X-ray phase-contrast imaging study of soft tissue and bone samples

Author(s):  
Dachao Gao ◽  
Andrew Pogany ◽  
Andrew W. Stevenson ◽  
Timur E. Gureyev ◽  
Stephen W. Wilkins
Author(s):  
Christian Kottler ◽  
Vincent Revol ◽  
Rolf Kaufmann ◽  
Caroline Maake ◽  
Stefan Stubinger ◽  
...  

1995 ◽  
Vol 48 (1) ◽  
pp. 103 ◽  
Author(s):  
Dachao Gao ◽  
Timothy J Davis ◽  
Stephen W Wilkins

We report X-ray phase-contrast images of voids and glass fibres in a polymer matrix. The phase-contrast images are obtained using both a monolithic 3-refiection asymmetric channel-cut monochromator and analyser with 1�54 A X-rays. The mechanisms of contrast formation in the images of voids and glass fibres are discussed in detail and numerical simulations of the images are found to agree with the experiments.


Author(s):  
Massimo Marenzana ◽  
Charlotte K. Hagen ◽  
Patricia Das Neves Borges ◽  
Marco Endrizzi ◽  
Magdalena B. Szafraniec ◽  
...  

The mouse model of osteoarthritis (OA) has been recognized as the most promising research tool for the identification of new OA therapeutic targets. However, this model is currently limited by poor throughput, dependent on the extremely time-consuming histopathology assessment of the articular cartilage (AC). We have recently shown that AC in the rat tibia can be imaged both in air and in saline solution using a laboratory system based on coded-aperture X-ray phase-contrast imaging (CAXPCi). Here, we explore ways to extend the methodology for imaging the much thinner AC of the mouse, by means of gold-standard synchrotron-based phase-contrast methods. Specifically, we have used analyser-based phase-contrast micro-computed tomography (micro-CT) for its high sensitivity to faint phase changes, coupled with a high-resolution (4.5 μm pixel) detector. Healthy, diseased (four weeks post induction of OA) and artificially damaged mouse AC was imaged at the Elettra synchrotron in Trieste, Italy, using the above method. For validation, we used conventional micro-CT combined with radiopaque soft-tissue staining and standard histomorphometry. We show that mouse cartilage can be visualized correctly by means of the synchrotron method. This suggests that: (i) further developments of the laboratory-based CAXPCi system, especially in terms of pushing the resolution limits, might have the potential to resolve mouse AC ex vivo and (ii) additional improvements may lead to a new generation of CAXPCi micro-CT scanners which could be used for in vivo longitudinal pre-clinical imaging of soft tissue at resolutions impossible to achieve by current MRI technology.


2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Author(s):  
Jianheng Huang ◽  
Yaohu Lei ◽  
Xin Liu ◽  
Jinchuan Guo ◽  
Ji Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document