Volume 8: Seismic Engineering
Latest Publications


TOTAL DOCUMENTS

29
(FIVE YEARS 0)

H-INDEX

1
(FIVE YEARS 0)

Published By American Society Of Mechanical Engineers

9780791855072

Author(s):  
Tomohiro Ito ◽  
Atsuhiko Shintani ◽  
Chihiro Nakagawa

Perforated plates are used in many mechanical structures in thermal power plants, nuclear power plants, or chemical plants etc. Cylindrical structures made by the perforated plates are also found in many places. However, vibration characteristics of the structures made by perforated plates are not fully clarified, especially for the structures immersed in liquid. The stiffness of the structures becomes smaller than that of ones made by simple plates with no holes, while the mass of the structures also becomes smaller. According to the balance between the stiffness reduction and mass reduction, natural frequencies will be decided. Moreover, added mass and added damping effects are very large in liquid, and are thought to largely change due to holes. In this study, as a fundamental step, a perforated plate is treated. The vibration characteristics such as natural frequency and damping ratio are studied for various hole numbers or various opening ratios by both numerical simulations and simple test models. Vibration tests are conducted in liquid as well as in air.


Author(s):  
Masaki Mitsuya ◽  
Takashi Sakanoue ◽  
Hiroyuki Motohashi

During seismic events, buried pipelines are subjected to deformation by seismic ground motion. In such cases, it is important to ensure the integrity of the pipeline. Both beam-mode and shell-mode buckling may occur in the event of compressive loading induced by seismic ground motion. In this study, the beam-mode buckling of a buried pipeline that occurred after the 2007 Niigataken Chuetsu-oki earthquake in Japan is investigated. A simple formula for estimating the critical strain, which is the strain at the peak load, is derived, and the formula is validated by finite-element analysis. In the formula, the critical strain increases with the pipeline diameter and hardness of the surrounding soil. By comparing the critical strain derived in this study for beam-mode buckling with the critical strain derived in a past study for shell-mode buckling, the formula facilitates the selection of the mode to be considered for evaluating the earthquake resistance of a pipeline. In addition to the critical strain, a method to estimate the deformation caused by seismic ground motion is proposed; the method can be used to evaluate the earthquake resistance of buried pipelines. This method uses finite-element analyses, and the soil–pipe interaction is considered. This method is used to reproduce the actual beam-mode buckling observed after the Niigataken Chuetsu-oki earthquake, and the earthquake resistance of a buried pipeline with general properties is evaluated as an example.


Author(s):  
Tao Zhang ◽  
Frederick W. Brust ◽  
Gery Wilkowski ◽  
Heqin Xu ◽  
Alfredo A. Betervide ◽  
...  

The Atucha II nuclear power plant is a unique pressurized heavy water reactor (PHWR) being constructed in Argentina. The original plant design was by Kraftwerk Union (KWU) in the 1970’s using the German methodology of break preclusion. The plant construction was halted for several decades, but a recent need for power was the driver for restarting the construction. The US NRC developed leak-before-break (LBB) procedures in draft Standard Review Plan (SRP) 3.6.3 for the purpose of eliminating the need to design for dynamic effects that allowed the elimination of pipe whip restraints and jet impingement shields. This SRP was originally written in 1987 with a modest revision in 2005. The United States Nuclear Regulatory Commission (US NRC) is currently developing a draft Regulatory Guide on what is called the Transition Break Size (TBS). However, modeling crack pipe response in large complex primary piping systems under seismic loading is a difficult analysis challenge due to many factors. The initial published work on the seismic evaluations for the Atucha II plant showed that even with a seismic event with the amplitudes corresponding to the amplitudes for an event with a probability of 1e−6 per year, that a Double-Ended Guillotine Break (DEGB) was pragmatically impossible due to the incredibly high leakage rates and total loss of make-up water inventory. The critical circumferential through-wall flaw size in that case was 94-percent of the circumference. This paper discusses further efforts to show how much higher the applied accelerations would have to be to cause a DEGB for an initial circumferential through-wall crack that was 33 percent around the circumference. This flaw length would also be easily detected by leakage and loss of make-up water inventory. These analyses showed that the applied seismic peak-ground accelerations had to exceed 25 g’s for the case of this through-wall-crack to become a DEGB during a single seismic loading event. This is a factor of 80 times higher than the 1e−6 seismic event accelerations, or 240 times higher than the safe shutdown earthquake (SSE) accelerations.


Author(s):  
Maria Vathi ◽  
Spyros A. Karamanos

Unanchored liquid storage tanks under strong earthquake loading tend to uplift. In the present study, the effects of base uplifting on the seismic response of unanchored tanks are presented with emphasis on elephant’s foot buckling, base plate strength and shell-to-base connection capacity. Towards this purpose, base uplifting mechanics is analyzed through a detailed simulation of the tank using non-linear finite elements, and a static pushover analysis is conducted that considers the hydrodynamic pressure distribution due to seismic loading on the tank wall and the base plate. The uplifting provisions from EN 1998-4 and API 650 Appendix E standards are briefly described. Numerical results for a typical 27.8-meter-diameter steel tank are compared with the above design provisions.


