolt support element test and piping model excitation test were performed to obtain proper damping constants. The damping mechanism consists of damping due to piping materials, damping due to fluid interaction, damping due to plastic deformation of piping and supports, and damping due to friction and collision between piping and supports. Because the damping due to friction and collision was considered to be dominant, we focused our effort on formulating these phenomena by a physical model. The validity of damping estimation method was confirmed by comparing data that was obtained from the elemental tests and the actual scale piping model test. New design damping constants were decided from the damping estimations for piping systems in an actual plant. From now on, we will use the new design damping constants for U-bolt support piping systems, which were proposed from this study, as a standard in the Japanese piping seismic design.


Author(s):  
Douglas Munson ◽  
Timothy M. Adams ◽  
Shawn Nickholds

For corroded piping in low temperature systems, such as service water systems in nuclear power plants, replacement of carbon steel pipe with high density polyethylene (HDPE) pipe is a cost-effective solution. HDPE pipe can be installed at much lower labor costs than carbon steel pipe, and HDPE pipe has a much greater resistance to corrosion. This paper presents the results of the seismic testing of selected vent and drain configurations. This testing was conducted to provide proof of the conceptual design of HDPE vent and drain valve configurations. A total of eight representative models of HDPE vent and drain assemblies were designed. The models were subjected to seismic SQURTS spectral acceleration up to maximum shake table limits. The test configurations were then checked for leakage and operability of the valves. The results for these tests, along with the test configurations, are presented. Also presented are the acceleration data observed at various points on the test specimens.


Author(s):  
Harvey Svetlik

30 years ago, steel pipe was the standard in the ASME code for raw water supply and raw water handling at Nuclear Power Plants. At some power plants, despite best efforts, that steel pipe has suffered intermittent leakage from external and severe MIC internal corrosion. Additionally, internal tuberculation and mineral build-up has severely constricted flow in other pipelines. Advanced, engineering pipe-grade polyethylene pipe has been extruded and used in some nuclear power plants as the effective method to eliminate corrosion and tuberculation of raw water system pipelines. Implementing the change to earth-quake tolerant polyethylene pipelines has resulted in decreased maintenance, increased system reliability, and improved plant longevity. The expectation is that the advanced polyethylene will provide continuous service up to 100 years from initial installation, with a very low statistical probability of any pressure rupture during its service life. Herein discussed is the engineering grade of polyethylene material, its design basis, the conversion of extruded heavy-wall pipe (Picture 1) into fabricated components, and the final production of fully pressure-rated, fabricated pipe fittings with wall thickness of up to 5-inches. Fabrication pictures 1 to 12 are included.


1999 ◽  
Vol 121 (1) ◽  
pp. 30-36 ◽  
Author(s):  
H. Shibata

This paper deals with the role of proving tests and a large shaking test facility for equipment and piping systems in conjunction with the development of aseismic design in the field of mechanical engineering, especially for nuclear power plants in Japan. To avoid seismic disaster and damage of equipment and piping systems as well as liquid storages, we had to differentiate the seismic design procedure in mechanical engineering from that for building and civil engineering structures. For this process, the dynamic analysis in this field is more significant than for other fields. The author has been trying to develop aseismic design since the design stage of the first nuclear power plant in 1958 based on his experience as a specialist of mechanical vibration. In the early 1970s, shaking tables were developed for this purpose in Japan. The largest one in Japan is a 1000-ton 2-D table. After the 1995 Kobe earthquake, we have been developing a new 1200-ton 3-D shaking table. In the paper, the author discusses the necessity of such a facility and presents a new concept of a numerical shaking table.


Author(s):  
Adel N. Haddad

Originally introduced in the 1990s, bimodal HDPE, pipe resins are still finding new niches today, including even nuclear power plants. HDPE pipe grades are used to make strong, corrosion resistant and durable pipes. High density polyethylene, PE 4710, is the material of choice of the nuclear industry for the Safety Related Service Water System. This grade of polymer is characterized by a Hydrostatic Design Basis (HDB) of 1600 psi at 73 °F and 1000 psi at 140 °F. Additionally bimodal high density PE 4710 grades display >2000 hours slow crack growth resistance, or PENT. HD PE 4710 grades are easy to extrude into large diameter pipes; fabricate into fitting and mitered elbows and install in industrial settings. The scope of this paper is to describe the bimodal technology which produces HDPE pipe grade polymer; the USA practices of post reactor melt blending of natural resin compound with black masterbatch; and the attributes of such compound and its conformance to the nuclear industry’s Safety Related Service Water System.