Load and structural health monitoring of a scaled CFRP rudder stock using electro-mechanical impedance technique

Author(s):  
Jochen Moll ◽  
Matthias Schmidt ◽  
Johannes Käsgen ◽  
Jörg Mehldau ◽  
Marcel Bücker ◽  
...  
2020 ◽  
pp. 147592172091712 ◽  
Author(s):  
Bárbara M Gianesini ◽  
Nicolás E Cortez ◽  
Rothschild A Antunes ◽  
Jozue Vieira Filho

Structural health monitoring systems are employed to evaluate the state of structures to detect damage, bringing economical and safety benefits. The electromechanical impedance technique is a promising damage detection tool since it evaluates structural integrity by only measuring the electrical impedance of piezoelectric transducers bonded to structures. However, in real-world applications, impedance-based damage detection systems exhibit strong temperature dependence; therefore, variations associated with temperature changes may be confused as damage. In this article, the temperature effect on the electrical impedance of piezoelectric ceramics attached to structures is analyzed. Besides, a new methodology to compensate for the temperature effect in the electromechanical impedance technique is proposed. The method is very general since it can be applied to nonlinear (polynomial) temperature and/or frequency dependences observed on the horizontal and vertical shifts of the impedance signatures. A computer algorithm that performs the compensation was developed, which can be easily incorporated into real-time damage detection systems. This compensation technique is applied successfully to two aluminum beams and one steel pipe, minimizing the effect of temperature variations on damage detection structural health monitoring systems in the temperature range from −40°C to 80°C and the frequency range from 10 to 90 kHz.


Sensors ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2805 ◽  
Author(s):  
Hamidreza Hoshyarmanesh ◽  
Mojtaba Ghodsi ◽  
Minjae Kim ◽  
Hyung Hee Cho ◽  
Hyung-Ho Park

Turbomachine components used in aerospace and power plant applications preferably require continuous structural health monitoring at various temperatures. The structural health of pristine and damaged superalloy compressor blades of a gas turbine engine was monitored using real electro-mechanical impedance of deposited thick film piezoelectric transducers at 20 and 200 °C. IVIUM impedance analyzer was implemented in laboratory conditions for damage detection in superalloy blades, while a custom-architected frequency-domain transceiver circuit was used for semi-field circumstances. Recorded electromechanical impedance signals at 20 and 200 °C acquired from two piezoelectric wafer active sensors bonded to an aluminum plate, near and far from the damage, were initially utilized for accuracy and reliability verification of the transceiver at temperatures >20 °C. Damage formation in both the aluminum plate and blades showed a peak shift in the swept frequency along with an increase in the amplitude and number of impedance peaks. The thermal energy at 200 °C, on the other hand, enforces a further subsequent peak shift in the impedance signal to pristine and damaged parts such that the anti-resonance frequency keeps reducing as the temperature increases. The results obtained from the impedance signals of both piezoelectric wafers and piezo-films, revealed that increasing the temperature somewhat decreased the real impedance amplitude and the number of anti-resonance peaks, which is due to an increase in permittivity and capacitance of piezo-sensors. A trend is also presented for artificial intelligence training purposes to distinguish the effect of the temperature versus damage formation in sample turbine compressor blades. Implementation of such a monitoring system provides a distinct advantage to enhance the safety and functionality of critical aerospace components working at high temperatures subjected to crack, wear, hot-corrosion and erosion.


2014 ◽  
Vol 116 ◽  
pp. 147-164 ◽  
Author(s):  
Naserodin Sepehry ◽  
Firooz Bakhtiari-Nejad ◽  
Mahnaz Shamshirsaz

Author(s):  
Liuxian Zhao ◽  
Lingyu Yu ◽  
Mattieu Gresil ◽  
Michael Sutton ◽  
Siming Guo

Electromechanical impedance (EMI) method is an effective and powerful technique in structural health monitoring (SHM) which couples the mechanical impedance of host structure with the electrical impedance measured at the piezoelectric wafer active sensor (PWAS) transducer terminals. Due to the electromechanical coupling in piezoelectric materials, changes in structural mechanical impedance are reflected in the electrical impedance measured at the PWAS. Therefore, the structural mechanical resonances are reflected in a virtually identical spectrum of peaks and valleys in the real part of the measured EMI. Multi-physics based finite element method (MP-FEM) has been widely used for the analysis of piezoelectric materials and structures. It uses finite elements taking both electrical and mechanical DOF’s into consideration, which allows good differentiation of complicated structural geometries and damaged areas. In this paper, MP-FEM was then used to simulate PWAS EMI for the goal of SHM. EMI of free PWAS was first simulated and compared with experimental result. Then the constrained PWAS was studied. EMI of both metallic and glass fiber composite materials were simulated. The first case is the constrained PWAS on aluminum beam with various dimensions. The second case studies the sensitivity range of the EMI approach for damage detection on aluminum beam using a set of specimens with cracks at different locations. In the third case, structural damping effects were also studied in this paper.. Our results have also shown that the imaginary part of the impedance and admittance can be used for sensor self-diagnosis.


Sign in / Sign up

Export Citation Format

Share Document