Author(s):  
Toshihiko Asami ◽  
Yasutaka Yokota ◽  
Tomohiko Ise ◽  
Itsuro Honda ◽  
Hiroya Sakamoto

This paper proposes a simple expression for calculating the restoring and damping forces of an air spring equipped with a small tube. Air springs are commonly used in railway vehicles, automobiles, and various vibration isolators. The air spring used in this study consists of two tanks connected by a long tube. Using a tube instead of an orifice enables flexibility in the arrangement of the two tanks. In addition, this makes it possible to manufacture a thin air spring. The oscillating system, which consists of a single mass supported by this type of air spring, is a single-degree-of-freedom (SDOF) system. However, it has two resonance points for a reason that had been unknown for a long period of time. In this paper, we explain why the SDOF system has two resonance points. After that, assuming that the vibration is small and the flow through the tube is laminar, we derive the spring constant and damping coefficient of an air spring subjected to a simple harmonic motion. Then, we calculate the frequency response curves for the system and compare the calculated results with the experimental values. According to the experiment, there is a remarkable amplitude dependency in this type of air spring, so the frequency response curves for the system change with the magnitude of the input amplitude. It becomes clear that the calculation results are in agreement with the limit value when the input amplitude approaches zero.


Author(s):  
Douglas Munson ◽  
Timothy M. Adams ◽  
Shawn Nickholds

For corroded piping in low temperature systems, such as service water systems in nuclear power plants, replacement of carbon steel pipe with high density polyethylene (HDPE) pipe is a cost-effective solution. HDPE pipe can be installed at much lower labor costs than carbon steel pipe, and HDPE pipe has a much greater resistance to corrosion. This paper presents the results of the seismic testing of selected vent and drain configurations. This testing was conducted to provide proof of the conceptual design of HDPE vent and drain valve configurations. A total of eight representative models of HDPE vent and drain assemblies were designed. The models were subjected to seismic SQURTS spectral acceleration up to maximum shake table limits. The test configurations were then checked for leakage and operability of the valves. The results for these tests, along with the test configurations, are presented. Also presented are the acceleration data observed at various points on the test specimens.


Author(s):  
Se-Kwon Jung ◽  
Joseph Harrold ◽  
Nawar Alchaar

Due to the increased size and complexity of large-scale commercial and industrial structures, it is increasingly challenging to manage key engineering data including analysis and design results of these structures. This paper presents a novel approach of using large-scale database systems as a means to gather, organize and manage key analysis and design results of a large-scale structure. Specifically, this paper describes in detail the development process of the backend database management system (DBMS) for the U.S. EPR™ Standard Nuclear Power Plant (NPP) Nuclear Island (NI) structures. The database system consists of three parent database tables to represent three representative groups of load combinations applicable to the U.S. EPR™ Standard NPP. Inheriting all characteristics of an applicable parent table, a primary child table in the database system represents a particular U.S. EPR™ NI Safety-Related structure in its entirety while a secondary child table a group of slabs or walls of the structure. Each secondary table is comprised of database fields that are representative of various structural demands, section capacities, reinforcing ratios, and demand-to-capacity ratios for three reinforced concrete design conditions (i.e., combined axial force and bending design, in-plane shear design, and out-of-plane shear design). The complete database system with fully populated tables is a central repository where all analysis and design results for the U.S. EPR™ NI Common Basemat structures are stored and sorted. To facilitate data queries from the developed backend database system, this paper introduces a user-friendly frontend interface program developed using Visual Basic Application (VBA) with Excel. Potential benefits of the developed database system are demonstrated with simple application examples involving simple data queries only followed by complex engineering tasks that require a more advanced form of data queries.


Author(s):  
Osamu Furuya ◽  
Kengo Goda ◽  
Kenta Ishihana

The seismic safety should be constantly considered for mechanical, architectural and civil structures in Japan where is one of severe quake-prone countries in the world. The aseismic construction, seismically isolated structure and response control structure have been applied to the several structures for upgrading of seismic safety, and then the design technique for large scale structure in the current situation is close to standard range in recent years. However, the quake-proof technique for the smaller scale structure such as a detached house, server rack and art and craft has not yet been in the development stage until now, and especially there is a problem in the damping element in the practical use stage because the downsizing of damping element is often difficult to be adapted to design specification such as a performance, a cost, a mechanism and so on for comparatively small structure. In this study, the urethane material has been developed to use as a damping element in the response control device. The newly urethane gel material is compounded to become the characteristic that a spring element in the material to minimize the effect against the structural rigidity. This paper describes the efficiency of newly developed urethane gel material as a damping element is considered from several material characteristic evaluations and basic mechanical characteristic investigations.


Author(s):  
C. S. Tsai ◽  
H. C. Su ◽  
T. C. Chiang ◽  
Y. C. Lin

Many countries have gradually adopted the buckling-restrained brace (BRB) for preventing structural damage during earthquakes since its introduction in the 1970s. In this study, we propose an all-steel BRB called the multi-curve buckling-restrained brace (MC-BRB) to overcome the shortcomings of traditional BRBs that use mortar encased in a steel tube. This new BRB consists of double core plates, each with multiple neck portions that form multiple energy dissipation segments, enlarged segments, lateral support elements, and constraining elements that are designed to prevent the BRB from buckling. The enlarged segment located in the middle of the core plate can be connected to the lateral support and constraining elements to increase buckling strength and prevent the lateral support and constraining elements from sliding during earthquakes. The lateral support elements can be windowed to allow quality control checks to be performed and the condition of the core plate to be monitored after an earthquake. In this study, a huge-scale component test with an axial load of 14000 KN in the core plates was carried out to investigate the behavior of the new BRB and its capabilities for seismic mitigation. A comparison of the experimental results and theoretical calculations indicate that the all-steel MC-BRB possesses a stable and predictable mechanical behavior under cyclic loadings.


Sign in / Sign up

Export Citation Format

Share Document