Acoustical Characteristics of Single and Two-Phase Horizontal Pipe Flow Through an Orifice

Author(s):  
S. P. C. Belfroid

In this work, the acoustic effects of horizontal air-water flow through an orifice are investigated experimentally. Single phase flow (air) and two-phase flow (air and water) tests are performed for two sets of orifices. One set of straight edged and one set of upstream rounded orifices. For each set, the diameters of the orifices were 2, 5, and 10mm, with a thickness of 5 mm. The two-phase flow is generated by injecting water at a rate of 0 to 40 g/s to air in a pipe with diameter of 25 mm. The air rate is fixed in the range from 5.8 to 14 g/s, where the upstream pressure varies from 1.5 to 4 bar at ambient temperature. Unsteady pressure fluctuations are recorded at two upstream and two downstream position. The valve noise standard NEN-EN-IEC (60534-8-3, 2011) for dry gas is assessed by means of experimental data in dry conditions at fixed air mass flow rate. Predictions of sound power spectra by means of the standard are found to be more accurate compared to those obtained following Reethof & Ward (1986), also in conditions of a choked orifice. In case of multiphase flow already at very low liquid fractions of much less than 1%, the standard is no longer valid. The frequency spectrum is no longer determined by the jet noise but starts to be dominated by low frequency general multiphase flow. The Strouhal number based on the jet conditions is an order lower than Sr = 0.2 indicating process variations rather than jet noise. Furthermore, at choking conditions the further expansion which occurs in single phase flow is likely different at multiphase flow. For non-choked flow, the standard can be adapted using multiphase mixture properties. This does lead to a good prediction. However at choked conditions, this method fails.

2007 ◽  
Author(s):  
Wenhong Liu ◽  
Liejin Guo ◽  
Ximin Zhang ◽  
Kai Lin ◽  
Long Yang ◽  
...  

Author(s):  
Suizheng Qiu ◽  
Minoru Takahashi ◽  
Guanghui Su ◽  
Dounan Jia

Water single-phase and nucleate boiling heat transfer were experimentally investigated in vertical annuli with narrow gaps. The experimental data about water single-phase flow and boiling two-phase flow heat transfer in narrow annular channel were accumulated by two test sections with the narrow gaps of 1.0mm and 1.5mm. Empirical correlations to predict the heat transfer of the single-phase flow and boiling two-phase flow in the narrow annular channel were obtained, which were arranged in the forms of the Dittus-Boelter for heat transfer coefficients in a single-phase flow and the Jens-Lottes formula for a boiling two-phase flow in normal tubes, respectively. The mechanism of the difference between the normal channel and narrow annular channel were also explored. From experimental results, it was found that the turbulent heat transfer coefficients in narrow gaps are nearly the same to the normal channel in the experimental range, and the transition Reynolds number from a laminar flow to a turbulent flow in narrow annuli was much lower than that in normal channel, whereas the boiling heat transfer in narrow annular gap was greatly enhanced compared with the normal channel.


Author(s):  
L. Wenhong ◽  
G. Liejin ◽  
Z. Ximin ◽  
L. Kai ◽  
Y. Long ◽  
...  

Author(s):  
Toshimichi Arai ◽  
Naoki Kudo ◽  
Tsuneaki Ishima ◽  
Ismail M. Youssef ◽  
Tomio Obokata ◽  
...  

Characteristics on particle motion in a liquid-solid two-phase jet flow were studied in the paper. The water jet including glass particle of 389 μm in mean diameter was injected into water bath. The experimental conditions were 0.21% of initial particle volume ratio, 5mm in pipe diameter and 1.84 m/s of mean velocity on outlet of the jet. A laser Doppler anemometer (LDA) with size discrimination was applied for measuring the time serious velocities of the single-phase flow, particle and water phase flow. A particle image velocimetry (PIV) was also applied in the two-phase flow. The normal PIV method can hardly measure the particle size and perform the particle size discrimination. In the experiment, using the gray scales related with the scattering light intensity, measuring method with size discrimination in two-phase flow was carried out. The experimental results show less difference between velocities of single-phase flow and water-phase flow under this low particle volume ratio condition. Particles have the relative motion with the water-phase and large rms velocity. The PIV used in this experiment, which is called multi-intensity-layer-PIV: MILP, can measure water-phase velocity with good accuracy.


