Microparticle impact detector experiment on MightySat I

1997 ◽  
Author(s):  
Patrick J. Serna ◽  
Gary H. Liechty ◽  
Craig L. Neslen ◽  
Renzo Del Frate ◽  
Edwin Draper
1998 ◽  
Author(s):  
Patrick J. Serna ◽  
Gary H. Liechty ◽  
Craig L. Neslen ◽  
Renzo Del Frate ◽  
Edwin Draper

1994 ◽  
Author(s):  
John P. Oliver ◽  
Charles G. Simon ◽  
William J. Cooke ◽  
S. F. Singer ◽  
Jerry L. Weinberg ◽  
...  

1980 ◽  
pp. 163-174 ◽  
Author(s):  
W. Barth ◽  
N. Fessler-Wilhelmi ◽  
W. Lehmann ◽  
P. Turowski
Keyword(s):  

2006 ◽  
Vol 981 ◽  
Author(s):  
Ildar Sabirianov ◽  
Robert W Fairchild ◽  
Jennifer I Brand

AbstractBoron carbide diode detectors, fabricated from two different polytypes of semiconducting boron carbide, will detect neutrons in reasonable agreement with theoretical expectations. The performance of the all boron carbide neutron detector differs, as expected, from devices where a boron rich neutron capture layer is distinct from the diode charge collection region (i.e. a conversion layer solid state detector).Diodes were fabricated from natural abundance boron (20% 10B and 80% 11B.) directly on the metal substrates and metal contacts applied to the films as grown. The total boron depth was on the order of 2 microns. This is clearly not a conversion-layer configuration. The diodes were exposed to thermal neutrons generated from a paraffin moderated plutonium-beryllium source in moderated and unmoderated, as well as shielded and unshielded experimental configurations, where the expected energy peaks at at 2.31 MeV and 2.8 MeV were clearly observed, albeit with some incomplete charge collection typical of thinner diode structures. The results are compared with other boron based thin film detectors and literature models.


1988 ◽  
Vol 01 (11n12) ◽  
pp. 431-435 ◽  
Author(s):  
CHANGXIN FAN ◽  
LIANGKAI YU

The V-I characteristics of Y-Ba-Cu-O device is different from that of conventional low Tc Josephson junction. This enables us to use the small critical current device as an electromagnetic radiation detector. Experiment shows that the smaller the critical current is, the greater the dynamic resistance and the higher the voltage responsibility to radiation power. When the critical current is adjusted down to zero but the V-I curve is still obviously nonlinear, the device will have highest responsibility.


Science ◽  
2011 ◽  
Vol 334 (6059) ◽  
pp. 1058-1058 ◽  
Author(s):  
I. G. Mitrofanov ◽  
W. V. Boynton ◽  
M. L. Litvak ◽  
A. B. Sanin ◽  
R. D. Starr

Sign in / Sign up

Export Citation Format

Share Document