Image quality in pseudophakic eyes with two different types of intraocular lenses ranging in the degree of high myopia

1997 ◽  
Vol 2 (4) ◽  
pp. 375
Author(s):  
Eloy-Angel Villegas-Ruiz
Author(s):  
Hyeck Soo Son ◽  
Jung Min Lee ◽  
Ramin Khoramnia ◽  
Chul Young Choi

Abstract Purpose To analyse and compare the surface topography and roughness of three different types of diffractive multifocal IOLs. Methods Using scanning electron microscope (SEM, Inspect F, 5.0 KV, maximum magnification up to 20,000) and atomic force microscope (AFM, Park Systems, XE-100, non-contact, area profile comparison, 10 × 10 µm, 40 × 40 µm), the surface quality of the following diffractive IOLs was studied: the AcrySof IQ PanOptix (Alcon, USA), the AT LARA 829MP (Carl Zeiss Meditec, Germany), and Tecnis Symfony (Johnson&Johnson Vision, USA). The measurements were made over three representative areas (central non-diffractive optic, central diffractive optic, and diffractive step) of each IOL. Roughness profile in terms of mean arithmetic roughness (Ra) and root-mean-squared roughness (Rq) values were obtained and compared statistically. Results In SEM examination, all IOLs showed a smooth optical surface without any irregularities at low magnification. At higher magnification, Tecnis Symfony showed unique highly regular, concentric, and lineate structures in the diffractive optic area which could not be seen in the other studied diffractive IOLs. The differences in the measured Ra and Rq values of the Tecnis Symfony were statistically significant compared to the other models (p < 0.05). Conclusion Various different topographical traits were observed in three diffractive multifocal IOLs. The Ra values of all studied IOLs were within an acceptable range. Tecnis Symfony showed statistically significant higher surface Ra values at both central diffractive optic and diffractive step areas. Furthermore, compared to its counterparts, Tecnis Symfony demonstrated highly ordered, concentric pattern in its diffractive surfaces.


2019 ◽  
Vol 48 (8) ◽  
pp. 20190139
Author(s):  
Emine Şebnem Kursun-Cakmak ◽  
Husniye Demirturk Kocasarac ◽  
Seval Bayrak ◽  
Gülbahar Ustaoğlu ◽  
Marcel Noujeim

Objectives: To assess the contrast-to-noise ratio (CNR) of four different types of dental implant materials in CT and cone beam CT (CBCT) images with varying scan settings. Methods: Four different types of implants: zirconium (Zr), titanium (Ti) Grade 4 and 5 and titanium–zirconium (Ti–ZrO2) alloy were placed in a 3% gelatin phantom in a cylindrical plastic container and scanned with two different CT machines (GE Medical systems and Toshiba Medical Systems) and one CBCT machine (I-CAT, Imaging Sciences International) with different voxel sizes of 0.2, 0.25, 0.3 and 0.4 mm. Images were analyzed using ImageJ software with the purpose of estimating the CNR. Results: The CNR obtained from images acquired with CT was lower than the CBCT with all voxel sizes tested. 0.3 and 0.4 mm voxel sizes exhibited the highest CNR (p < 0.05) that gives the best image quality. Among the implant materials tested, titanium Grade 5 has the highest levels of CNR while Zirconium has the lowest (p < 0.05). Conclusions: The optimum protocol for radiographic follow-up in areas near implants on the I-CAT is low-resolution settings (0.3 and 0.4 mm voxel sizes) which gave the highest CNR thus image quality. In presence of Zr implants, an alternative imaging modality (i.e., MRI) may be considered to avoid low-quality images.


Medicina ◽  
2021 ◽  
Vol 57 (4) ◽  
pp. 319
Author(s):  
Ivajlo Popov ◽  
Veronika Popova ◽  
Juraj Sekac ◽  
Vladimir Krasnik

Background and Objectives: To evaluate the performance of intraocular lenses (IOLs) using power calculation formulas on different types of IOL. Materials and Methods: 120 eyes and four IOL types (BioLine Yellow Accurate Aspheric IOL (i-Medical), TECNIS ZCB00, TECNIS ZA9003 (Johnson & Johnson) (3-piece IOL) and Softec HD (Lenstec)) were analyzed. The performance of Haigis, Barret Universal II and SKR-II formulas were compared between IOL types. The mean prediction error (ME) and mean absolute prediction error (MAE) were analyzed. Results: The overall percentage of eyes predicted within ±0.25 diopters (D) was 40.8% for Barret; 39.2% Haigis and 31.7% for SRK-II. Barret and Haigis had a significantly lower MAE than SRK-II (p < 0.05). The results differed among IOL types. The largest portion of eyes predicted within ±0.25 D was with the Barret formula in ZCB00 (33.3%) and ZA9003 (43.3%). Haigis was the most accurate in Softec HD (50%) and SRK-II in Biolline Yellow IOL (50%). ZCB00 showed a clinically significant hypermetropic ME compared to other IOLs. Conclusions: In general, Barret formulas had the best performance as a universal formula. However, the formula should be chosen according to the type of IOL in order to obtain the best results. Constant optimizations are necessary for the Tecnis IOL ZCB00 and ZA9003, as all of the analyzed formulas achieved a clinically significant poor performance in this type of IOL. ZCB00 also showed a hypermetropic shift in ME in all the formulas.


Ophthalmology ◽  
2001 ◽  
Vol 108 (1) ◽  
pp. 90-99 ◽  
Author(s):  
Ignacio Jiménez-Alfaro ◽  
José M Benı́tez del Castillo ◽  
Julian Garcı́a-Feijoó ◽  
Javier G Gil de Bernabé ◽  
José M Serrano de la Iglesia

2002 ◽  
Vol 28 (1) ◽  
pp. 95-99 ◽  
Author(s):  
Carole Burillon ◽  
Laurent Kodjikian ◽  
Gérard Pellon ◽  
Annie Martra ◽  
Jean Freney ◽  
...  

2016 ◽  
Vol 32 (6) ◽  
pp. 725-733 ◽  
Author(s):  
Maja Bohac ◽  
Marija Anticic ◽  
Natasa Draca ◽  
Bojan Kozomara ◽  
Iva Dekaris ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document