Author(s):  
Jiang Nai-bin ◽  
Gao Li-xia ◽  
Huang Xuan ◽  
Zang Feng-gang ◽  
Xiong Fu-rui

In steam generators and other heat exchangers, there are a lot of tube bundles subjected to two-phase cross-flow. The fluctuating pressure on tube bundle caused by turbulence can induce structural vibration. The experimental data from a U-tube bundle of steam generator in air-water flow loop are analyzed in this work. The different upper bounds of buffeting force are used to calculate the turbulence buffeting response of U-tubes, and the calculation results are compared with the experimental results. The upper bounds of buffeting force include one upper bound based on single-phase flow, and two upper bounds based on two-phase flow. It is shown that the upper bound based on single-phase flow seriously underestimated the turbulence excitation, the calculated vibration response is much less than the experimental measurement. On the other hand, the vibration response results calculated with the upper bounds based on two-phase flow are closer to the measured results under most circumstances.


Author(s):  
Vasilios Kourakos ◽  
Sai¨d Chabane ◽  
Patrick Rambaud ◽  
Jean-Marie Buchlin

Safety devices are of major importance in the nuclear and chemical industry. Examples of such systems are safety valves and rupture disks. The behavior of this type of valve in single-phase flow (gas or liquid) has been described in detail in the literature, while for two-phase flow there is a lack of relative models since the phenomena are much more complex. The design and sizing of this apparatus is an important issue which would prevent its wrong functionality that could cause a hazardous situation. In this paper, a transparent (made in Polymethyl methacrylate) model of a safety valve is studied (1 1/2 in G 3 in); this has allowed full optical access and therefore the identification of the structure of the flow and the observation of the different phenomena occurring. Instead of a spring, used in an actual safety valve, the disk is fixed and its position can vary from completely closed to fully opened position. Thus, the static flow behavior of the valve is examined.


Author(s):  
Olivier Brunin ◽  
Geoffrey Deotto ◽  
Franck David ◽  
Joe¨l Pillet ◽  
Gilles Dague ◽  
...  

After a period of several years of operation, steam generators can be affected by fouling and clogging. Fouling means that deposits of sludge accumulate on tubes or tube support plates (TSP). That results in a reduction of heat exchange capabilities and can be modelled by means of a fouling factor. Clogging is a reduction of flow free area due to an accumulation of sludge in the space between TSP and tubes. The increase of the clogging ratio results in an increase of the overall TSP pressure loss coefficient. The link between the clogging ratio and the overall TSP pressure loss coefficient is the most important aspect of our capability to accurately calculate the thermal-hydraulics of clogged steam generators. The aim of the paper is to detail the experimental approach chosen by EDF and AREVA NP to address the calculation uncertainties. The calculation method is classically based on the computation of a single-phase (liquid-only) pressure loss coefficient, which is multiplied by a two-phase flow factor. Both parameters are well documented and can be derived on the basis of state of the art methods such as IDEL’CIK diagrams and CHISHOLM formula. The experimental approach consists of a validation of the correlations by performing tests on a mock-up section with an upward flow throughout a vertical array of tubes. A mixture of water and vapour refrigerant R116 is used to represent two-phase flows. The tube bundle is composed of a 25 tubes array in a square arrangement. The overall height of the mock-up is 2 m. Eight test TSPs were manufactured, considering eight different clogging configurations: six plates with a typical clogging profile at six clogging ratios (0, 44%, 58%, 72%, 86%, 95%), and two plates with a clogging ratio of 72% associated with two different clogging profiles (large bending radius profile and rectangular profile). A series of tests were performed in 2009 in single-phase flow conditions. Two-phase flow tests with a mixture of liquid water and vapour refrigerant R116 will be performed in 2010. The paper illustrates the main results obtained during the single-phase tests performed in 2009.


2021 ◽  
Vol 11 (5) ◽  
pp. 2020
Author(s):  
Thinh Quy Duc Pham ◽  
Jichan Jeon ◽  
Daeseong Jo ◽  
Sanghun Choi

This study aims to investigate the pressure changes, bubble dynamics, and flow physics inside the U- and C-shaped pipes with four different gravitational directions. The simulation is performed using a 1D centerline-based mesh generation technique along with a two-fluid model in the open-source software, OpenFOAM v.6. The continuity and momentum equations of the two-fluid model are discretized using the pressure-implicit method for the pressure-linked equation algorithm. The static and hydrostatic pressures in the two-phase flow were consistent with those of single-phase flow. The dynamic pressure in the two-phase flow was strongly influenced by the effect of the buoyancy force. In particular, if the direction of buoyancy force is the same as the flow direction, the dynamic pressure of the air phase increases, and that of the water phase decreases to satisfy the law of conservation of mass. Dean flows are observed on the transverse plane of the curve regions in both C-shaped and U-shaped pipes. The turbulent kinetic energy is stronger in a two-phase flow than in a single-phase flow. Using the 1D centerline-based mesh generation technique, we demonstrate the changes in pressure and the turbulent kinetic energy of the single- and two-phase flows, which could be observed in curve pipes.


Sign in / Sign up

Export Citation Format

Share Document