Energy-dependent quantum detective efficiency (QDE) measurements of a photon-counting CdTe detector array used for the scanning-beam digital x-ray (SBDX) system

Author(s):  
Koji Iwata ◽  
Josh M. Star-Lack ◽  
Edward G. Solomon ◽  
Joseph A. Heanue ◽  
Rick E. Walkup ◽  
...  
1999 ◽  
Author(s):  
Joseph A. Heanue ◽  
David A. Pearson ◽  
Robert E. Melen

2019 ◽  
Vol 26 (4) ◽  
pp. 922-930 ◽  
Author(s):  
Joshua L. Dickerson ◽  
Elspeth F. Garman

Using X-ray energies higher than those normally used (5–15 keV) for macromolecular X-ray crystallography (MX) at synchrotron sources can theoretically increase the achievable signal as a function of dose and reduce the rate of radiation damage. In practice, a major stumbling block to the use of higher X-ray energy has been the reduced quantum efficiency of silicon detectors as the X-ray energy increases, but hybrid photon-counting CdTe detectors are optimized for higher X-ray energies, and their performance has been steadily improving. Here the potential advantages of using higher incident beam energy together with a CdTe detector for MX are explored, with a particular focus on the advantages that higher beam energies may have for MX experiments with microbeams or microcrystals. Monte Carlo simulations are presented here which for the first time include the efficiency responses of some available X-ray detectors, as well as the possible escape of photoelectrons from the sample and their entry from surrounding material. The results reveal a `sweet spot' at an incident X-ray energy of 26 keV, and show a greater than factor of two improvement in diffraction efficiency at this energy when using microbeams and microcrystals of 5 µm or less.


2021 ◽  
Vol 16 (12) ◽  
pp. C12027
Author(s):  
A. Krzyzanowska

Abstract Hybrid pixel radiation detectors working in a single-photon counting mode have gained increasing attention due to their noiseless imaging and high dynamic range. Due to the fact that sensors of different materials can be attached to the readout circuit, they allow operation with a wide range of photon energies. The performance of the single photon counting detectors is limited by pile-up. To allow a detector to work under high flux conditions, the pixel size is reduced, which minimizes detector dead time. However, with smaller pixel sizes the charge sharing effect, a phenomenon that deteriorates both detection efficiency and spatial resolution is more profound. The influence of charge sharing on the detector performance can be quantified using parameterization of the s-curve obtained in the spectral response measurements. The article presents the measurements of the response function of a hybrid pixelated photon counting detector for certain primary energy, which corresponds to the probability of detecting a photon as a function of its energy deposition. The measurements were carried out using an X-ray tube by performing a threshold scan during illumination with X-ray photons of a 1.5 mm and 0.75 mm thick CdTe detector with 100 µm pixel pitch. The charge size cloud depends on the sensor material, the bias voltage, and the sensor thickness. Therefore, the experimental data from a sensor biased with different bias voltages are compared to the theoretical results based on a cascaded model of a single-photon counting segmented silicon detector. The study of the charge sharing influence on the spatial resolution of the CdTe detector will serve for a further study of the possible implementations of the algorithms achieving subpixel resolution, in which the charge sharing becomes the desired effect since the charge division in the pixels is used to interpolate the photon interaction position.


Sign in / Sign up

Export Citation Format

Share Document